Sign In
Upload
Manuals
Brands
Hydac Manuals
Switch
EDS 3000
Hydac EDS 3000 Pressure Sensor Switch Manuals
Manuals and User Guides for Hydac EDS 3000 Pressure Sensor Switch. We have
4
Hydac EDS 3000 Pressure Sensor Switch manuals available for free PDF download: Operating Instructions Manual, User Manual, Operation Manual
Hydac EDS 3000 Operating Instructions Manual (84 pages)
Electronic Pressure Switch With IO-Link Interface
Brand:
Hydac
| Category:
Switch
| Size: 0 MB
Table of Contents
Deutsch
2
Table of Contents
2
1 Sicherheitshinweis
5
2 Haftungsausschluss
5
3 Funktionen des EDS 3000
5
4 Montage
5
5 Bedienelemente des EDS 3000
6
6 Betriebsarten
7
Sio Mode
7
Sdci-Mode
7
7 Parametrierung
7
8 Programmierung IM SIO Mode
8
Programmierung mit Hpg P1-000
8
Programmierung mit Zbe P1-000
8
9 Darstellung der Digitalanzeige
9
10 Ausgangsverhalten
11
Schaltausgänge
11
Twopoint Mode - Einstellung auf Schaltpunkt (SP)
11
Window Mode - Einstellung auf Fensterfunktion (Fno / Fnc)
12
Einstellbereiche für die Schaltausgänge
13
Analogausgang
13
11 Grundeinstellungen
14
Hauptmenü
14
Erweiterte Funktionen
15
12 Ändern der Grundeinstellungen
16
14 Programmierfreigabe
17
Ändern der Programmierfreigabe
17
15 Nullpunktkalibrierung
17
Rücksetzen des Spitzenwertes
17
16 Fehlermeldungen
18
17 Anschlussbelegung
18
18 Technische Daten
19
Eds 3000 mit Keramik-Sensorzelle; Absolut- und Relativdruck bis 16 Bar (500 Psi)
19
Eds 3000 mit Dünnfilm Dms-Sensorzelle
21
Relativdruck Ab 40 Bar (1000 Psi)
21
English
30
1 Safety Information
33
2 Exclusion of Liability
33
3 Functions of the EDS 3000
33
4 Installation
33
5 Control Elements of the EDS 3000
34
6 Operation Modes
35
Sio Mode
35
Sdci Mode
35
7 Parameterisation
35
8 Programming in SIO Mode
36
Programming with Hpg P1-000
36
Programming with Zbe P1-000
36
9 Reading the Digital Display
37
10 Output Signals
39
Switching Outputs
39
Twopoint Mode - Switch Point Setting (SP)
39
Window Mode - Window Function Setting (Fno / Fnc))
40
Setting Ranges for the Switching Outputs
41
Analogue Output
41
11 Basic Settings
42
Main Menu
42
Extended Functions
43
12 Changing the Basic Settings
44
13 Resetting the Peak Value
45
14 Program Enable
45
Changing the Program Enable
45
15 Zero Point Calibration
45
16 Error Messages
46
17 Pin Assignment
46
18 Technical Data
47
Eds 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure up to 16 Bar (500 Psi)
47
Eds 3000 with Thin Film Dms Sensor Cell
49
Relative Pressure Starting at 40 Bar (1000 Psi)
49
19 Order Details
51
Eds 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure up to 16 Bar (500 Psi)
51
Eds 3000 with Thin Film Dms Sensor Cell; Relative Pressure Starting at 40 Bar (1000 Psi)
52
20 Accessories
53
For Electrical Connection
53
For Mechanical Connection
53
Français
58
1 Consigne de Sécurité
61
2 Exclusion de Garantie
61
3 Fonctions de L'eds 3000
61
4 Montage
61
5 Eléments de la Face Avant de L'eds 3000
62
6 Modes de Fonctionnement
63
Mode Sio
63
Mode Sdci
63
7 Paramétrage
63
8 Programmation en Mode SIO
64
Programmation a L'aide de L'hpg P1-000
64
Programmation a L'aide du Zbe P1-000
64
9 Description de L'affichage Digital
65
10 Fonctionnement des Sorties
67
Sorties de Commutation
67
Twopoint Mode - Réglage du Seuil D'enclenchement (SP)
67
Fonction Fenêtre - Réglage Fonction Fenêtre (Fno / Fnc)
68
Réglage des Sorties de Commutation
69
Sortie Analogique
69
11 Menu de Base
70
Menu Principal
70
Fonctions Complementaires
71
12 Modifications Dans Le Menu de Base
72
14 Activation de la Programmation
73
Modification de L'autorisation de Programmation
73
15 Calibrage du Point Zéro
73
16 Messages D'erreur
74
17 Raccordement Électrique
74
18 Caractéristiques Techniques
75
Eds 3000 Avec Cellule Ceramique, Pression Absolue Et
75
Relative Jusqu'a 16 Bar (500 Psi)
75
Eds 3000 Avec Cellule Couche Mince, Pression Relativea Partir de 40 Bar (1000 Psi)
77
Advertisement
Hydac EDS 3000 Operating Instructions Manual (64 pages)
Electronic Pressure Switch
Brand:
Hydac
| Category:
Switch
| Size: 1 MB
Table of Contents
Deutsch
2
Table of Contents
2
Haftungsausschluss
5
Gewährleistung
5
Sicherheit
5
Symbole und Hinweise
5
Sicherheitshinweis
5
Bestimmungsgemäßer Gebrauch / Vorhersehbarer Fehlgebrauch
6
Verpflichtung des Betreibers vor der Inbetriebnahme
6
Personalauswahl und Qualifikation; Grundsätzliche Pflichten
6
Verpackung
7
Entsorgung
7
Lagerung
7
Transport
7
Transport, Verpackung, Lagerung
7
Organisatorische Maßnahmen
7
Funktionen des EDS 3000
8
Montage
8
Allgemeine Montagehinweise
8
Zusätzliche Montagehinweise
8
Bedienelemente des EDS 3000
9
Digitalanzeige
10
Ausgangsverhalten
10
Schaltausgänge
10
Einstellung auf Schaltpunkt (SP)
10
Einstellung auf Fensterfunktion (WIN)
11
Einstellen der Schaltpunkte und Hysteresen Bzw. Schaltwerte für die Fensterfunktion
12
Analogausgang
13
Einstellbereiche für die Schaltausgänge
13
Grundeinstellungen
14
Ändern der Grundeinstellungen
14
Aktivieren des Grundeinstellungsmenüs
14
Beenden des Grundeinstellungsmenüs
14
Übersicht der Grundeinstellungen
15
Programmierfreigabe
18
Allgemeines
18
Ändern der Programmierfreigabe
18
Ändern der Hauptprogrammierfreigabe
18
Fehlermeldungen
19
Anschlussbelegung
20
Spannungsversorgung und Ausgangsbeschaltung
20
EDS 3000 mit Keramik-Sensorzelle; Absolut- und Relativdruck bis 16 Bar
21
Technische Daten
21
EDS 3000 mit Dünnfilm-DMS-Sensorzelle; Relativdruck
23
Typenschlüssel
24
EDS 3000 mit Keramik-Sensorzelle; Absolut- und Relativdruck bis 16 Bar
24
EDS 3000 mit Dünnfilm-DMS-Sensorzelle; Relativdruck
25
Geräteabmessungen
26
Zubehör
27
Elektrischer Anschluss
27
Für die Ausgangsvarianten „1", „2" und „3
27
Für alle Ausgangsvarianten
28
Mechanischer Anschluss
29
Kontakt
31
English
34
Exclusion of Liability
37
Safety
37
Safety Information
37
Symbols and Notes
37
Warranty
37
Intended Use / Foreseeable Misuse
38
Personnel Selection and Qualification; Fundamental Obligations
38
Responsibility of the Operator before Start-Up
38
Disposal
39
Organisational Measures
39
Packaging
39
Storage
39
Transportation
39
Transportation, Packaging, Storage
39
Additional Installation Instructions
40
Assembly
40
Functions of the EDS 3000
40
General Installation Notes
40
Operating Elements of the EDS 3000
41
Digital Display
42
Output Signals
42
Switch Point Setting (SP)
42
Switching Outputs
42
Setting to Window Mode (WIN)
43
Setting the Switch Points and Hysteresis or Switching Values for Window Mode12
44
Analogue Output
45
Setting Ranges for the Switching Outputs
45
Basic Settings
46
Changing the Basic Settings
46
To Activate the Basic Settings Menu
46
To Exit the Basic Settings Menu
46
Overview of the Basic Settings
47
Changing the Main Programming Enable
50
Changing the Programming Enable
50
General
50
Program Enable
50
Error Messages
51
PIN Connection
52
Supply Voltage and Switching Outputs
52
EDS 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure
53
Technical Data
53
Up to 16 Bar
53
EDS 3000 with Thin-Film Strain Gauge; Relative Pressure
55
EDS 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure up to 16 Bar
56
Model Code
56
EDS 3000 with Thin-Film Strain Gauge; Relative Pressure
57
Device Dimensions
58
Accessories
59
Electrical Connection
59
For Use with Output Options "1", "2" and "3
59
For Use in Conjunction with All Output Models
60
Mechanical Connection
61
Contact
63
Hydac EDS 3000 User Manual (80 pages)
Electronic Pressure Switch
Brand:
Hydac
| Category:
Switch
| Size: 2 MB
Table of Contents
Deutsch
2
Table of Contents
2
Haftungsausschluss
4
Technische Sicherheit
4
Funktionen des EDS 3000
5
Montage
5
Bedienelemente des EDS 3000
6
Digitalanzeige
7
Einstellung auf Schaltpunkt (SP)
9
Einstellung auf Fensterfunktion (Fno / Fnc))
9
Schaltausgänge
9
Ausgangsverhalten
9
Analogausgang
10
Einstellbereiche für die Schaltausgänge
10
Menüführung
11
Hauptmenü
12
Erweiterte Funktionen
13
Fehlermeldung
15
Anschlussbelegung
16
Technische Daten
17
Eds 3000 mit Keramik-Sensorzelle; Absolut- und Relativdruck bis 16 Bar
17
Eds 3000 mit Dünnfilm Dms-Sensorzelle; Relativdruck Ab 40 Bar
19
Bestellangaben
20
Eds 3000 mit Keramik-Sensorzelle; Absolut- und Relativdruck bis 16 Bar
20
Eds 3000 mit Dünnfilm Dms-Sensorzelle; Relativdruck Ab 40 Bar
21
Zubehör
22
Für den Elektrischen Anschluss
22
Für den Mechanischen Anschluss
23
Geräteabmessung
25
English
28
Exclusion of Liability
30
Technical Safety
30
Functions of the EDS 3000
31
Installation
31
Control Elements of the EDS 3000
32
Digital Display
33
Output Behaviour
35
Set to Switch Point (SP)
35
Setting to Window Function (Fno / Fnc)
35
Switching Ouputs
35
Analogue Output
36
Setting Ranges for the Switch Outputs
36
Menu Navigation
37
Main Menu
38
Extended Functions
39
Error Message
41
Wiring Diagrams
42
Eds 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure up to 16 Bar
43
Technical Specifications
43
Eds 3000 with Thin Film Dms Sensor Cell; Relative Pressure Starting at 40 Bar
45
Eds 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure up to 16 Bar
46
Ordering Details
46
Eds 3000 with Thin Film Dms Sensor Cell; Relative Pressure Starting at 40 Bar
47
Accessories
48
For Electrical Connection
48
For Mechanical Connection
50
Device Dimensions
51
Français
54
Exclusion de la Garantie
56
Introduction
56
Fonctions de L'eds 3000
57
Montage
57
Eléments de la Face Avant de L'eds 3000
58
Affichage Digital
59
Fonction Seuil (SP)
61
Fonctionnement des Sorties
61
Réglage Fonction Fenêtre (Fno / Fnc)
61
Sorties de Commutation
61
Réglage des Sorties de Commutation
62
Sortie Analogique
62
Menu
63
Menu Principal
64
Fonctions Complémentaires
65
Message D'erreur
67
Raccordement Électrique
68
Caractéristiques Techniques
69
Eds 3000 Avec Cellule Ceramique, Pression Absolue Et Relative Jusqu'a 16 Bar
69
Eds°3000 Avec Cellule Couche Mince Dms
71
Pression Relative À Partir de 40 Bar
71
Code de Commande
72
Eds 3000 Avec Cellule Ceramique, Pression Absolue Et Relative Jusqu'a 16 Bar
72
Eds°3000 Cellule Couche Mince Dms, Pression Relative À Partir de 40 Bar
73
Accessoires
74
Pour Le Raccordement Electrique
74
Pour Le Raccordement Mecanique
76
Dimensions
77
Advertisement
Hydac EDS 3000 Operation Manual (24 pages)
Electronic Pressure Switch
Brand:
Hydac
| Category:
Switch
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Functions of the EDS 3000
4
Exclusion of Liability
4
2 Mounting
4
3 Operating Keys of the EDS 3000
5
4 Digital Display
6
5 Output Function
6
Switching Outputs
6
Switching Point Setting
6
Window Function Setting
7
Analog Output
7
Setting the Switching Points and Hysteresis And/Or Switching Values for the Window Function
7
Setting Ranges for the Switching Outputs
8
6 Basic Settings
9
Altering the Basic Settings
9
Summary of Basic Settings
10
7 Programming Enable
13
Altering the Operating Programming Enable
13
Altering the Main Programming Enable
13
8 Error Messages
14
9 Wiring Diagrams
15
10 Technical Specifications
16
EDS 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure ≤500 Psi
16
EDS 3000 with Thin Film DMS Sensor Cell; Relative Pressure ≥1000 Psi
18
11 Ordering Details
20
EDS 3000 with Ceramic Sensor Cell; Absolute and Relative Pressure ≤500 Psi
20
EDS 3000 with Thin Film DMS Sensor Cell; Relative Pressure ≥1000 Psi
21
12 Accessories
22
13 Dimensions
24
Advertisement
Related Products
Hydac EDS 300
Hydac EDS 1700
Hydac EDS 3400
Hydac ETS 3000 Series
Hydac ETS 3200
Hydac ETS 3800
hydac HNS 526
Hydac Categories
Water Filtration Systems
Industrial Equipment
Accessories
Control Unit
Switch
More Hydac Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL