Sign In
Upload
Manuals
Brands
Kaelus Manuals
Test Equipment
iPA2600A
Kaelus iPA2600A PIM Test Analyzer Manuals
Manuals and User Guides for Kaelus iPA2600A PIM Test Analyzer. We have
2
Kaelus iPA2600A PIM Test Analyzer manuals available for free PDF download: Operating Manual, Manual
Kaelus iPA2600A Operating Manual (96 pages)
iPA A-SERIES The Battery Operated Intermodulation Test System
Brand:
Kaelus
| Category:
Test Equipment
| Size: 7.63 MB
Table of Contents
Table of Contents
5
1 Operating Instructions
11
Introduction
11
Functional Description
11
Features
11
Specifications
12
Construction and Layout
13
Figure 1 Ipa and Tablet PC Front View
13
Figure 2 Monitor Port, External Wi-Fi Port and DC Input Socket
15
Figure 3 SD Card, USB and Mini USB Port
16
Minimum Browser Requirements
17
Equipment Operation - Fixed Frequency Mode
17
Starting the Equipment - Ipa
17
Figure 4 Ipa Start up Window
17
The Main Application Window - Ipa
18
Figure 5 Ipa Fixed Frequency Window (Default Measurement Mode)
18
Screen Zoom Functions (Local Control)
19
Figure 6 Zoom Select Region Local Control
19
Figure 7 Zoom Adjustment Horizontal (Local Control)
20
Figure 8 Zoom Adjustment Vertical (Local Control)
21
Figure 9 Pan Window Adjustment (Local Control)
21
Starting the Equipment - Samsung Galaxy Tab
22
Figure 10 Settings Window Table PC
22
Starting the Equipment - Ipad
23
Figure 11 Ipad Start up Window
23
Figure 12 Ipad Initial Front Panel Display (Fixed Frequency Window)
24
Controlling the Ipa Via Wi-Fi
25
Return IPA to Local Mode
26
Turning RF "On" Via the Remote Browser
26
Fixed Frequency Window
27
Figure 13 Browser.ipa Fixed Frequency Window (RF "On")
27
Recalling State Files
30
Figure 14 Test State Settings Window
30
Shutting down the Instrument
31
Equipment Operation - Settings Mode
31
Changing Instrument Settings
31
Modifying RF "On" Timer Setting
31
Figure 15 Shutdown Window
31
Figure 16 Ipa RF "On" Timer Window
32
Modifying Test Tone Frequency and Power Level
33
Figure 17 TX Tones Power and Frequency Settings Menu (Tablet PC)
33
Modify the IM Product
34
Figure 18 Calculated IM Products
34
Modifying the IM Pass/Fail Threshold
35
Figure 19 Ipa IM Treshold Level Window
35
Battery Charge Level Monitor, Monitor Port Gain and System Temperatures
36
Figure 20 Ipa Battery Window
36
Instrument Settings Menus
37
Figure 21 Ipa Settings about Window
37
Figure 22 Ipa Settings Capabilities Window
38
Figure 23 Ipa Settings Region Window
39
Figure 24 Ipa Network Settings Window
40
Figure 25 Ipad Settings Menu Selection
41
Figure 26 Ipad Selecting Your Wi-Fi Hotspot (Serial Number)
42
Figure 27 Ipad Network Information Windows
43
Instrument Settings - Instrument States
44
Figure 28 Instrument State Window
44
Instrument Settings Miscellaneous Window (Remote Control)
46
Figure 29 Miscellaneous Settings Window
46
Instrument Settings Miscellaneous Window (Local Control)
47
Figure 30 Miscellaneous Settings Window (Local Control)
47
Editing Measurement Tag Points
48
Figure 31 Add Measurement Tag Label
49
Equipment Operation - Measurement Modes
50
Fixed Tone
50
Figure 32 Mode Selection Menu
50
Figure 33 Tablet PC PIM Vs Time Window Mode (RF "On")
51
Frequency Sweep
52
Figure 34 Swept Measurement Window
52
Figure 35 Frequency Step Selection Window
53
Spectrum Monitor Mode
54
Figure 36 IM Order Selection Window
54
Figure 37 Spectrum Analyzer Measurement Window (Local Display)
55
Range to Fault Mode (Optional Module)
56
Figure 38 Range to Fault (RTF) Measurement Window
56
Eco Mode
57
Figure 39 Immediate Switch to Eco Mode (Via Mode Menu)
57
Figure 40 Eco Mode Display
58
Eco Mode and Dimmer Timer Setting
59
Figure 41 Eco Mode and Screen Dimming Timer Menu
59
Iva Mode/Ipa Mode
60
Generating Reports
60
Overview
60
Figure 42 Iva Measurement Modes
60
Customizing Your Report Contractor Name, Details and Logo
61
Report File Formats
61
Setting up the Site Test Report
62
Figure 43 Report Window
62
Taking an RF Measurement and Adding Measurement Tags
63
Figure 44 Add Measurement Tag Input Screen
63
Figure 45 Removing Measurement Tags
64
Figure 46 Default Measurement Window
65
Viewing a Test Report
66
Figure 47 Report Browsing Window
66
Figure 48 Report Window Items Expanded
67
Saving Reports
68
Figure 49 Report Save Window
68
Saving Ipa Screen Shots for Inclusion in Reports
69
Saving Ipa Screen Shots (Not Included Directly in Reports)
69
Figure 50 Screen Shots Local Display to be Added to Reports
69
Figure 51 Local Screenshot Touch Point (Not for Inclusion in Report)
70
Moving Items Around in a Report
71
Uploading and Downloading Reports, Files and Photos
71
Figure 52 Upload and Download Menu
71
Figure 53 Upload File Dialogue
72
Uploading Files to the Ipa
72
Figure 54 Uploading Files from the Open Report Menu
73
Downloading Files
74
Figure 55 Uploading Photos into Reports
74
How Language Functions and Settings Effect Report Generation
74
Uploading Photos into Reports
74
PDF Report Layout
75
Figure 56 PDF Report Layout
75
2 Connection Options
76
Ipa as an Access Point
76
Figure 57 Wi-Fi Connection Options (Ipa Hotspot)
76
Tablet or Smartphone as an Access Point
77
Figure 58 Wi-Fi Connection Options (Smartphone Hotspot)
77
Connect to Iva Via Additional Bluetooth Interface
78
Figure 59 Ipa to Iva Connection Via Bluetooth
78
Figure 60 Wi-Fi Connection Options (External Access Point)
79
Ipa Client Connection Mode
80
Overview
80
Enabling Wifi Client Mode
81
Connecting the Ipa to the External Wireless Access Point
81
Figure 61 Select Wi-Fi Enabled (Client Mode)
81
Figure 62 Wi-Fi Settings, Network Selection and Password Menu
81
Establishing the IP Address of Your Ipa
82
Connect Your Other Devices
82
Figure 63 IP Address Allocated by the Access Point
82
External Wireless Access Point Examples
83
Enable WEP/WPA Security on an External Wireless Access Point
83
Enable a DHCP Server Function
83
Figure 64 Select WEP Security on External Access Point
83
Figure 65 Enabling DHCP on External Access Point
83
Figure 66 Manual IP Assignment External Wireless Acess Point Example
84
Outside Connection Via Wireless Router
85
Figure 67 Typical NAT Configuration from an Intranet
85
Figure 68 Internet Connection Via VPN
85
Mobile Phone as an External Hotspot
86
Figure 69 Phone Connection Settings
86
Figure 71 Select Hotspot Configuration Menu
87
Figure 73 Configure Name. Password and Security
88
3 General Detail
89
Getting the Best from the Test Equipment
89
Safety Features
90
Accessories Kits
90
Handling and Transport
90
Cleaning the Equipment
90
External Charger
91
RTF (Range to Fault) Unit
91
Figure 74 External Battery Charger (Optional)
91
Figure 75 RTF Range to Fault Unit (Optional)
91
Iva (Cable and Antennae Analyser)
92
USB Bluetooth Interface
92
Figure 76 Iva Cable and Antennae Analyser (Optional)
92
Figure 77 Ipa Bluetooth Dongle for Iva (R92-0589)
92
Troubleshooting Guide
93
CE Declaration of Conformity
95
End of Life Statement
96
Contacts
96
Advertisement
Kaelus iPA2600A Manual (19 pages)
Brand:
Kaelus
| Category:
Measuring Instruments
| Size: 4.1 MB
Table of Contents
Table of Contents
2
General
3
Purpose
3
Scope
3
Audience
3
RF Safety
3
Equipment Overview
4
1-Port PIM Finder Solution
4
Accessory Kit: Iak-0060A
4
PIM Mitigation and Tools
5
Passive Intermodulation Analyser and Range to Fault Module
5
Uplink Filters
5
Ipa Measurement Modes
6
Process Flow
7
Before Going to the Site
7
PIM Finding Process Overview
7
Step by Step Instruction
8
PIM Hygiene
8
Instrument Preparation
9
Decide on the Frequency Setting of the Instruments
9
Prepare the Test Configuration and Reporting
10
Prepare the Instrument
10
Interference Check
12
Perform a Swept PIM Test of the Site
12
Perform Range to Fault (RTF) Measurements
13
PIM Finder Mode
17
Verify the PIM Level
19
Document Your Findings
19
Advertisement
Related Products
Kaelus iPA2100A
Kaelus iPA0703A
Kaelus iPA0790A
Kaelus iPA0850A
Kaelus iPA0900A
Kaelus iPA0901A
Kaelus iPA1800A
Kaelus iPA0707A
Kaelus iPA1900A
Kaelus iPA1921A
Kaelus Categories
Measuring Instruments
Test Equipment
Racks & Stands
Control Unit
Battery Charger
More Kaelus Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL