Sign In
Upload
Manuals
Brands
GFA Manuals
Control Unit
DC 8010.1
GFA DC 8010.1 Manuals
Manuals and User Guides for GFA DC 8010.1. We have
1
GFA DC 8010.1 manual available for free PDF download: Installation Instructions Manual
GFA DC 8010.1 Installation Instructions Manual (51 pages)
Door control
Brand:
GFA
| Category:
Control Unit
| Size: 4 MB
Table of Contents
Table of Contents
2
Safety-Relevant Chapter
4
Explanation of Symbols
4
Target Audience of These Installation Instructions
4
Intended Use
4
Safe Operation
5
General Safety Instructions
5
Storage
5
Transport
5
Product Overview
6
Technical DC 8010.0
6
Technical Data DC 8010.1
6
Overview Housing Inside/Outside
7
Overview Display of the Door Control Unit
8
Status Displays of the Door Control
9
Mechanical Installation
10
Electrical Installation
11
Fuses
11
Connecting Limit Switch to the Door Control
12
Connecting Motor to Door Control
13
Motor Cable Conductor Size
14
Setting the Operating Voltage
15
Connecting the Door Control to the Power Grid
15
Main Switch
16
Cable Plan
17
Cable Plan for Door Drives Without FI
17
Cable Plan - Door Drives with Frequency Inverter 3
18
Cable Plan - Door Drives with Frequency Inverter 2
19
Cable Plan - Door Drives with Frequency Inverter 2~ for DC 8010.1
20
Connecting External Devices
21
Terminal Connections X - X29
21
Power Supply 24V DC
21
X2 - Safety Devices
22
X2 - Door Safety Switch
23
X3 - Emergency Stop
24
X4 - Switch for Automatic Closing
24
X5 - External Control Device
25
X6 - Photocell
26
X7 - Radio Receiver / Pull Switch
26
X8 - Switch for Intermediate Open
27
X20 / X21 - Relay Contacts
27
X29 Separate Control for Magnetic Brakes
28
X0 - Alternative Keyboard
28
Programming
28
Programming the Door Control
29
Explanation of the Programming Tables
29
Menu Items
30
P 0.1 - Operating Mode
30
P 0.2 - Output Rotating Direction
30
P 1.1 / 1.2 - Coarse Correction of Final Limit Position
31
P 1.3 - 1.5 - Fine Correction of Final Limit Positions
31
P 1.6 - Door Positions for Intermediate Open
32
P 1.7 / 1.8 - Switching Position of Relays X20/X21
32
P 2.1 - Safety Edge in Pre-Limit Area
33
P 2.3 - Automatic Closing
33
P 2.4 - Reaction of Automatic Closing to Photocell / Light Curtain
33
P 2.5 - Limiting Reversals
34
P 2.6 - Radio and Pull Switch Functions
35
P 2.7/2.8 - Relay Functions of X20/ X21
36
P 2.9 - Specifying Control Device for Intermediate Open
37
P 3.1 - Force Monitoring of Sectional Doors
37
P 3.2 - Interruption of the Photocell
38
P 3.8 - Shorten/Lengthen the Reversing Time
38
P 4.1 - 4.9 - Frequency Inverter Functions
39
P 8.5 - Setting the Maintenance Cycle Counter
40
P 8.6 - Response after Expiry of the Maintenance Cycle Counter
40
P 9.1 - Readout of Cycle Counter
41
P 9.2 - Readout of Fault Indications
41
P 9.3 - Readout of the Cycle Counter Since Last Programming Change
41
P 9.4 - Readout Software Version
42
P 9.5 - Reset to Factory Settings / Use of Gfa-Stick
42
Fault Correction
43
Fault Indications
43
Disposal
50
Advertisement
Advertisement
Related Products
GFA DC 8010
GFA DC 8010.0
GFA DALLAS
GFA Dominican Swivel Recliner
GFA 30005154
GFA 30005854
GFA ELEKTROMATEN TS 971
GFA TS 959
GFA TS 971
GFA Categories
DC Drives
Gate Opener
Industrial Equipment
Controller
Garage Door Opener
More GFA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL