Sign In
Upload
Manuals
Brands
Industrial Data Systems Manuals
Measuring Instruments
IDS 430
Industrial Data Systems IDS 430 Manuals
Manuals and User Guides for Industrial Data Systems IDS 430. We have
1
Industrial Data Systems IDS 430 manual available for free PDF download: Installation/Calibration/Operation
Industrial Data Systems IDS 430 Installation/Calibration/Operation (132 pages)
Weight Indicator
Brand:
Industrial Data Systems
| Category:
Measuring Instruments
| Size: 2.01 MB
Table of Contents
Section 1
3
Table of Contents
3
Introduction
6
What's in each Section
7
Warranty Information
8
General Description
9
The IDS 430 Display and Keyboard Diagram
9
The IDS 430 Display
10
The IDS 430 Keyboard
10
Installation and Setup
11
Unpacking the IDS 433/430
11
Installation Guide /Safety Instructions
11
Setup Guide
13
NTEP Labeling Instructions
14
Operation of Function Keys
15
Using the IDS 430/433
15
Keyboard Layout
15
Memory Registers Entry
16
Execute a Scale Basic Function
16
Display Time and Date
16
Built in Application Programs
17
Set Operation Parameters
27
Operation Parameter Reference Tables
27
Parameter 3. Display Update Rate (0)
31
Scale Parameters
31
Parameter 2. Digital Filter
31
Parameter 4. Motion Detection Delay
32
Parameter 5. Motion Detection Band
32
Parameter 7. Zero Tracking Delay
32
Parameter 8. Zero Tracking Band
32
Parameter 12. Count-By
33
Parameter 13. Alternate Units Type (2[Kg])
33
Parameter 9. Push Button Zero Percent
33
Parameter 11. Decimal Point Position (0[No Decimal Point])
33
Parameter 10. Primary Units Type (1[Lb])
33
Parameter 14. Alternate Decimal Point
34
Parameter 15. Alternate Count-By
34
Parameter 17. Full Scale Graduations (10,000)
34
Parameter 18. Overload Graduations
34
Parameter 21. Deadload Factor (Automatically Set)
35
Parameter 22. Weight Conversion Factor (Automatically Set)
35
Parameter 23. Serial Port 1 Mode (4[8 Data Bits, no Parity])
35
Parameter 24. Serial Port 1 Baud Rate (1[9600 Baud])
36
Parameter 25. Serial Port 2 Mode (4[8 Data Bits, no Parity])
36
Parameter 26. Serial Port 2 Baud Rate (1[9600 Baud])
36
Parameter 27. TX2 Control / Station ID (255[Single Station])
37
Printer Parameters
38
Parameters 32, 33, 34, 84, 85, 86, 87, 88 and 90 Print Labels
38
Parameters 35, 36, 37 and 38. Print Codes
39
Display Intensity, Watch Dog Timer
40
Parameter 40 Display Intensity
40
Parameter 42. Enable Watch Dog Timer (0)
40
Parameter 43-50. Fixed Registers
40
Parameters 51-58 Keyboard Event Functions
40
Parameter Functions
41
Function 59 Display Calibration Audit Number
42
Function 60 Calibrate Scale - Deadload First
43
Function 61 Calibrate Scale - Span First
43
Function 62 Calibrate Deadload Only
44
Function 63 Adjust Gain Calibration
44
Function 64 Configure Passwords
45
Function 65 Configure Print Formats
46
Function 67 Display Operation Parameters
51
Function 68 Print Operation Parameters
51
Function 69 Diagnostic Tests
52
Function 70. Initialize Operation Parameters to Factory Default
52
Function 71 Configure Event Monitor
53
Function 72 Scale Basic Function Editor
53
Function 74 Configure Timers
55
Function 78 Initialize ID Memory
55
Diagnostic Tests
57
Table of Diagnostic Tests
57
Diagnostic Test 1: Serial Com Port 1 - Display Input Data
57
Diagnostic Test 6: Serial Com Port 2 - Transmit Data
58
Diagnostic Test 5: Serial Com Port 2 - Display Errors
58
Diagnostic Test 4: Serial Com Port 2 - Display Input Data
58
Diagnostic Test 3: Serial Com Port 1 - Transmit Data
58
Diagnostic Test 2: Serial Com Port 1 - Display Errors
58
Diagnostic Test 10: Lamp Test
59
Diagnostic Test 11: Print EAROM Configuration Table
60
Troubleshooting
61
Error Messages
62
Hardware Installation and Wiring
63
Load Cell Connector - TB1
63
Power Source AC/DC
63
I/O Port Connector - TB3
63
P.C. Board Diagram - Connectors, Jumpers, and Switches
64
Analog Output Offset
65
Analog Output Span
65
Analog Output Register
65
Specifications
67
Section 2
69
Introduction
72
What's in each Section
73
Warranty Information
74
General Description
75
IDS440 Display and Keyboard Diagram
75
Control Keys
76
Function Keys
76
Numeric Keypad
76
The IDS440 Display
76
The IDS440 Keyboard
76
Connect IDS440 to Load Cell
77
Connect IDS440 to the Printer (Optional)
77
Installation and Setup
77
Installation Guide
77
Item Check List
77
Unpacking the IDS440
77
Apply AC Power to the IDS440
78
Connect IDS440 to Host Device (Optional)
78
Calibrate the Weight Indicator
79
Initialize to Factory Defaults
79
Setup & "Quick" Calibration Guide
79
Setup Guide
79
Keyboard Layout
80
Operation of Function Keys
80
Using the IDS440
80
Zero
80
Display Time & Date (Optional)
81
Execute a Scale Basic Function
81
F1 and F2
81
Gross/Net
81
Memory Register Entry
81
Print
81
Tare
81
Built in Application Programs
83
Fill to Setpoint
84
Checkweigh: Under/Between/Over
85
Weigh-In / Weigh-Out
86
Axle Weigh - Short Scale
88
Axle Weigh - Long Scale, Unattended
89
ID, Tare, and Total
90
Peak Hold Function
91
Access Operation Parameters and Parameter Functions
92
Operation Parameters Reference Tables
92
Set Operation Parameters
92
Scale Parameters
93
(3 MV/V)
96
Parameter 1. Load Cell MV/V
96
Parameter 2. Digital Filter (9)
96
Parameter 3. Display Update Rate (1)
96
Parameter 4. Motion Detection Delay (6)
97
Parameter 5. Motion Detection Band (6)
97
Parameter 6. Display Blanking During Motion (no Blanking)
97
Parameter 7. Zero Tracking Delay (0)
97
Parameter 8. Zero Tracking Band (12)
97
Parameter 9. Push Button Zero Percent (100)
97
Parameter 10. Primary Units Type (1 [Lb])
98
Parameter 11. Decimal Point Position (0 [No Decimal Point])
98
Parameter 12. Count-By (1)
98
Parameter 13. Alternate Units Type (2 [Kg])
98
Parameter 14. Alternate Decimal Point (1)
98
Parameter 15. Alternate Count-By (5)
99
Parameter 16. Alt Units Conversion Factor (45,360)
99
Parameter 17. Full Scale Graduations (10,000)
99
Parameter 18. Overload Graduations (10,200)
99
Parameter 19. Deadload Offset
99
Parameter 20. Disable Power-On Zero (1 [Disabled])
99
Parameter 21. Deadload Factor
100
Parameter 22. Weight Conversion Factor
100
Parameter 23 Serial Port 1 Mode (4 [8 Data Bits, no Parity])
100
Serial I/O Ports
100
Parameter 24 Serial Port 1 Baud Rate (1 [9600 Baud])
101
Parameter 25 Serial Port 2 Mode (4 [8 Data Bits, no Parity])
101
Parameter 26 Serial Port 2 Baud Rate (1 [9600 Baud])
101
Parameter 27 TX2 Control / Station ID (255 [Single Station])
101
Parameter 28 TX2 Format (2 Condec Format)
102
Parameter 29 Printer Port Select (2 [Serial Port 1])
103
Parameter 30 Auto Print LF after CR (1 [Yes])
103
Parameter 31 End of Print Character (12 [Form Feed])
103
Parameters 32, 33 34, 84, 85, 86, 87, 88, 89 and 90 Print Labels
103
Printer Parameters
103
Display Intensity, Battery, Watch Dog Timer
104
Parameter 39 Enable TTL Remote Control (1 [Enabled])
104
Parameter 40 Display Intensity (10)
104
Parameter 41 Battery Backup (0 [No])
104
Parameter 42 Enable Watch Dog Timer (0 [No])
104
Parameters 35, 36, 37, and 38: Print Codes
104
Parameters 43-50 Fixed Registers
104
Parameters 51-58 Keyboard Event Functions
105
Access Parameter Functions
106
Parameter Functions
106
Function 59 Display Calibration Audit Number
107
Function 60 Calibrate Scale - Deadload First
107
Function 61 Calibrate Scale - Span First
108
Function 62 Calibrate Deadload Only
108
Function 63 Adjust Gain Calibration
108
Function 64 Configure Passwords
109
Function 65 Configure Print Formats
110
Function 66 Set Time and Date
114
Function 67 Display Operation Parameters
114
Function 68 Print Operation Parameters
114
Function 69 Diagnostic Tests
114
Function 70 Initialize Operation Parameters to Factory Defaults
115
Function 71 Configure Event Monitor
115
Function 72 Scale Basic Function Editor
116
Function 73 Initialize Function Memory
116
Function 74 Configure Timers
116
Parameter 75 Enable Peak Detect
116
Function 78 Initialize ID Memory
117
Function 80 Calibrate - Multi-Point Linearization
117
Parameter 76 Debug Mode for Event Monitors and Scale Basic
117
Parameter 79 Enable Multi-Point Linearization
117
Diagnostic Test 1: Serial Com Port 1 - Display Input Data
119
Diagnostic Test 2: Serial Com Port 1 - Display Errors
119
Diagnostic Tests
119
Table of Diagnostic Tests
119
Diagnostic Test 3: Serial Com Port 1 - Transmit Data
120
Diagnostic Test 4: Serial Com Port 2 - Display Input Data
120
Diagnostic Test 5: Serial Com Port 2 - Display Errors
120
Diagnostic Test 6: Serial Com Port 2 - Transmit Data
120
Diagnostic Test 7: Test Parallel Output
120
Diagnostic Test 10: Lamp Test
121
Diagnostic Test 11: Print the EAROM Configuration Table
121
Diagnostic Test 8: Test A/D
121
Diagnostic Test 9: Perform Internal Memory Test
121
Diagnostic Tests 12 & 13: Loop Back Tests
121
Problems and Probable Causes
122
Troubleshooting
122
Error Messages
123
Hardware and Wiring
124
Load Cell Connector - TB3
124
Serial Port 1 Connector - TB 1
125
Serial Port 2 Connector - TB 2
125
TTL I/O Port Connector - TB 4
126
P.C. Board Diagram - Connectors, Jumpers, and Switches
127
Ids150A/152/160/320
128
Load Cell
128
Sample Cable Drawings
128
DT210/IDS550/IDS710/PC (Continuous Output Port)
129
Hewlett Packard Smart Wand HBCR-8Xxx Series
129
Parallel (Centronix) Printer
130
Remote Switch Inputs
130
IDS440 Specifications
131
Ascii Chart
132
Advertisement
Advertisement
Related Products
Industrial Data Systems IDS 433
Industrial Data Systems IDS 410
Industrial Data Systems IDS 422
Industrial Data Systems IDS 440
Industrial Data Systems Categories
Accessories
Printer
Measuring Instruments
More Industrial Data Systems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL