Sign In
Upload
Manuals
Brands
ITRON Manuals
Measuring Instruments
CENTRON C1SR
ITRON CENTRON C1SR Electricity Meter Manuals
Manuals and User Guides for ITRON CENTRON C1SR Electricity Meter. We have
1
ITRON CENTRON C1SR Electricity Meter manual available for free PDF download: Technical Reference Manual
ITRON CENTRON C1SR Technical Reference Manual (107 pages)
Brand:
ITRON
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Test Report
1
Table of Contents
6
Chapter 1 General Information
14
About this Manual
14
General Description
15
Physical Description
16
Meter Base
16
Personality Modules
17
Product Availability
17
Battery
17
Covers
18
Outputs
18
Display Functions
18
Specifications
18
Electrical
18
Operating Environment
18
Characteristic Data
19
Burden Data
19
Technical Data
20
Dimensions
20
C1SD/C1ST/C1SL Dimensions
21
Shipping Weights
21
Chapter 2 Installation
22
Inspection
22
Battery
22
Storage
22
Unpacking
23
Selecting a Site
23
Installing the Meter into Service
23
Programming the C1SD,T,L Meter
24
Retrofitting with Personality Modules
24
Removing the Board-To-Board Connector
25
New Module Snap-In
26
Board-To-Board Connector, Bottom
27
Chapter 3 Operation: Base Metrology
30
CENTRON 1S, 2S CL200, and 3S
30
Power Measurement Principle in 2S
31
Centron 2S Cl320, 4S, 12/25S
32
Hall Cells and Adcs
33
Chapter 4 Operation: C1S Version
34
Physical Description
34
Registers
35
Kilowatt Hours
35
Resetting Values
35
ZRO-C2A Resetter Connected to the CENTRON
36
LCD Display Function
37
Pre-June 2003 Lcds
37
LCD Display Without Segment Check
38
Post-June 2003 Lcds
39
Non-Detented Register
39
Detented Register
40
Net Register
40
Segment Check
40
Factory Programming Options
41
Chapter 5 Operation: C1SD, C1ST, and C1SL Versions
42
Features
42
Controls and Indicators
43
Modes of Operations
44
Normal Mode
44
Alternate Mode
44
Test Mode
44
Test Mode
45
Low Power Mode
46
Displays
46
Programmable Functions
47
Register Display Options
48
Self Reading
49
Last Season Registers
50
Operating Parameters
50
Informational Data
51
Test Mode Data
53
Programming the Meter with a 200 Series Program
54
Program File Export Type
55
Demand Reset
56
Time-Of-Use
56
Calendar Schedule
56
TOU Schedules
56
Current Season Register
57
Daily Schedules
57
Daylight Savings Time
57
Rate Schedules
57
Registers
57
Seasonal Schedules
57
Last Season Registers
58
Load Profile Specifications
58
Bit Resolution
58
Capacity
58
Channel Configurations
59
Interval Lengths
59
Power Outage
59
Data Storage
60
Recording Duration
60
Optional Features
61
Electronic Detent
61
Expansion Port
61
Security Codes
61
Calculations
62
Demand
62
Energy
62
Demand Calculations
63
Power Procedures
64
Applying Power
64
Battery Life (Load Profile & TOU)
64
Example 1
65
Example 2
66
Example 3
67
Low Battery Error
67
Effectivity Date
68
Three Button Reset
68
Option Boards
68
CENTRON R300CD Operation
68
Programming the R300CD Meter
69
Errors
70
Chapter 6 Operation: C1SR Version
72
Physical Description
73
C1Sr
73
Registers
74
Display
74
Electronic Detent
75
Resetting Values
75
Transmission Scheme
75
FCC Regulations
76
Tamper Detection
76
Testing the CENTRON C1SR Tamper Counter
77
Retrofitting the C1SR Personality Module
78
C1SR FCC Label Location
79
Chapter 7 Operation: C1SC Version
82
C1Sc
82
Physical Description
83
Transmission Scheme
83
Display Functions
84
FCC Regulations
84
Resetting Values
85
Programming the C1SC/CN1SC
85
C1SC/CN1SC Programming Port Location
86
Chapter 8 Testing, Troubleshooting, and Maintenance
88
Testing Support Features
88
Infrared Test LED
88
Pulse Detector
88
Annunciators
89
TOU Rate Annunciators
89
Watthour Annunciators
89
Test Mode Annunciator
90
Testing with the Infrared Test LED
90
Testing Using the Disk Emulation Annunciator
91
Recommended Energy Testing Procedures
91
AEP Test Codes
91
Field Testing
91
Required Hardware
91
Troubleshooting
92
Error Codes (R300)
92
Fatal Error
92
Non-Fatal Error
92
Error Codes (Demand, TOU, and Load Profile)
92
Non-Fatal Error Codes
93
Fatal Error Codes
94
Inspecting and Troubleshooting-General
95
Blank Display
95
Time and Date Wrong (TOU or Load Profile Only)
95
No Accumulation of Kwh or Kw
95
Software Cannot Communicate with Module
96
Reed Switch Does Not Activate the Alternate Mode
96
Reset Mechanism Does Not Initiate Demand Reset
96
Demand Reset Cannot be Initiated through PC or Handheld
96
Test Mode Switch Does Not Place Module in Test Mode
97
Inspecting and Troubleshooting-C1S LCD and C1SR
97
Blank Display
97
Chapter 9 Specifications and Drawings
98
Specifications
98
Drawings
98
Form 2S Wiring Diagram
99
Form 4S Wiring Diagram
100
Form 25S Wiring Diagram
101
Advertisement
Advertisement
Related Products
ITRON CENTRON C1S
ITRON CENTRON C1ST
ITRON CENTRON C1SL
ITRON CENTRON C1SC
ITRON CENTRON C1SD
Itron Centron
ITRON CCU 100
ITRON SHARPFLOW CWB7
ITRON CENTRON CP1SR
ITRON CENTRON CP1SL
ITRON Categories
Measuring Instruments
Control Unit
Controller
Data Loggers
Industrial Equipment
More ITRON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL