Sign In
Upload
Manuals
Brands
Jade Bird Manuals
Control Panel
JBE-P2L1
Jade Bird JBE-P2L1 Analog Control Panel Manuals
Manuals and User Guides for Jade Bird JBE-P2L1 Analog Control Panel. We have
2
Jade Bird JBE-P2L1 Analog Control Panel manuals available for free PDF download: Installation & Operation Manual
Jade Bird JBE-P2L1 Installation & Operation Manual (56 pages)
Draco Fire Control Panel
Brand:
Jade Bird
| Category:
Control Panel
| Size: 2.67 MB
Table of Contents
Table of Contents
3
Introduction
6
General Product Description
6
Overview
6
54 Optional Features
6
Additional Ancillary Functions
8
Certification
8
Technical Specifications
9
General Data
9
Power Supply
9
Batteries
9
Product Range and Compatibility
10
Panel's Optional Modules
10
Second Loop Card (JBE-P2L1-EXLP)
10
Printer (JBE-PRT)
10
External Battery Box for 17 Ah Batteries (JBE-BAT)
10
Installation
11
Pre-Installation Checks
11
Selection of the Location of Installation
11
Mechanical Dimensions and Wall Area
11
Planning Wire Topology to Meet en 54-2 Requirements on Integrity of Transmission Paths
12
Physical Mounting Instructions
12
Panel Assembly
12
Assembly of JBE-P2L1-EXLP (Draco 2Nd Loop Card)
12
Assembly of JBE-PRT (Draco Printer)
13
Assembly of JBE-BAT (Draco Battery Box)
13
Mounting to the Wall
14
Electric Wire Connections
15
Fitting the Batteries
17
Commissioning Using the Wizard
19
Initiating the Wizard
19
Auto-Registration of Loop Devices
19
Assign Devices to Zones
19
Set Address Descriptions
20
Assign Outputs to Activation Groups
20
Change Passwords
20
Operation Instructions
21
General Indications
21
Visual Indications
21
LED Indicators
21
LCD User Interface
23
Control Keys
24
Acoustic Warnings
25
Description of User Access Levels and Default Login Passwords
26
Operations Available to All Users (Access Level 1 and Above)
26
Silencing the Buzzer
26
View Menu
27
View Event Log
27
View Faults
28
View Disablements
29
View Zones under Test
29
View Zone Status
29
View Device Status
29
View Address Descriptions
29
Product Serial Numbers
29
View System Composition and Date of Last Configuration
30
Maintenance Company Details
30
Operations Available to Users with Access Level 2 and above
30
Reset
31
Activate Delays
31
Operate Menu
31
Test Zone
31
Test Output Group
31
Keyboard Test
32
Indicators Test
32
Disable Zone
32
Disable Output Group
32
Disable Device
32
Set Time and Date
32
Report Menu
33
Print Event Log
33
Field Device Type Status
33
View Serial Numbers and Firmware Versions
34
Loop State Signal Report
34
Field Device Raw Data Report
34
Field Device State Signal Value
34
View Advanced Programming
34
View Addresses Linked to a Zone
34
View Addresses Used in a Loop
34
Operations Available Only to Users with Access Level
35
Adjust Menu
35
Registro O Borrado Manual de Dispositivos de Lazo
35
Set Address Description
35
Assign Devices to Zones
35
Retardos y Causa-Efecto de SND/FR por Zona
36
Set Loop Class (a or B)
36
Assign Device to Activation Group
38
Enter Maintenance Company Details
38
View Analog Value Curve of a Detector
38
Configure Day/Night Mode
38
Setup Printer
40
Install Menu
40
Wizard
40
Auto-Registration
40
Set Password
40
Set Language
40
Set Special Operation Mode
41
Enter Advanced Programming
41
Clear
45
System Configuration
45
Online Configuration Tool
45
USB Configuracion / Upgrade
46
Save Event Log to USB Data
46
Save All Configuration to USB
46
Load Configuration from USB
46
USB Firmware Update
46
Operation in Case of Alarm
47
Panel's Audible Alarm Indication
47
Panel's Visual Alarm Indications
47
The Alarm Screen
47
Output Activation - Delay Override
48
Resetting the Fire Panel
48
Operation in Case of Fault
49
Indication of Common Faults
49
Indication of Faults Affecting Snd or Fr Outputs
50
Indication of Earth Faults
50
Indication of System Faults
50
Maintenance
51
Planned Maintenance & Periodic Inspections
51
Battery Maintenance
51
Cleaning
51
Menu Tree Structure
52
View Menu (User Access Level 1)
52
Operate & Report Menus (User Access Level 2)
52
Adjust & Install Menus (User Access Level 3)
53
List of Figures
54
Advertisement
Jade Bird JBE-P2L1 Installation & Operation Manual (53 pages)
Brand:
Jade Bird
| Category:
Control Panel
| Size: 3.53 MB
Table of Contents
Table of Contents
3
Introduction
6
General Product Description
6
Overview
6
54 Optional Features
6
Additional Ancillary Functions
8
Regulatory Information
8
Technical Specifications
9
General Data
9
Power Supply
9
Batteries
9
Product Range and Compatibility
10
Panel's Optional Modules
11
Second Loop Card (JBE-P2L1-EXLP)
11
Printer (JBE-PRT)
11
External Battery Box for 17 Ah Batteries (JBE-BAT)
11
Installation
12
Pre-Installation Checks
12
Selection of the Location of Installation
12
Mechanical Dimensions and Wall Area
12
Planning Wire Topology to Meet en 54-2 Requirements on Integrity of Transmission Paths
13
Physical Mounting Instructions
14
Panel Assembly
14
Mounting to the Wall
15
Electric Wire Connections
17
Fitting the Batteries
19
Commissioning Using the Wizard
21
Initiating the Wizard
21
Auto-Registration of Loop Devices
21
Assign Devices to Zones
21
Set Address Descriptions
21
Assign Outputs to Activation Groups
21
Change Passwords
21
Operation Instructions
22
General Indications
22
Visual Indications
22
LED Indicators
22
LCD User Interface
24
Control Keys
25
Acoustic Warnings
27
Description of User Access Levels and Default Login Passwords
27
Operations Available to All Users (Access Level 1 and Above)
28
Silencing the Buzzer
28
View Menu
28
View Event Log
28
View Faults
29
View Disablements
30
View Zones under Test
30
View Addresses Linked to a Zone
30
View Zone Status
30
View Device Status
30
View Addresses Used in a Loop
31
View Address Descriptions
31
View System Composition and Date of Last Configuration
31
Operations Available to Users with Access Level 2 and above
32
Reset
32
Activate Delays
32
Operate" Menu Tree
32
Test Zone
32
Test Output Group
33
Keyboard Test
33
Indicators Test
33
Disable Zone
33
Disable Output Group
33
Disable Device
33
Set Time
34
View Serial Numbers and Firmware Versions
34
Report" Menu Tree
34
Print Event Log
34
Save Configuration or Event Log to USB
35
Field Device Type Status
35
Product Serial Numbers
35
Loop State Signal Report
35
Field Device Raw Data Report
35
Field Device State Signal Value
35
View Advanced Programming
35
Operations Available Only to Users with Access Level 3
36
Adjust" Menu Tree
36
Individual Device Registration
36
Set Address Description
36
Assign Devices to Zones
36
Delays and Linkage of SND/FB by Zone
37
Set Loop Class (a or B)
37
Assign Device to Activation Group
38
Enter Maintenance Company Details
38
View Analog Value Curve of a Detector
38
Configure Day/Night Mode
38
Set Printer
40
Install" Menu Tree
40
Wizard
40
Auto-Registration
40
Set Password
40
Set Language
40
Set Special Operation Mode
41
Enter Advanced Programming
41
Clear
44
USB Firmware Update
45
System Configuration
45
Load Configuration from USB
45
Operation in Case of Alarm
46
Anels Audible Alarm Indication
46
Anels Visual Alarm Indications
46
The General Fire Alarm Indicator
46
The Alarm Screen
46
Output Activation - Delay Override
47
Resetting the Fire Panel
47
Maintenance
48
Planned Maintenance
48
Periodic Inspections & Maintenance
48
Battery Maintenance
48
Cleaning
48
Corrective Maintenance: Operation in Case of Fault
48
Indication of Common Faults
49
Indication of Faults Affecting SND or FB Outputs
49
Indication of Earth Faults
49
Indication of System Faults
49
Menu Tree Structure
50
View Menu (User Access Level 1)
50
Operate & Report Menus (User Access Level 2)
50
Adjust & Install Menus (User Access Level 3)
51
List of Tables
52
List of Figures
53
Advertisement
Related Products
Jade Bird Draco Fire
Jade Bird Categories
Control Panel
Fire Alarms
Safety Equipment
More Jade Bird Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL