Haemonetics ACP 215 Manuals
Manuals and User Guides for Haemonetics ACP 215. We have
2
Haemonetics ACP 215 manuals available for free PDF download: Service Manual, Operation Manual
Haemonetics ACP 215 Service Manual (186 pages)
Brand:
Haemonetics
| Category:
Laboratory Equipment
| Size: 8 MB
Table of Contents
Publication Information
2
Copyright Notice
2
Confidential / Proprietary Notices
2
Disclaimer
2
Document Updates
3
Trademarks and Patents
3
Reader Comments
3
Rxonly
3
Haemonetics Worldwide
3
Symbols Found in this Document
4
Table of Contents
5
Introduction
11
Chapter 1 General
12
Who Should Read this Manual
12
What Is the Purpose of this Manual
12
System Overview
13
Additional Support
14
Equipment Description
15
Chapter 2
16
General
16
Specifications
17
Dimensions (Approximate)
17
Power Requirements
17
Standard Requirements
17
Environmental Conditions
18
Symbols Found on the Device
18
Disposable Sets
19
Elements of the Glycerolization Disposable Set
19
Elements of the Deglycerol-Ization Disposable Kit
20
Biohazard Waste Bag
22
Hardware Descriptions
23
Air Detectors
23
Pumps
24
Pinch Valves
26
Centrifuge
27
Fluid Detector
28
Line Sensor
28
Shaker
29
Printer
30
Card Cage
31
Cpu Pcb
31
Driver Board
31
Add Valve PCB
31
Top Deck Distribution Board
32
Centrifuge Distribution PCB
32
Centrifuge Motor Controller PCB
32
Power Entry Module
33
Power Supply
34
Control Panel
35
Dpm/Spm
36
Air Detectors
37
Principles of Operation
39
Chapter 3
40
General
40
System Start-Up Tests
41
RAM Test
41
CPU Test
41
Screen Test
41
System Tests
41
Centrifuge Cover Test
52
Utilities Mode
54
Configuration
54
Preventive Maintenance and Installation
59
Chapter 4 General
61
Preventive Maintenance Frequency
61
Initial Inspection
62
Visual Inspection
62
Ensure Initial Operational Integrity
62
Record the Program Revision Level
63
System Cleaning
64
Cleaning Agents
64
Cleaning Overview
65
Centrifuge
65
Pumps
66
Line Sensor
66
Membrane Panel
66
Deck
67
Air Sensors
67
SPM and DPM
67
Outside of Cabinet
67
Equipment Integrity Inspection
68
Electrical Connections Inspection
68
Pneumatic Connections Inspection
68
Hardware Inspection
68
Consumables Replacement
69
Filter Replacement
69
Printer Installation
70
Installing the Printer
70
Loading Paper
71
Printer Connectivity
71
Printer Test
73
Diagnostic Testing
74
Power Supply
74
Printer
74
Functional/Pump/Shaker Check
75
Rotor Durometer Test
87
Test
87
Maintenance
91
Valves Test
93
Application Mode
93
Identification
93
Protocol Selection
93
DPM and SPM Sensor Test
97
Display
98
Keyboard Test
98
Centrifuge Cover and Lock Test
98
Centrifuge Speed, Noise and Bowl Vibration Test
98
Fluid Sensor Test
99
Line Sensor Test
100
Air Detector Test
100
Leakage Current
100
Ground Continuity
101
Service Report
102
Calibration and Configuration
105
Chapter 5 Calibration Procedures
106
Pneumatic System Pressure Calibration
106
Line Sensor Signal
107
A/D Calibration
107
Market Configuration Procedure - International/North America
110
Language
118
Machine
119
Device
121
Maintenance Procedures
124
Procedure
124
Clock and Date Setting
125
Disassembly
127
Chapter 6 General
129
Cautions
129
Static Discharge
129
Notes
129
Rear Panel Assembly
130
Rear Panel
130
Fan Assembly
130
Cover Stops
130
Front Panel Assembly
131
Front Panel
131
Bag Hanger Pins
131
Tubing Guide
131
Card Cage Assembly
132
Card Cage
132
Centrifuge Distribution PCB
132
ADD Valve PCB
132
Cpu Pcb
132
Main Program Assembly
133
Driver PCB
133
Backplane PCB
133
Top Deck Assembly
134
Top Deck
134
Air Detectors, Deck
134
Line Sensor
135
Top Deck Distribution PCB
135
Pinch Valves (Front)
135
Pinch Valves (Top)
135
Air Tank
136
Pinch Valve Compressor
136
Solution and Blood Pump Assembly
136
Pump Rotor
137
SPM/DPM Detector Assembly
140
Centrifuge Assembly
142
Centrifuge
142
Cover Switch
143
Cover Knob Replacement
143
Fluid Detector Assembly
144
Top Cover Assembly
145
Top Cover
145
Membrane Panel Assembly
145
Display Distribution PCB
145
Vacuum Display
146
Membrane Panel
146
Power Entry Module
147
Line Conditioner
147
Fuse
147
Power Supply Assembly
148
Power Supply
148
Centrifuge Motor Controller PCB
148
Drain Tube Assembly
149
Drain Tube
149
Shaker
149
Troubleshooting
151
General
152
Status Messages
153
Error Messages
154
CPU Error Messages
154
Repair Parts List
173
General
174
Rohs Parts
175
Background
175
Identification of Rohs Circuit Cards
175
Identification of Rohs Compliant Devices
175
Parts List
176
System Schematics
181
System Schematic
182
Family Tree
183
Pneumatic Schematic
184
Line Sensor Fixture Schematic
185
Advertisement
Haemonetics ACP 215 Operation Manual (45 pages)
Automated Cell Processing System
Brand:
Haemonetics
| Category:
Laboratory Equipment
| Size: 1 MB
Table of Contents
Consumer Information
3
Proprietary Rights
3
Legal Disclaimer
3
Table of Contents
5
Providing an Overview
8
What Is the ACP 215 System
8
What Is the Purpose of this Manual
8
What Is Required to Perform a Procedure
8
Understanding the Use of Symbols
9
Symbols Found in this Document
9
Symbols Found on the Device
9
Symbols Found on Disposable Packaging
10
Dimensions and Weight
12
Environmental Conditions
12
Power Requirements
12
Chapter 2 Presenting the ACP 215 Equipment
16
Describing the Acp 215 Control Panel
17
Display Screen
17
Keypad
17
Describing the Acp 215 Cabinet Components
18
Centrifuge System
18
Pumps
19
Pressure Monitors
19
Blood Pump
19
Solution Pump
19
Valves
20
Air Detectors
20
Optical Line Sensor
20
Solution Bag Pole
20
Power Entry Module
21
Power Cord
21
Biohazard Waste Bag
21
Shaker
22
Printer
22
Connecting the Printer
23
Cleaning Procedures
26
Listing Tools and Cleaning Supplies
26
Exterior Surfaces, Valves, Shaker and Printer
27
Pressure Monitors
27
Air Detectors
27
Optical Line Sensor
27
Pumps
28
Fluid Detector
28
Centrifuge Components
28
Filter Screens
29
Customer Service
30
Clinical Training
30
Field Service
30
Returned Goods Authorization System
30
Handling the Acp 215 Equipment
34
Storing the Device and Material
34
Inspecting the Material
34
Installation
34
Preventing Problems During an Acp 215 Procedure
35
Understanding the Risk of Hemolysis
35
Avoiding the Consequences of Flow Restriction
35
Avoiding Bowl Misalignment
36
Avoiding Overheating Due to Mechanical Situations
36
Warnings for the Operator
37
Electrical Shock Hazards
37
Leakage Current Control
37
Mechanical Hazards/Rotating Parts
37
Power Outlet Connection
37
Communicable Disease Precautions
38
Chapter 5 Troubleshooting for the ACP 215 Device
39
Listing System Error Messages
40
Listing Interrupt Safety System Messages
43
Advertisement
Related Products
Haemonetics Cell Saver Elite
Haemonetics PCS 2
Haemonetics TEG 6s
Haemonetics Categories
Medical Equipment
Laboratory Equipment
More Haemonetics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL