Sign In
Upload
Manuals
Brands
IAI Manuals
Controller
ACON-CG
IAI ACON-CG Manuals
Manuals and User Guides for IAI ACON-CG. We have
8
IAI ACON-CG manuals available for free PDF download: Instruction Manual, Operation Manual, First Step Manual
IAI ACON-CG Instruction Manual (436 pages)
EtherNet/IP Positioner Type Controller Edition
Brand:
IAI
| Category:
Controller
| Size: 11 MB
Table of Contents
Please Read before Use
3
Construction of Instruction Manual for each Controller Model and this Manual
5
Safety Guide
9
Operation Description
10
Alert Indication
15
Handling Precautions
16
Ethernet/Ip Specifications
20
Acon-C/Cg, Pcon-C/Cg
21
Operation Modes and Functions
21
Monitor LED Indications
26
Connector Pin Layout
27
Setting the Baud Rate
28
Setting the IP Address
29
Setting the Subnet Mask
29
Setting the Default Gateway
29
Position/Simplified Direct Value Mode (Number of Occupied Bytes: 8)
38
Half Direct Value Mode (Number of Occupied Bytes: 16)
43
Full Direct Value Mode (Number of Occupied Bytes: 32)
50
I/O Signal Controls and Function
63
I/O Signal Timings
81
Operation
82
Ethernet/Ip Related Parameters
95
Troubleshooting
101
Model Numbers
107
Ethernet/Ip Interface
108
Monitor LED Indications
108
Connector Pin Layout
109
Setting the Baud Rate
110
Setting the IP Address
111
Setting the Subnet Mask
111
Setting the Default Gateway
111
Position/Simplified Direct Value Mode (Number of Occupied Bytes: 8)
121
Half Direct Value Mode (Number of Occupied Bytes: 16)
126
Full Direct Value Mode (Number of Occupied Bytes: 32)
133
Position/Simplified Direct Value Mode 2 (Number of Occupied Bytes: 8)
148
Signal Type Bit
151
Status B2
152
Signal
152
Unavailable
158
Table of Contents
164
Zone Boundary
166
Control Signal 2
167
Current Position
168
Command Current
168
Current Speed
168
Alarm Code
168
Overload Level Monitor
168
Current Command Value
169
Occupied Area
169
Total Moving Distance
169
Status Signal 2
169
When the Signal Is on
172
B11
173
Status
174
Pzone
174
Position Zone
174
I/O Signal Controls and Function
175
Signal
184
I/O Signal Timings
195
Operation
196
Troubleshooting
216
Operation Modes and Functions
217
Model Numbers
222
Ethernet/Ip Interface
223
Monitor LED Indications
224
Connection Diagram
225
Setting the Baud Rate
226
Setting the IP Address
227
Setting the Subnet Mask
227
Setting the Default Gateway
227
Zone 2: the Signal Is on When the Current Position Is Inside the Specified Zone
259
Zone1
259
I/O Signal Controls and Function
298
I/O Signal Timings
317
Operation
318
Ethernet/Ip Related Parameters
331
Troubleshooting
338
Wiring Example
343
PEND Positioning Complete Signal
359
The Signal Turns on When the Positioning Is Completed
359
Operation Mode: B3 RMDS the Signal Is off When the Current Mode AUTO, or on
359
CEND Loadcell Calibration Completion: on When the Calibration Completion
359
HEND Home Return Completion
359
ON When the Home Return Completion
359
B0 SV Operation Ready: on When the Servo on
359
Connection Example
411
Setting the Controller
411
Setting the PLC (1) [CX-Programmer]
412
Setting the PLC (2) [Network Configurator]
414
Example of Connection Settings with Keyence's Master
425
Setting the PLC
426
Change History
433
Advertisement
IAI ACON-CG Operation Manual (416 pages)
DeviceNet, Positioner Type Controller Edition
Brand:
IAI
| Category:
Controller
| Size: 14 MB
Table of Contents
Table of Contents
1
Please Read before Use
3
Construction of Instruction Manual for each Controller Model and this Manual
5
Acon-Ca/Cb/Cgb
5
Dcon-Ca/Cb/Cgb
5
Pcon-Cb/Cfb/Cgb/Cgfb/Cbp/Cgbp
5
Pcon-Ca/Cfa
5
Pcon-C/Cg
5
Scon-Ca/Cb/Cgb
5
Scon-Cal/Cgal
5
Troubleshooting
8
EDS File
9
Operation Description
11
Safety Guide
11
Alert Indication
17
Handling Precautions
18
Acon-C/Cg, Pcon-C/Cg
21
Operation Modes and Functions
21
Model Numbers
24
Interface Specifications
25
Devicenet Interface
26
Monitor LED Indicators
27
Selecting (Setting) the Operation Mode
28
Setting the Node Address
29
Jog Operation
69
I/O Signal Timings
80
Operation
81
Devicenet Parameters
94
Troubleshooting
99
Operation Modes and Functions
101
Model Numbers
105
Interface Specifications
106
Monitor LED Indicators
108
Selecting (Setting) the Operation Mode
109
Setting the Node Address
110
Target Position
148
Specified Position Number
148
Control Signal
148
Current Position
149
(Simple Alarm Code
151
Status Signal
151
Signal Type Bit
151
Signal
157
Positioning Band
165
Speed
165
Zone Boundary
165
Acceleration
166
Deceleration
166
Push-Motion
166
Current-Limiting Value
166
Load Current
166
Threshold
166
Control Signal
166
Current Position
167
Command Current
167
Current Speed
167
Alarm Code
167
Overload Level Monitor
167
Current Command
168
Occupied Area
168
Total Moving Distance
168
Status B2
168
Status Signal
173
Home Return (HOME)
176
Jog Operation
180
Not Available
189
I/O Signal Timings
193
Operation
194
Devicenet Parameters
207
Troubleshooting
213
Operation Modes and Functions
215
Model Numbers
220
Interface Specifications
221
Devicenet Interface
222
Monitor LED Indicators
223
Setting the Node Address
225
Input Channel Target Position
240
EMGS Emergency Stop: an Emergency Stop Is Being Executed When
257
ALM Alarm: the Signal Turns on When an Alarm Occurs
257
I/O Signal Timings
314
Operation
315
Troubleshooting
333
Setting the Baud Rate
341
Communicating with the Master Station
342
ALML Light Failure Alarm
344
Status Signal
354
The Signal Turns on When an Light Failure Alarm Occurs
354
B11
354
In Normal Condition
354
Position Zone
354
Zone 2: the Signal Is on When the Current Position Is Inside the Specified Zone
355
Zone 1: the Signal Is on When the Current Position Is Inside the Specified Zone
355
PEND Positioning Complete Signal
355
The Signal Turns on When the Positioning Is Completed
355
Operation Mode: B3 RMDS the Signal Is off When the Current Mode AUTO, or on
355
CEND Loadcell Calibration Completion: on When the Calibration Completion
355
HEND Home Return Completion
355
ON When the Home Return Completion
355
B0 SV Operation Ready: on When the Servo on
355
I/O Signal Allocation
363
I/O Signal Controls and Function
368
Brake Release (BKRL)
370
Troubleshooting
404
Change History
411
IAI ACON-CG Instruction Manual (414 pages)
CC-Link, Positioner Type Controller Edition
Brand:
IAI
| Category:
Controller
| Size: 12 MB
Table of Contents
Please Read before Use
3
Construction of Instruction Manual for each Controller Model and this Manual
5
Table of Contents
6
Operation Description
9
Safety Guide
9
Alert Indication
15
Handling Precaution
16
Overview
17
Interface Specifications
19
Acon-C/Cg, Pcon-C/Cg
21
Operation Modes and Functions
21
Model no
24
CC-Link Interface
25
Names of each Section
25
Status LED Indication
25
Operation Mode Selection (Setting)
26
Station No. Setting
26
Communication Speed Setting
27
Communication with the Master Station
28
Each Operation Mode and Corresponding Allocated PLC Addresses
28
Remote I/O Mode (Remote Device Station: No. of Occupied Stations: One Station)
31
Position/Simplified Direct Value Mode
37
One Station)
37
Half Direct Value Mode (Remote Device Station: No. of Occupied Stations: Two Stations)
42
Operation
42
I/O Signal Timing
79
Operation
80
Troubleshooting
98
Operation Modes and Functions
101
CC-Link Interface
106
Names of each Section
106
Station No. Setting
107
Communication Speed Setting
108
I/O Signal Allocation
116
Data
137
Current Speed
140
The Unit Is 0.01Mm. (Example) Read Value : 000003FF = 10.23Mm
140
MM H = 1023 (Decimal)
140
32Bits Data
140
(Example) Read Value: 000003FF = 1023Ma
140
32-Bit Signed Integer
140
Data
140
(Example) Read Value: 000003FF
140
H = 1023 (Decimal)
140
Stores 0 H When no Alarm Is Generated
140
I/O Signal Allocation
145
B15 B14 PWR B13 B12
150
Operation Mode Status: B8 RMDS "OFF" for Currently "AUTO" Mode, "ON" for Currently "MANU
150
Status Signal B7
157
B1 HEND
157
Movement Signal: "ON" with Actuator Movement
157
I/O Signal Timing
192
Operation
193
Troubleshooting
212
Operation Modes and Functions
215
CC-Link Interface
221
Names of each Section
221
Station No. Setting
223
Communication Speed Setting
224
I/O Signal Allocation
276
Operation
314
Troubleshooting
333
Model Numbers
337
Operation Mode Selection
339
Communicating with the Master Station
340
Operation Modes and Corresponding PLC I/O Areas
340
I/O Signal Controls and Function
368
Brake Release (BKRL)
370
I/O Signal Timings
379
Example of Operation
380
Common Items
407
Communication Cable
407
Change History
409
Advertisement
IAI ACON-CG Operation Manual (198 pages)
Controller Positioner Type
Brand:
IAI
| Category:
Controller
| Size: 3 MB
Table of Contents
Table of Contents
9
Safety Guide
15
Overview
23
Introduction
23
How to Read the Model Number
24
System Configuration
25
Internal Drive-Power Cutoff Relay Type (ACON-C)
25
External Drive-Power Cutoff Relay Type (ACON-CG)
26
Procedure from Unpacking to Test Operation and Adjustment
27
Warranty
29
Warranty Period
29
Scope of Warranty
29
Honoring Warranty
29
Limited Liability
29
Conditions of Conformance with Applicable Standards/Regulations, Etc., and Applications
30
Other Items Excluded from Warranty
30
Specifications
31
Basic Specifications
31
Name and Function of each Part of the Controller
32
External Dimensions
34
Installation and Noise Elimination
35
Installation Environment
35
Supplied Voltage
35
Noise Elimination Measures and Grounding
36
Heat Radiation and Installation
37
Wiring
38
Positioner Type (with Internal Drive-Power Cutoff Relay) (ACON-C)
38
External Connection Diagram
38
Wiring the Power Supply/Emergency-Stop Switch
39
Safety Category Type (External Drive-Power Cutoff Relay) (ACON-CG)
46
External Connection Diagram
46
Wiring the Power Supply/Emergency-Stop Switch
47
Connecting the I/O Cables
50
PIO Pattern 0 [Positioning Mode (Standard Type)]
50
PIO Pattern 1 [Teaching Mode (Teaching Type)]
51
PIO Pattern 2 [256-Point Mode (256-Point Type)]
52
PIO Pattern 3 [512-Point Mode (512-Point Type)]
53
PIO Pattern 4 [Solenoid Valve Mode 1 (7-Point Type)]
54
PIO Pattern 5 [Solenoid Valve Mode 2 (3-Point Type)]
55
Connecting the Actuator
57
Wiring the ACON-C/CG and Actuator
57
Connecting the Communication Cable
59
I/O Signal Control and Signal Functions
60
Interface Circuit
60
External Input Specifications
60
External Output Specifications
61
PIO Patterns and Signal Assignments
62
Explanation of Signal Names
63
PIO Pattern = 0 [Positioning Mode (Standard Type)]
63
PIO Pattern = 1 [Teaching Mode (Teaching Type)]
64
PIO Pattern = 2 [256-Point Mode (256-Point Type)]
65
PIO Pattern = 3 [512-Point Mode (512-Point Type)]
66
PIO Pattern = 4 [Solenoid Valve Mode 1 (7-Point Type)]
67
PIO Pattern = 5 [Solenoid Valve Mode 2 (3-Point Type)]
68
Signal Assignment Table for Respective PIO Patterns
69
Details of I/O Signal Functions
70
Details of each Input Signal
70
Operating Mode (RMOD)
70
Start (CSTR)
70
Command Position Number (PC1 to PC256)
71
Pause (*STP)
71
Home Return (HOME)
71
Servo on (SON)
71
Alarm Reset (RES)
72
Brake Release (BKRL)
72
Operation Mode (MODE)
72
Current-Position Write (PWRT)
72
Manual Operation Switching (JISL)
72
Jog (JOG+, JOG-)
73
Direct Position Command (ST0 to ST6) [Solenoid Valve Mode 1 (7-Point Type)]
73
Movement to each Position (ST0 to ST2) [Solenoid Valve Mode 2 (3-Point Type)]
74
Details of each Output Signal
75
Operating Mode Status (RMDS)
75
Completed Position Number (PM1 to PM256)
75
Moving (MOVE)
75
Position Complete (PEND)
75
Home Return Completion (HEND)
76
Zone (ZONE1, ZONE2)
76
Current Operation Mode (MODES)
76
Write Completion (WEND)
76
Movement Complete at each Position (PE0 to PE6) [Solenoid Valve Mode 1 (7-Point Type)]63
77
Position Detection Output at each Position (LS0 to LS2) [Solenoid Valve Mode 2 (3-Point Type)]
77
Ready (SV)
77
Alarm (*ALM)
77
Torque Level Status (TRQS)
77
Emergency Stop (*EMGS)
78
Output Signal Changes in each Mode
78
Data Entry <Basics
79
Description of Position Table
79
Explanation of Modes
84
Positioning Mode Push = 0
84
Push & Hold Mode Push = Other than 0
84
Speed Change During Movement
86
Operation at Different Acceleration and Deceleration Settings
86
Pause
87
Zone Signal Output
87
Home Return
88
Overview of Teaching Mode (Teaching Type)
89
Overview of Solenoid Valve Mode 1 (7-Point Type)
90
Overview of Solenoid Valve Mode 2 (3-Point Type)
92
Power-Saving Modes at Standby Positions
94
Operation <Practical Steps
96
How to Start
96
Timings after Power on
96
Procedure after Initial Startup until Actuator Adjustment
96
Procedure of Normal Operation
98
Position Table and Parameter Settings Required for Operation
101
Startup Adjustment
101
Safety Speed During Manual Feed
101
Speed Override for Movement Commands from the PLC
101
Full-Scale Operation
102
Saving Energy When the Actuator Stands by after Completing the Home Return Operation Effected by the HOME Input Signal
102
Saving Energy When the Actuator Stands by for a Long Time at the Target Position
102
Output Mode of Complete Signal
102
Home Return Operation
103
Method Using the HOME Input Signal (PIO Pattern = 0 to 4)
103
Method Used When no HOME Input Signal Is Available (PIO Pattern = 5)
105
Positioning Mode (Back and Forth Movement between Two Points)
106
Push & Hold Mode
108
Return Action after Push & Hold by Relative Coordinate Specification
110
Speed Change During Movement
111
Operation at Different Acceleration and Deceleration Settings
113
Pause
115
Zone Signal Output
117
Incremental Moves
120
Judgment Method of End Position
122
Notes on Incremental Mode
123
Jogging/Teaching Using PIO
126
Operation of Solenoid Valve Mode 1 (7-Point Type)
128
Operation of Solenoid Valve Mode 2 (3-Point Type)
132
Parameters
136
Parameter Table
136
Detail Explanation of Parameters
138
Parameters Relating to the Actuator Stroke Range
138
Soft Limit
138
Software Limit Margin
138
Zone Boundary
139
Home Return Direction
139
Home Return Offset
139
Parameters Relating to the Actuator Operating Characteristics
140
PIO Jog Speed
140
PIO Inching Distance
140
Default Speed
140
Default Acceleration/Deceleration
140
Default Positioning Band (In-Position)
140
Default Acceleration/Deceleration Mode
140
Current-Limiting Value During Home Return
141
Speed Override
141
Default Direction of Excited-Phase Signal Detection
141
Excited-Phase Signal Detection Time
141
Pole Sensing Type
141
Safety Speed
141
Automatic Servo-Off Delay Time
142
Default Standstill Mode
142
Push Speed
143
Push Completion Judgment Time
143
Enable Function
144
Polarity of Home Check Sensor Input
144
Home-Sensor Input Polarity
145
Primary-Filter Time Constant for Position Command
145
S-Motion Ratio Setting
145
Ball Screw Lead Length
146
Axis Operation Type
146
Rotational Axis Mode Selection
146
Shortcut Selection for Rotational Axis
146
Absolute Unit
147
Current-Limiting Value at Stopping Due to Missed Push-Motion
147
Parameters Relating to the External Interface
148
PIO Pattern Selection
148
Movement Command Type
149
Pause Input Disable Selection
150
Servo on Input Disable Selection
150
Home-Return Input Disable Selection
150
Operating-Mode Input Disable Selection
150
Output Mode of Position Complete Signal
151
SIO Communication Speed
151
Minimum Delay Time for Slave Transmitter Activation
151
Silent Interval Multiplier
152
Servo Gain Adjustment
153
Servo Gain Number
153
Speed Loop Proportional Gain
153
Torque Filter Time Constant
154
Current Control Range Number
154
Feed-Forward Gain
154
Pc/Teaching pendant Connection Method in Multi-Axis Configurations
155
Connection Example
155
Name and Function of each Part of the SIO Converter
156
Address Switch
158
Connection Cables
158
Detail Connection Diagram
159
Troubleshooting
161
Action to be Taken Upon Occurrence of Problem
161
Alarm Level Classification
162
Alarm Description Output Using PIO
163
Alarm Description and Cause/Action
164
Message Level Alarms
164
Cold-Start Level Alarms
167
Messages Displayed During Operation Using the Teaching pendant
170
Specific Problems
173
I/O Signals Cannot be Exchanged with the PLC
173
The ALM Lamp Illuminates When the Power Is Input
173
The SV Lamp Does Not Illuminate When the Servo on Signal Is Input after the Power was Input
173
Home Return Ends in the Middle in a Vertical Application
174
The Actuator Overshoots When Decelerated to a Stop
174
The Home and Target Positions Sometimes Shift
174
The Actuator Moves Only a Half Of, or Twice as Much As, the Specified Movement
174
The SV Lamp Blinks
174
Appendix
175
List of Specifications of Connectable Actuators
175
Positioning Sequence
188
Recording of Parameters
191
Change History
193
IAI ACON-CG Operation Manual (294 pages)
EtherNet/IP
Brand:
IAI
| Category:
Controller
| Size: 6 MB
Table of Contents
Table of Contents
5
Safety Guide
9
Handling Precautions
16
1 Overview
17
Ethernet/Ip Specifications
18
2 Acon-C/Cg, Pcon-C/Cg
19
Model Numbers
22
Ethernet/Ip Interface
23
Monitor LED Indications
24
Wiring Example
25
Setting
26
Setting the Subnet Mask
27
Communicating with the Master Station
28
I/O Signal Controls and Function
61
I/O Signal Timings
78
Operation
79
Ethernet/Ip Related Parameters
87
Troubleshooting
92
3 Pcon-Ca/Cfa
93
Model Numbers
96
Ethernet/Ip Interface
97
Wiring Example
98
Setting
99
Setting the Subnet Mask
100
Communicating with the Master Station
101
Half Direct Value Mode (Number of Occupied Bytes: 16)
112
Full Direct Value Mode (Number of Occupied Bytes: 32)
119
Remote I/O Mode 2 (Number of Occupied Bytes: 12)
130
I/O Signal Controls and Function
134
I/O Signal Timings
151
Operation
152
Ethernet/Ip Related Parameters
160
Troubleshooting
165
4 Scon-Ca
166
Model Numbers
170
Ethernet/Ip Interface
171
Monitor LED Indications
172
Wiring
173
Setting
174
Setting the IP Address
175
Communicating with the Master Station
176
Remote I/O Mode (Number of Occupied Bytes: 2)
180
Position/Simplified Direct Value Mode (Number of Occupied Bytes: 8)
185
Half Direct Value Mode (Number of Occupied Bytes: 16)
190
Full Direct Value Mode (Number of Occupied Bytes: 32)
197
Remote I/O Mode 2 (Number of Occupied Bytes: 12)
208
Position/Simplified Direct Value Mode 2 (Number of Occupied Bytes: 8)
212
Half Direct Value Mode 2 (Number of Occupied Bytes: 16)
217
Acceleration/Deceleration
221
Positioning Band
221
Speed
221
Value
221
Control Signal
222
Remote I/O Mode 3 (Number of Occupied Bytes: 12)
224
Current Position
225
Force Feedback Data
225
Half Direct Value Mode 3 (Number of Occupied Bytes: 16)
228
PLC Side Output SCON-CA Side
225
Alarm Code
231
Current Speed
231
Status Signal
231
I/O Signal Controls and Function
235
I/O Signal Timings
253
Operation
254
Ethernet/Ip Related Parameters
262
Troubleshooting
269
5 Appendix
270
Setting the PLC (1) [CX-Programmer]
271
Setting the PLC (2) [Network Configurator]
273
Checking the I/O Data on the PLC
283
Example of Connection Settings with Keyence's Master
284
Setting the PLC
285
Checking the I/O Data on the PLC
290
Change History
291
IAI ACON-CG Operation Manual (268 pages)
DeviceNet
Brand:
IAI
| Category:
Controller
| Size: 7 MB
Table of Contents
Table of Contents
5
Safety Guide
7
Operation
7
1 Overview
15
4 Scon-Ca/Cal
16
2 Acon-C/Cg, Pcon-C/Cg
16
Operation Modes and Functions
16
Model Numbers
19
Interface Specifications
20
Devicenet Interface
21
Name of each Part
21
Monitor LED Indicators
22
Selecting (Setting) the Operation Mode
23
Setting the Node Address
23
Communicating with the Master Station
24
Operation Modes and Corresponding PLC I/O Areas
24
Remote I/O Mode (Number of Occupied Channel: 1)
26
Position/Simple Direct Mode (Number of Occupied Channels: 4)
32
Half Direct Mode (Number of Occupied Channels: 8)
37
Full Direct Mode (Number of Occupied Channels: 16)
44
Remote I/O Mode 2 (Number of Occupied Channels: 6)
53
I/O Signal Controls and Functions
57
I/O Signal Timings
73
Operation
74
Devicenet Parameters
82
Troubleshooting
87
CE Mark
88
3 Acon-Ca, Pcon-Ca/Cfa, Dcon-Ca
89
Operation Modes and Functions
89
Model Numbers
92
Interface Specifications
93
Devicenet Interface
94
Name of each Part
94
Monitor LED Indicators
95
Selecting (Setting) the Operation Mode
96
Setting the Node Address
96
Communicating with the Master Station
97
Operation Modes and Corresponding PLC I/O Areas
97
Remote I/O Mode (Number of Occupied Channel: 1)
99
Position/Simple Direct Mode (Number of Occupied Channels: 4)
103
Half Direct Mode (Number of Occupied Channels: 8)
108
Full Direct Mode (Number of Occupied Channels: 16)
115
Remote I/O Mode 2 (Number of Occupied Channels: 6)
127
I/O Signal Timings
148
Troubleshooting
162
Model Numbers
168
Devicenet Interface
170
Monitor LED Indicators
171
Selecting (Setting) the Operation Mode
172
Communicating with the Master Station
173
Position/Simple Direct Mode (Number of Occupied Channels: 4)
182
Half Direct Mode (Number of Occupied Channels: 8)
187
Full Direct Mode (Number of Occupied Channels: 16)
194
Remote I/O Mode 2 (Number of Occupied Channels: 6)
205
Position/Simple Direct Mode 2 (Number of Occupied Channels: 4)
209
Half Direct Mode (Number of Occupied Channels: 8)
214
Remote I/O Mode 3 (Number of Occupied Channels: 6)
221
Half Direct Mode 3 (Number of Occupied Channels: 8)
225
I/O Signal Controls and Functions
232
I/O Signal Timings
249
Operation
250
Devicenet Parameters
258
Troubleshooting
263
5 Troubleshooting
264
6 EDS File
265
7 Change History
266
IAI ACON-CG Instruction Manual (288 pages)
MECHATROLINK-I /II, Positioner Type Controller Edition
Brand:
IAI
| Category:
Controller
| Size: 12 MB
Table of Contents
Please Read before Use
3
Construction of Instruction Manual for each Controller Model and this Manual
5
Operation Description
9
Safety Guide
9
Operation
10
Alert Indication
15
Handling Precautions
16
Interface Specifications
18
Acon-C/Cg, Pcon-C/Cg
19
Operation Modes and Functions
19
Model Names
21
Name of each Part
22
MECHATROLINK Interface
22
Monitor LED Indications
23
Home Return
51
Jog Operation
55
Inching Operation
55
I/O Signal Timings
61
Operation
62
MECHATROLINK Parameters
71
Troubleshooting
76
Status LED Indicators
76
Operation Modes and Functions
79
Model Names
83
MECHATROLINK Interface
84
Monitor LED Indications
84
Home Return
128
Jog Operation
132
Inching Operation
132
I/O Signal Timings
142
Operation
143
MECHATROLINK Parameters
152
Troubleshooting
157
Status LED Indicators
157
Operation Modes and Functions
159
Monitor LED Indications
165
I/O Signal Timings
234
Operation
235
Troubleshooting
250
Model Numbers
252
Remote I/O Mode (Number of Occupied Bytes: 2)
257
I/O Signal Controls and Function
259
Supported Commands
278
Change History
285
IAI ACON-CG First Step Manual (5 pages)
Brand:
IAI
| Category:
Controller
| Size: 1 MB
Advertisement
Related Products
IAI ACON-C
IAI acon
IAI ACON-CA
IAI ACON-CB series
IAI ACON-CB
IAI ACON-CGB
IAI ACON-CYB
IAI ACON-PLB
IAI ACON-POB
IAI ASEP
IAI Categories
Controller
Digital Camera
Gateway
Industrial Equipment
Security Camera
More IAI Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL