Sign In
Upload
Manuals
Brands
Keysight Technologies Manuals
Power Supply
E36103B
Keysight Technologies E36103B Manuals
Manuals and User Guides for Keysight Technologies E36103B. We have
1
Keysight Technologies E36103B manual available for free PDF download: Operating And Service Manual
Keysight Technologies E36103B Operating And Service Manual (93 pages)
Programmable DC Power Supplies
Brand:
Keysight Technologies
| Category:
Power Supply
| Size: 2.49 MB
Table of Contents
Table of Contents
2
Notices
6
Copyright Notice
6
Manual Part Number
6
Edition
6
Published by
6
Warranty
6
Technology Licenses
6
U.S. Government Rights
7
Waste Electrical and Electronic Equipment (WEEE)
7
Declarations of Conformity
7
Safety Information
8
Safety and Regulatory Information
9
Safety Considerations
9
Safety Symbols
10
Regulatory Markings
11
South Korean Class a EMC Declaration
11
Safety and EMC Requirements
11
Environmental Conditions
12
Getting Started
13
Introduction
14
Front Panel
14
Rear Panel
15
Display
16
Dimension Diagram
17
Setup the Instrument
17
Options and Fuse Information
18
Ensure the Correct AC Input Voltage and Fuse Settings
18
Programming Ranges
20
Table of Programming and Readback Resolutions
20
Extending the Voltage Range and Current Range
21
Series Connections
21
Parallel Connections
21
Front Panel Operation
22
Configure the LAN Interface
22
Set Voltage and Current
23
Specify 2- or 4-Wire Measurement
23
Configure Overcurrent Protection (OCP) and Overvoltage Protection (OVP)
24
Clear an OCP or OVP Event
24
Clear an Overtemperature Protection (OTP) Event
25
Lock and Unlock the Front Panel
25
Save or Recall the Instrument's State
26
Configure the Power-On State
26
Read Error Codes
26
Remote Control
27
Keysight IO Libraries Suite
27
E36100B Series Web Interface
27
Technical Connection Details
29
Rack Mounting the Instrument
30
Rack Mounting a Single Instrument
30
Rack Mounting Multiple Instruments Side-By-Side
30
SCPI Programming
32
Introduction to the SCPI Language
33
Command Format Used in this Manual
34
Command Separators
35
Using the MIN and MAX Parameters
35
Querying Parameter Settings
35
SCPI Command Terminators
36
IEEE-488.2 Common Commands
36
SCPI Parameter Types
36
Error Messages
38
Error Codes
38
SCPI Status Registers
42
What Is an Event Register
42
What Is an Enable Register
42
Standard Event Status Enable Register
43
Operation Status Register
43
Questionable Register
43
Apply Subsystem
45
Apply <Voltage>| Default | Minimum | Maximum[,<Current>| Default | Minimum | Maximum]Apply
45
Calibration Subsystem
46
Calibration:count
46
Calibration:current[:Data][:High] <Value
46
Calibration:current[:Data]:Low <Value
46
Calibration:current:level[:High] Minimum|Maximum
46
Calibration:current:level:low Minimum|Maximum
46
Calibration:state <State>,<Code>Calibration:state
46
Calibration:string "<String>"Calibration:string
47
Calibration:voltage[:Data] <Value
47
Calibration:voltage:level Minimum|Maximum
47
Current Subsystem
48
[Source:]Current[:Level][:Immediate][:Amplitude] <Current> | Minimum | Maximum | up | down [Source:]Current[:Level][:Immediate][:Amplitude]? [Minimum | Maximum]
48
[Source:]Current[:Level][:Immediate]:Step[:Increment] <Current> | Default[Source:]Current[:Level] [:Immediate]:Step[:Increment]? [Default]
48
[Source:]Current[:Level]:Triggered[:Amplitude] <Current> | Minimum | Maximum[Source:]Current [:Level]:Triggered[:Amplitude]? [Minimum | Maximum]
48
[Source:]Current:protection:clear
48
[Source:]Current:protection:delay[:Time] <Time> | Minimum | Maximum [Source:]Current:protection:delay[:Time]? [Minimum | Maximum]
48
[Source:]Current:protection:state On|1|Off|0[Source:]Current:protection:state
48
[Source:]Current:protection:tripped
48
Display Subsystem
49
Display[:Window]:Text:clear
49
Display[:Window]:Text[:Data] "<String>"Display[:Window]:Text[:Data]
49
Display[:Window][:State] on | 1 | off | 0Display[:Window][:State]
49
IEEE-488 Subsystem
50
Cls
50
ESE <Enable Value>*Ese
50
Esr
50
Idn
50
Opc*Opc
51
Opt
51
Psc 0|1*Psc
51
Rst
51
RCL <State>*Sav <State
51
SRE <Enable Value>*Sre
52
Stb
52
Trg
52
Tst
52
Wai
52
Measure Subsystem
53
Measure:current[:DC]
53
Measure[:Voltage][:DC]
53
Output Subsystem
54
Output[:State] on | 1 | off | 0Output[:State]
54
Output:protection:clear
54
Output:pon:state Rst|Rcl0|Rcl1|Rcl2|Rcl3|Rcl4|Rcl5|Rcl6|Rcl7|Rcl8|Rcl9|Output:pon:state
54
Status Subsystem
55
Status:operation:[Event]
55
Status:operation:condition
55
Status:operation:enable <Value
55
Status:preset
55
Status:questionable:condition
55
Status:questionable:enable <Enable Value>Status:questionable:enable
56
Status:questionable[:Event]
56
System Subsystem
57
System:error[:Next]
57
System:local
57
System:remote
57
System:rwlock
58
System:security:immediate
58
System:version
58
Triggering Commands
59
Abort
59
Initiate[:Immediate]
59
Initiate:continuous on | 1 | off | 0Initiate:continuous
59
Trg
59
Trigger[:Sequence]:Delay <Seconds> Minimum | Maximumtrigger[:Sequence]:Delay? [Minimum | Maximum]
59
Trigger[:Sequence]:Source BUS | Immediatetrigger[:Sequence]:Source
59
Voltage Subsystem
60
[Source:]Voltage[:Level][:Immediate][:Amplitude] <Voltage>|Minimum|Maximum|Default [Source:]Voltage[:Level][:Immediate][:Amplitude]? [Minimum | Maximum]
60
[Source:]Voltage[:Level][:Immediate]:Step[:Increment] <Numeric Value>|Default[Source:]Voltage [:Level][:Immediate]:Step[:Increment]? [Default]
60
[Source:]Voltage[:Level]:Triggered[:Amplitude] <Voltage>|Min|Max[Source:]Voltage[:Level]:Triggered [:Amplitude]? [MIN|MAX]
60
[Source:]Voltage:protection:clear
60
[Source:]Voltage:protection:state On|1|Off|0[Source:]Voltage:protection:state
60
[Source:]Voltage:protection:tripped
60
[Source:]Voltage:protection[:Level] <Voltage>|Minimum | Maximum[Source:]Voltage:protection [:Level]? [Minimum|Maximum]
60
[Source:]Voltage:sense[:Source] Internal | External
61
Service and Support
62
Service and Repair
63
Types of Service Available
63
Cleaning and Handling
63
Troubleshooting
64
Self-Test Procedures
65
To Replace the Power-Line Fuse
65
User Replaceable Parts
65
Performance Verification
66
Recommended Test Equipment
66
Test Considerations
66
Measurement Techniques
67
Setup for most Tests
67
Constant Voltage (CV) Verification
68
Constant Current (CC) Verification
75
Test Record Forms
78
Test Record Form - Keysight E36102B
78
Test Record Form - Keysight E36103B
80
Test Record Form - Keysight E36104B
82
Test Record Form - Keysight E36105B
84
Test Record Form - Keysight E36106B
86
Calibration Adjustment Procedures
88
Closed-Case Electronic Calibration
88
Calibration Interval
88
Calibration Adjustment Process
88
Calibration Security
89
Calibration Count
90
Calibration Message
90
Saving Calibration Data
90
Calibration Auto Save
90
Calibration Procedure
90
Save the Calibration Data
92
Specifications and Typical Characteristics
92
Advertisement
Advertisement
Related Products
Keysight Technologies E36100 Series
Keysight Technologies E36100B Series
Keysight Technologies E36102B
Keysight Technologies E36104B
Keysight Technologies E36105B
Keysight Technologies E36106B
Keysight Technologies E36150 Series
Keysight Technologies E36154A
Keysight Technologies E36155A
Keysight Technologies E3644A
Keysight Technologies Categories
Measuring Instruments
Test Equipment
Control Unit
Portable Generator
Power Supply
More Keysight Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL