Sign In
Upload
Manuals
Brands
Hoppecke Manuals
Battery Pack
rail power PzS
Hoppecke rail power PzS Manuals
Manuals and User Guides for Hoppecke rail power PzS. We have
1
Hoppecke rail power PzS manual available for free PDF download: Assembly & Operating Instructions
Hoppecke rail power PzS Assembly & Operating Instructions (61 pages)
Brand:
Hoppecke
| Category:
Battery Pack
| Size: 0 MB
Table of Contents
Table of Contents
4
About These Instructions
7
Target Group of this Document
7
Means of Presentation
7
Symbols and Signal Words
7
Graphic Symbols / Pictograms on the Battery System
8
Notation of Nominal Data
9
Abbreviations and Definitions
9
Warranty, Test Reports Maintenance
10
Safety Instructions
11
Sources of Danger
11
Explosive Gas Mixture
11
Electrical Voltage
13
Electrolyte
13
Toxic Substances
14
Fire
15
Improper Transport
15
Notes on Disassembly
16
Personal Protective Equipment
16
Labelling on the Product
17
Use of the Product
17
Intended Use
17
Non-Intended Use
18
Directives, Laws and Standards
19
Function and Structure
20
Battery
20
Rail | Power Pzs Cells
20
Charging Procedure for Rail | Power Pzs Cells
21
Single-Stage Charging with Constant Current, Constant Voltage (IU)
21
Two-Stage Charging with Constant Current, Constant Voltage (IU0U)
22
Technical Data
23
Technical Details
23
Ambient Conditions for Rail | Power Pzs Cells
23
Battery Charging Characteristics
24
Single-Stage, Temperature-Compensated Charging (IU Charging)
24
Two-Stage, Temperature-Compensated Charging (IU0U Charging)
26
Instructions for Transport
28
Transport of Undamaged Batteries
28
Transport of Damaged Batteries
29
Notes on Storage
30
Storage Period
31
Storage with Permanent Float Charge
32
Storage with Regular Recharging
32
Storage with Built-In Battery
32
Assembly / Commissioning
33
Checking the Delivery
34
Installation and Connection
35
Maintenance
38
Preventive Maintenance
38
Visual Inspection of the Battery
39
Check Electrolyte Level
40
Measuring the Charging Voltage
41
Clean Battery
42
Cleaning the Battery
42
Measuring the Insulation Resistance
43
Refilling Deionised / Distilled Water
45
Corrective Maintenance
46
Rail | Power Pzs Replace Cells
46
Replacing the Connector
48
Replacing the Temperature Sensor
49
Sources of Error
50
Capacity too Low
50
Insulation Resistance too Low
50
No Battery Voltage
51
Malfunction of the Temperature Sensor
51
Disassembly / Assembly of Rail | Power Pzs Cells and Accessories
52
Waste Disposal
54
Appendix
55
Additional Tools
55
Maintenance Log
57
Quarterly Maintenance Interval
58
Maintenance - Visual Inspection of the Entire Battery System
58
Maintenance - Checking the Electrolyte Level
59
Half-Yearly Maintenance Interval
60
Maintenance - Refilling Deionised / Distilled Water
60
Annual Maintenance Interval
61
Advertisement
Advertisement
Related Products
Hoppecke Rail Power FNC-HT
Hoppecke grid power V H
Hoppecke grid power V H OGi bloc
Hoppecke grid power V L
Hoppecke grid power V M
Hoppecke grid power VR L
Hoppecke grid power VR M
Hoppecke grid power VR X
Hoppecke grid power VR X FT
Hoppecke grid power VX
Hoppecke Categories
Battery Pack
Camera Accessories
Battery Charger
Inverter
Industrial Equipment
More Hoppecke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL