Sign In
Upload
Manuals
Brands
frako Manuals
Relays
RM 9606
frako RM 9606 Power Control Relay Manuals
Manuals and User Guides for frako RM 9606 Power Control Relay. We have
2
frako RM 9606 Power Control Relay manuals available for free PDF download: Operating Instructions Manual, Commissioning And Maintenance
frako RM 9606 Operating Instructions Manual (38 pages)
Reactive Power Control Relay
Brand:
frako
| Category:
Relays
| Size: 0 MB
Table of Contents
Table of Contents
4
Summary of Instructions
7
Setting 7 Th Harmonic Threshold
7
Functions
8
Automatic Identification of Voltage and Current Source
8
Automatic Identification of the Connected Capacitor Stages
8
Automatic Setting of Switching Time Delay
9
Power Feedback
9
Installation and Connection
10
Installation
10
Voltage Connection
10
Current Transformer Connection
11
Alarm Contacts
11
Control Contacts
12
Additional Instructions
12
Commissioning
13
First Commissioning
13
Renewed Commissioning
13
Programming (Set)
14
Setting of Target Power Factor
19
Parallel Shift (PS)
20
Limitation (L)
20
Switching Time Delay
22
Automatic Stage Current (C/K) Identification "ON/OFF
22
Response Current (C/K)
23
Switching Sequence
25
Number of Contactors Used
25
Specifying Fixed Stages
25
ON/OFF Connection Identification26
26
Connection Mode
26
Setting Capacitor Discharge Time26
26
Setting Cyclic/Non-Cyclic Switching Rotation
26
Setting Threshold for Number of Switchings Alarm
26
Reseting Switching Counter
27
Current Transformer (CT) Ratio
27
Voltage Transformer Ratio
27
Setting 5 Th Harmonic Threshold
27
Setting 11 Th Harmonic Threshold
28
Harmonic Over-Current Alarm Signal
28
Suppressing the Power Factor Alarm
28
Total Kvar Display
28
Operation
29
Modes of Display
29
Manual Operation
30
Alarms
31
Technical Data
33
Trouble-Shooting
35
Advertisement
frako RM 9606 Commissioning And Maintenance (12 pages)
Power Factor Correction System
Brand:
frako
| Category:
Relays
| Size: 2 MB
Table of Contents
Table of Contents
2
Commissioning and Maintenance
3
System Location - Correct Installation, Ingress Protection and Room Temperature
3
Fuses and Cables - Supply Cable Cross Section and Rated Current of Main Fuse
3
Cable Connections - Conneting the Main Supply Cable
3
Current Transformer - Selection, Correct Arrangement and Connections
3
Reactive Power Control Relays: RM 9606, RM 2106, RM 2112, EMR 1100 S and EMR 1100 - Automatic Detection of Connection, Switching Sequence and Response Current, No-Volt Release, Etc
4
Commissioning - Switching Power on and Checking System Functions
5
Operation and Maintenance - Monitoring of Fuses, Contactors Screwed Connections, Etc
5
Troubleshooting - a Tabular Guide to Troubleshooting any Problems Arising During Commissioning
6
Check List - a Particar Help When Consulting FRAKO
7
EC Declaration of Conformitiy - LSFC, LSK
8
Assembly Instruction
9
Switch Board Cabinets
9
Power Loss
9
Set up of a Power Factor Correction System with C - Modules
9
Complete Power Factor Control Relay Packages (STR
10
Capacitor Modules, Capacitor / Reactor Modules
10
Set up of Power Factor Correction Systems for Main Voltages > 400 V
10
Circuit Diagram
11
Advertisement
Related Products
frako RM 2106
frako RM 2112
frako RM 2106/12
frako C64
frako C65
frako C66
frako C84
frako C85
frako C86
frako EMR 1100
frako Categories
Relays
Controller
Measuring Instruments
Gateway
Industrial Equipment
More frako Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL