Sign In
Upload
Manuals
Brands
Guildline Manuals
Measuring Instruments
6622A-XPS
Guildline 6622A-XPS Manuals
Manuals and User Guides for Guildline 6622A-XPS. We have
1
Guildline 6622A-XPS manual available for free PDF download: Operation Manual
Guildline 6622A-XPS Operation Manual (105 pages)
Automatic DCC Resistance Bridges
Brand:
Guildline
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Introduction
10
Scope
10
General Description
10
Overview
11
Principle of Operation
12
Figure 1-1 : Model 6622A Block Diagram
13
High Ohm Measurement Mode
14
Low Ohm Measurement Mode
14
Normal Ohm Measurement Mode
14
2 Installation
15
Preliminaries
15
Unpacking
15
Power Voltage Selection
15
Fuse Replacement
16
Figure 2-1 : Line Voltage Selector
16
Table 2-1 : Fuse Ratings
16
Setup and Power on
17
Incoming Inspection
17
6622A Series Front Panel Display and Controls
19
Standard Resistor Input Terminals (Bench Model Only)
19
Figure 2-2 : 6622A Front View (Bench / Rack)
19
Resistor under Test Input Terminals (Bench Model Only)
20
Guard Terminal (Bench Model Only)
20
Circuit Common Terminal (Bench Model Only)
20
Power
20
Display
20
Numeric Keypad
20
Special Keys
21
Cursor Movement Keys
21
Function Keys
21
6622A Series Rear Panel Connectors and Controls
22
IEEE-488 Interface
22
Figure 2-3 : 6622A Rear View (Bench / Rack)
22
Line Input Connector
23
Standard Resistor Input Terminals (Rack Model Only)
23
Resistor under Test Input Terminals (Rack Model Only)
23
Guard Terminal (Rack Model Only)
23
Circuit Common Terminal (Rack Model Only)
23
Ground Terminal
24
Extender Connector
24
3 Quick Measurement Guide
25
Measurement Operation Guide
25
Figure 3-1 : Resistance Measurement Response Versus Test Sample
25
Figure 3-2 : Rear Panel Connections - Normal Ohm Mode
26
Normal Ohm Mode Resistance Measurement (All 6622A Models)
26
Table 3-1 : Recommended Normal Ohm Mode Test Setups
28
Low Ohm Mode Resistance Measurement (All 6622A Models)
29
Table 3-2 : 6623 Recommended Low Ohm Mode Test Setup
31
Table 3-3 : 6623A-300 Recommended Low Ohm Mode Test Setup
31
Figure 3-3 : Rear Panel Connections - Low Ohm Mode with 6623
32
Figure 3-4 : Rear Panel Connections - Low Ohm Mode with 6623A-300
33
High Ohm Mode Resistance Measurement (6622A-XR and 6622A-XPR)
34
Table 3-4 : Recommended 100 V High Ohm Mode Test Setup
34
High Ohm Mode Resistance Measurement (6622A-HV)
35
Table 3-5 : Recommended 1000 V High Ohm Mode Test Setup
35
Figure 3-5 : Rear Panel Connections - High Ohm Mode
36
Bridgeworks Data Acquisition Software
37
4 Instrument Operation
38
Front Panel Operating Procedure
38
6622A Resistance Measurement Bridge
38
Figure 4-1 : Menu Tree - Measure/Sofcal
39
Figure 4-2 : Menu Tree - Setup
40
Figure 4-3 : Menu Tree - Measure-View
41
General Key/Display Operations
42
Base Menu
42
Basic Menu Operations
43
Menu Option-<MEASURE
43
Menu Option - <Any Other Menu but Measure
44
Base Edit/Select Menu - One Column of Data
45
Base Edit/Select Menu - Two Columns of Data
45
Operation of Select/Edit Data Menus
46
Function - <Scrn N-N
46
Function - <Edit
46
Function - <Ok
46
Title Screen
47
Main Menu
48
Measure> MENU Fn-1 (Main)
48
Measure> MENU Fn-1 (MAIN)
49
Measure> MENU Fn-1 (MAIN)
50
Setup> MENU Fn-1 (Setup_Main)
52
Profiles> MENU Fn-1 (Profiles MAIN)
52
View
53
Detail Graph
54
Detail
55
Window
55
Edit Ohms> MENU Fn-2 (Edit_Ohms MAIN)
56
Normal> MENU Fn-1 (Edit Ohms MAIN)
56
High Ohms> MENU Fn-2 (Edit Ohms_Main)
57
Low Ohms> MENU Fn-3 (Edit Ohms_Main)
58
Sofcal> MENU Fn-3 (MAIN)
59
GPIB>MENU Fn-1 (Sofcal_Main)
62
Coef Set> MENU Fn-2 (Sofcal_Main)
62
Diagnostic> MENU Fn-3 (Sofcal_Main)
63
P.O.S.T.> MENU Fn-1 (Sofcal_Main)
66
Filter> MENU Fn-2 (Sofcal_Main)
67
Datum> MENU Fn-3 (Sofcal_Main)
68
Sys Time>Menu Fn-2 (Sofcal MAIN)
68
Extender>Menu Fn-3 (Sofcalmenu)
68
PASSWORD> MENU Fn-1 (Sofcal_Main)
74
5 Verification and Calibration
75
Ratio Accuracy Verification
75
Purpose
75
Equipment Required
76
Set up
76
Verification
77
6 Troubleshooting and Maintenance
79
Introduction
79
Error Messages
79
Table 6-1 : Model 6622A Error Messages
80
Model 6622A Setup Warnings
81
Bridge Coefficients
81
Quick Ratio Check
82
Purpose
82
Equipment Required
82
Set up
82
Check Procedure
82
7 Remote Control
84
Interfaces
84
Ieee-488 (Gpib) Interface
84
Controller
85
IEEE-488 Responses
85
Interconnecting Cable and IEEE-488 Connector
85
Table 7-1 : Factory Setting-Gpib
85
Typical System
86
Address and Talk/Listen Selection
87
IEEE-488 Electrical Interface
87
IEEE-488 Input Buffering
87
Table 7-2 : Ieee-488 Connector Pin Designations
88
IEEE-488 Output Buffering
89
IEEE-488 Deadlock
89
Table 7-3 : Model 6622A Ieee-488 Device Capabilities
89
Command Language
90
General Syntax for Commands
90
General Syntax for Numbers
90
Om6622A
90
Model 6622A Remote and Local Operation
90
Model 6622A Programming Command Summary
91
8 Appendices
100
General Specifications
100
GENERAL SPECIFICATIONS (Continued)
100
Table 8-1 : General Specifications
100
Table 8-2 : General Specifications (Continued)
101
Resistance Measurement Specification
102
Table 8-3 : Resistance Measurement Specification (All 6622A Models)
104
Table 8-4 : Resistance Measurement Specification (All 6623A Models)
105
Advertisement
Advertisement
Related Products
Guildline 6622A Series
Guildline 6622A-B
Guildline 6622A-XP
Guildline 6622A-XR
Guildline 6622A-XPR
Guildline 6622A-HV
Guildline 6622T Series
Guildline 6675A
Guildline 6634A Resistance Standard
Guildline 6530 Series
Guildline Categories
Measuring Instruments
Extender
Industrial Electrical
Industrial Equipment
Decade Boxes
More Guildline Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL