Sign In
Upload
Manuals
Brands
Keysight Technologies Manuals
Power Supply
E36100 Series
Keysight Technologies E36100 Series Manuals
Manuals and User Guides for Keysight Technologies E36100 Series. We have
1
Keysight Technologies E36100 Series manual available for free PDF download: Operating And Service Manual
Keysight Technologies E36100 Series Operating And Service Manual (102 pages)
Brand:
Keysight Technologies
| Category:
Power Supply
| Size: 4.04 MB
Table of Contents
Table of Contents
3
Notices
9
Copyright Notice
9
Manual Part Number
9
Edition
9
Published by
9
Warranty
9
Technology Licenses
9
U.S. Government Rights
10
Waste Electrical and Electronic Equipment (WEEE)
10
Declarations of Conformity
11
Safety Information
11
Safety and Regulatory Information
12
Safety Considerations
12
Before Applying Power
12
Ground the Instrument
12
Do Not Operate in an Explosive Atmosphere or Wet Environments
12
Do Not Operate Damaged or Defective Instruments
13
Do Not Substitute Parts or Modify Instrument
13
Be Cautious When Dealing with Outputs above 60 VDC
13
Use the Power Cord Provided
13
Use the Device as Specified
13
Clean with Slightly Dampened Cloth
14
Do Not Block Ventilation Holes
14
Observe All Device Markings before Connecting to Device
14
Turn Device off before Connecting to Output Terminals
14
Ensure Cover Is Secured in Place
14
Safety Symbols
15
Regulatory Markings
16
South Korean Class a EMC Declaration
16
Safety and EMC Requirements
17
1 Getting Started
19
Introduction
20
Front Panel
21
Rear Panel
22
Display
23
To Set up the Instrument
23
Options and Fuse Information
25
Ensure the Correct AC Input Voltage and Fuse Settings
25
Use the Proper Switch Settings
25
Use the Correct Fuse
26
Programming Ranges
27
Table of Programming and Readback Resolutions
27
Extending the Voltage Range and Current Range
28
Series Connections
28
Parallel Connections
28
Front-Panel Operation
29
Configure the LAN Interface
29
Set Voltage and Current
30
Constant Voltage and Constant Current
30
Specify 2- or 4-Wire Measurement
30
Configure Overcurrent Protection (OCP) and Overvoltage Protection (OVP)
31
Clear an OCP or OVP Event
31
Clear an Overtemperature Protection (OTP) Event
32
Lock and Unlock the Front Panel
32
Save or Recall the Instrument's State
33
To Save or Recall the Instrument State
33
Configure the Power-On State
33
Read Error Codes
34
Remote Control
35
Keysight IO Libraries Suite
35
E36100 Series Web Interface
35
Technical Connection Details
38
2 SCPI Programming
40
Introduction to the SCPI Language
41
Command Format Used in this Manual
42
Command Separators
43
Using the MIN and MAX Parameters
43
Querying Parameter Settings
44
SCPI Command Terminators
44
IEEE-488.2 Common Commands
44
SCPI Parameter Types
45
Numeric Parameters
45
Discrete Parameters
45
Boolean Parameters
45
String Parameters
45
Error Messages
46
Error Codes
46
SCPI Status Registers
50
What Is an Event Register
50
What Is an Enable Register
50
Standard Event Status Enable Register
51
Operation Status Register
51
Questionable Register
51
Apply Subsystem
53
Apply <Voltage>| Default | Minimum | Maximum[,<Current>| Default | Minimum | Maximum] Apply
53
Calibration Subsystem
54
Calibration:count
54
Calibration:current[:Data][:High] <Value
54
Calibration:current[:Data]:Low <Value
54
Calibration:current:level[:High] Minimum|Maximum
54
Calibration:current:level:low Minimum|Maximum
54
Calibration:state <State>,<Code>Calibration:state
55
Calibration:string "<String>"Calibration:string
55
Calibration:voltage[:Data] <Value
55
Calibration:voltage:level Minimum|Maximum
55
Current Subsystem
56
[Source:]Current[:Level][:Immediate][:Amplitude] <Current> | Minimum | Maximum | up | down [Source:]Current[:Level][:Immediate][:Amplitude]? [Minimum | Maximum]
56
[Source:]Current[:Level][:Immediate]:Step[:Increment] <Current> | Default[Source:]Current [:Level][:Immediate]:Step[:Increment]? [Default]
56
[Source:]Current[:Level]:Triggered[:Amplitude] <Current> | Minimum | Maximum [Source:]Current[:Level]:Triggered[:Amplitude]? [Minimum | Maximum]
56
[Source:]Current:protection:clear
56
[Source:]Current:protection:delay[:Time] <Time> | Minimum | Maximum [Source:]Current:protection:delay[:Time]? [Minimum | Maximum]
56
[Source:]Current:protection:state On|1|Off|0[Source:]Current:protection:state
56
[Source:]Current:protection:tripped
57
Display Subsystem
58
Display[:Window]:Text:clear
58
Display[:Window]:Text[:Data] "<String>"Display[:Window]:Text[:Data]
58
Display[:Window][:State] on | 1 | off | 0Display[:Window][:State]
58
IEEE-488 Subsystem
59
Cls
59
ESE <Enable Value>*Ese
59
Standard Event Status Enable Register
59
Esr
59
Idn
59
Opc*Opc
60
Opt
60
Psc 0|1*Psc
60
Rst
60
RCL <State>*Sav <State
60
SRE <Enable Value>*Sre
61
Stb
61
Trg
61
Tst
61
Wai
61
Measure Subsystem
62
Measure:current[:DC]
62
Measure[:Voltage][:DC]
62
Output Subsystem
63
Output[:State] on | 1 | off | 0Output[:State]
63
Output:protection:clear
63
Output:pon:state
63
Rst|Rcl0|Rcl1|Rcl2|Rcl3|Rcl4|Rcl5|Rcl6|Rcl7|Rcl8|Rcl9|Output:pon:state
63
Status Subsystem
64
Status:operation:[Event]
64
Status:operation:condition
64
Status:operation:enable <Value
64
Status:preset
64
Status:questionable:condition
64
Status:questionable:enable <Enable Value>Status:questionable:enable
65
Status:questionable[:Event]
65
System Subsystem
66
System:error[:Next]
66
System:local
66
System:remote
66
System:rwlock
67
System:security:immediate
67
System:version
67
Triggering Commands
68
Abort
68
Initiate[:Immediate]
68
Initiate:continuous on | 1 | off | 0Initiate:continuous
68
Trg
68
Trigger[:Sequence]:Delay <Seconds> Minimum | Maximumtrigger[:Sequence]:Delay? [Minimum | Maximum]
68
Trigger[:Sequence]:Source BUS | Immediatetrigger[:Sequence]:Source
68
Voltage Subsystem
69
[Source:]Voltage[:Level][:Immediate][:Amplitude] <Voltage>|Minimum|Maximum|Default [Source:]Voltage[:Level][:Immediate][:Amplitude]? [Minimum | Maximum]
69
[Source:]Voltage[:Level][:Immediate]:Step[:Increment] <Numeric Value>|Default [Source:]Voltage[:Level][:Immediate]:Step[:Increment]? [Default]
69
[Source:]Voltage[:Level]:Triggered[:Amplitude] <Voltage>|Min|Max[Source:]Voltage [:Level]:Triggered[:Amplitude]? [MIN|MAX]
69
[Source:]Voltage:protection:clear
69
[Source:]Voltage:protection:state On|1|Off|0[Source:]Voltage:protection:state
69
[Source:]Voltage:protection:tripped
69
[Source:]Voltage:protection[:Level] <Voltage>|Minimum | Maximum [Source:]Voltage:protection[:Level]? [Minimum|Maximum]
69
[Source:]Voltage:sense[:Source] Internal | External
70
3 Service and Support
72
Service and Repair
73
Types of Service Available
73
Obtaining Repair Service (Worldwide)
73
Repackaging for Shipment
73
Cleaning and Handling
73
Cleaning
73
Electrostatic Discharge (ESD) Precautions
74
Troubleshooting
74
Self-Test Procedures
74
To Replace the Power-Line Fuse
75
User Replaceable Parts
75
Performance Verification
76
Recommended Test Equipment
76
Test Considerations
76
Measurement Techniques
77
Voltmeter
77
Current-Monitoring Resistor
77
Electronic Load
77
Setup for most Tests
78
Constant Voltage (CV) Verification
79
Voltage Programming and Readback Accuracy
79
CV Load and Line Regulation
80
CV Load Regulation
80
CV Line Regulation
81
Transient Response Verification
81
Output Noise Verification
84
Constant Current (CC) Verification
86
Current Programming and Readback Accuracy
86
CC Load Regulation
87
CC Line Regulation
88
Test Record Forms
89
Keysight E36102A
89
Keysight E36103A
90
Keysight E36104A
91
Keysight E36105A
92
Keysight E36106A
93
Calibration Adjustment Procedures
95
Closed-Case Electronic Calibration
95
Calibration Interval
95
Calibration Adjustment Process
95
Calibration Security
95
Calibration Count
96
Calibration Message
97
Saving Calibration Data
97
Calibration Auto Save
97
Calibration Procedure
97
Enter the Calibration State
97
Calibrate Voltage
98
Calibrate Current
98
Calibrate Small Current
98
Save the Calibration Data
99
Specifications and Typical Characteristics
100
Performance Specifications
100
Typical Characteristics
101
Supplemental Characteristics
102
Advertisement
Advertisement
Related Products
Keysight Technologies E36100B Series
Keysight Technologies E36102B
Keysight Technologies E36103B
Keysight Technologies E36104B
Keysight Technologies E36105B
Keysight Technologies E36106B
Keysight Technologies E36150 Series
Keysight Technologies E36154A
Keysight Technologies E36155A
Keysight Technologies E3643A
Keysight Technologies Categories
Measuring Instruments
Test Equipment
Control Unit
Portable Generator
Power Supply
More Keysight Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL