Sign In
Upload
Manuals
Brands
Lamtec Manuals
Transmitter
LS2
Lamtec LS2 Manuals
Manuals and User Guides for Lamtec LS2. We have
2
Lamtec LS2 manuals available for free PDF download: User Manual
Lamtec LS2 User Manual (58 pages)
Transmitter, Probe
Brand:
Lamtec
| Category:
Transmitter
| Size: 3 MB
Table of Contents
Table of Contents
3
1 General Information
5
Validity of These Instructions
5
2 Safety
6
Explanation of the Symbols in the Safety Notes
6
Proper Use - Conditions of Use
7
Permissible Users
8
Safety Equipment/Safety Measures
9
Protection against Emissions from Gas Carrying Channels
9
Important Notes on Shutdown/Return to Service
10
Environmental Protection, Waste Disposal
10
3 Overview
11
System Overview
11
Brief Description
12
4 Technical Description
13
Advantages of the Measurement Principle
13
LT2 Lambda Transmitter
14
LT2 Lambda Transmitter in Wall Mounting Case
14
Cold-Start Delay
15
Options
16
Display and Operating Unit Type 657R0831
16
Remote Display Software
17
Calculation of Combustion Efficiency
18
Calculation of the CO 2 Concentration
18
Firing Rate Dependent and Fuel Specific Limit Values/Limit Curves
19
Analogue Output (0/4
19
5 Lamtec System Bus (Lsb)
20
Jumpers, LED, Fuses and Terminals
20
Function
20
6 Commissioning/Decommissioning
21
Preliminary Works
21
The LT2 Lambda Transmitter's Display and Operating Elements
21
Monitor Output
21
Internal Display and Operating Elements
22
Decommissioning
23
Return to Service
23
Measurement Start-Up
26
Install the Probe in the PIF and Align the GED
28
Setting up Service Warnings
30
7 Operation
31
Operation/Measurement Value Display
31
Measurement Value
31
Commands
32
Status Signals
32
Operating Parameters
32
General Instructions for Operation
33
Measurement During Distinct Pressure Surges at the Measuring Site
33
Operational Failure, Switching on and off
33
Liquid Purification
33
8 Service and Maintenance
34
Checking the O 2 Probe
34
Checking the Air Voltage
34
Checking by Counter Measurement
36
Checking the LT2
37
Checking the Lt2'S Measuring Input
37
Maintenance
37
Consumables
37
9 Faults/Warnings
38
Faults
38
Warnings
39
Resetting Faults/Warnings
40
Faults - Causes and Solutions
41
9.3.1.1 Probe Voltage too Low
41
9.3.1.2 Defective LS2 Probe Heating
41
9.3.1.3 Broken Wire Probe/Defective Probe
41
9.3.1.4 no Probe Dynamics
42
9.3.1.5 Fault Analogue Output
42
O 2 Value Is Incorrect
42
Warnings - Causes and Solutions
43
LS2 Internal Resistance too High
43
Offset Voltage to Air Invalid
43
Analogue Inputs 1/2/3/4 Input Value too Large/Too Small
43
Configuration Error at Analogue Outputs
43
Service Warning 1/Service Warning 2
43
10 Spare Parts
44
LT2 Spare Parts
44
Spare Parts Lambda Probe LS2 in Housing
44
Spare Parts LS2-HT Lambda Probe
45
11 Appendix
46
Technical Data LT2 Lambda Transmitter
46
Technical Data LT2 in Wall Mounting Housing
46
Technical Data LS2 Lambda Probe
48
Technical Data LS2-HT Lambda Probe
50
Terminal Assignment Terminal Socket for Probe HT
52
Electric Connections Device Side
53
Jumpers
53
DIP Switch
53
Fuses
53
LT2 Power Electronic Type 657E1882
54
Wet/Dry Measurement Deviations, Conversion Table
55
12 Declaration of Conformity
56
Advertisement
Lamtec LS2 User Manual (58 pages)
Lambda Transmitter, Lambda Probe
Brand:
Lamtec
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Important Information about the Manual
5
Validity of These Instructions
5
Information on Using this Operating Manual
5
2 General Safety Instructions
6
Classification of the Safety Instructions and Warnings
6
Proper Use - Conditions of Use
7
Permissible Users
8
Safety Equipment/Safety Measures
9
3 Product Description
11
Design and Accessory LS2 Lambda Probe
11
4 Display and Operational Controls
13
Operation
14
Menu Structure
14
Password Entry Menu Structure
14
Information Menu Structure
15
Calibration Menu Structure
15
Settings Menu Structure
16
Status Line
17
Main Menu
18
Main Menu - Information
19
Main Menu - Calibration
19
Main Menu - Settings
20
5 Maintenance
21
Probe Testing and Calibration
21
Checking/Calibrating the Air Voltage (Offset)
21
Checking/Calibrating the O 2 Electrode
21
Reading the Measured Values
21
Enter the Password for the Access Level
23
Activate/Deactivate Maintenance Mode
24
Response of the Internal Resistance Regulation
25
Premature Cold Start Termination
26
Calibrating the Probe
27
5.1.8.1 Offset Calibration Perform to 21 % O
28
O 2 Calibrating in the Operating Point with Reference Measurement
30
Checking/Calibrating with Test Gas
31
Checking/Calibrating with Reference Measurement
34
Consumables
34
Settings
35
5.1.12.1 Maintenance Mode
35
5.1.12.2 Filter Time
35
5.1.12.3 Analogue Outputs
35
5.1.12.4 Display
36
Limit Values
37
6 Correcting Faults
38
Faults and Warnings
38
Faults
38
Warnings
41
Call of the Fault History
42
7 Decommissioning
43
Protection against Emissions from Gas Carrying Channels
43
8 Options
44
Analogue Outputs Via LSB Module Current, Alternative Voltage, LSB Address 19
44
Functional Description
44
Factory Setting of Analogue Outputs Via LSB Module
45
Conversion of the Output Range Via the User Interface
46
Digital Outputs Via LSB Module, LSB Address 03 and 51
47
Functional Description
47
Factory Setting of the Digital Outputs
48
Diagnosis of the Digital Outputs
48
Digital Inputs Via the LSB Module, LSB Address 11 and 55
49
Functional Description
49
Factory Settings of the Digital Inputs
50
Diagnosis of the Digital Inputs
50
LSB Module for Calculating Combustion Efficiency
51
Functional Description
51
9 Storage
53
Storage Conditions
53
10 Disposal Notes
54
Environmental Protection, Waste Disposal
54
11 Appendix
55
Wet/Dry Measurement Deviations, Conversion Table
55
EU Declaration of Conformity
56
Advertisement
Related Products
Lamtec LT2
Lamtec LT3-F
Lamtec Lambda LS2-K
Lamtec Lambda LT2-K
Lamtec Lambda LS2KV
Lamtec LT3
Lamtec LT1
Lamtec KS1-DK
Lamtec KS1D
Lamtec Categories
Control Unit
Controller
Transmitter
Industrial Equipment
Control Systems
More Lamtec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL