Sign In
Upload
Manuals
Brands
Fluke Manuals
Test Equipment
7060
Fluke 7060 Manuals
Manuals and User Guides for Fluke 7060. We have
2
Fluke 7060 manuals available for free PDF download: User Manual
Fluke 7060 User Manual (75 pages)
Calibration Bath
Brand:
Fluke
| Category:
Test Equipment
| Size: 0.77 MB
Table of Contents
Table of Contents
3
1 Before You Start
9
Symbols Used
9
Table 1 International Electrical Symbols
9
Safety Information
10
Warnings
10
Cautions
12
Authorized Service Centers
13
2 Introduction
15
Figure 1 Bath Assembly
15
3 Specifications and Environmental Conditions
17
Specifications
17
Environmental Conditions
17
Warranty
18
4 Quick Start
19
Unpacking
19
Semi-Hermetic Compressor
19
Set up
19
Power
20
Figure 2 Semi-Hermetic Compressor
20
Setting the Temperature
21
5 Installation
23
Bath Environment
23
Dry-Out" Period
23
Bath Preparation and Filling
23
Probe
24
Power
24
6 Bath Use
26
General
26
Comparison Calibration
26
Calibration of Multiple Probes
27
7 Parts and Controls
28
Front Panel
28
Figure 3 Front Panel
28
Refrigeration Controls
29
Back Panel
30
Table 2 Temperature Chart
30
Figure 4 Back Panel
31
Lid
32
Figure 5 Lid Options
32
8 General Operation
34
Bath Fluid
34
Temperature Range
34
Viscosity
34
Specific Heat
34
Thermal Conductivity
35
Thermal Expansion
35
Electrical Resistivity
35
Fluid Lifetime
35
Safety
35
Cost
36
Commonly Used Fluids
36
Water
36
Ethylene Glycol
36
Methanol
36
Halocarbon 0.8
37
Mineral Oil
37
Silicone Oil
37
Fluid Characteristics Charts
37
Limitations and Disclaimer
38
About the Graph
38
Table 3 Table of Bath Fluids
39
Stirring
40
Pump
40
Figure 6 Chart of Various Bath Fluids
40
Power
41
Heater
41
Cooling
42
Temperature Controller
42
9 Controller Operation
44
Bath Temperature
44
Reset Cut-Out
44
Temperature Set-Point
46
Programmable Set-Points
46
Set-Point Value
47
Set-Point Vernier
47
Temperature Scale Units
48
Secondary Menu
49
Heater Power
49
Proportional Band
49
Figure 8 Bath Temperature Fluctuation at Various Proportional Band Settings
50
Table 4 Proportional Band - Fluid Table
51
Cut-Out
52
Controller Configuration
53
Probe Parameters Menu
53
Alpha
54
Operating Parameters
54
Cut-Out Reset Mode
54
Serial Interface Parameters
54
BAUD Rate
54
Sample Period
55
Duplex Mode
55
Linefeed
56
IEEE-488 Parameters Menu
56
IEEE-488 Address
56
Calibration Parameters
57
Cto
57
BO and BG
57
H and L
57
10 Digital Communication Interface
58
Serial Communications
58
Wiring
58
Setup
58
BAUD Rate
59
Figure 9 Serial Cable Wiring
59
Sample Period
60
Duplex Mode
60
Linefeed
60
Serial Operation
60
IEEE-488 Communication (Optional)
60
Setup
60
IEEE-488 Interface Address
61
IEEE-488 Operation
61
Interface Commands
61
Power Control Functions
61
Table 5 Interface Command Summary
62
Table 5 Interface Command Summary Continued
63
Cooling Control
64
Heater Control
64
Table 6 Serial Power Control Functions
64
Table 7 Temperature Range Control Functions
65
11 Calibration Procedure
66
Calibration Points
66
Measuring the Set-Point Error
66
Computing R0 and ALPHA
66
Calibration Example
67
Figure 10 Sample Calibration Computations
68
12 Maintenance
69
Draining the Bath
70
13 Troubleshooting
71
Troubleshooting
73
Comments
74
EMC Directive
74
Emission Testing
75
Low Voltage Directive (Safety)
75
Advertisement
Fluke 7060 User Manual (76 pages)
Calibration Bath
Brand:
Fluke
| Category:
Test Equipment
| Size: 0.61 MB
Table of Contents
Table of Contents
3
1 Before You Start
9
Symbols Used
9
Table 1 International Electrical Symbols
9
Safety Information
10
Warnings
10
Cautions
12
Authorized Service Centers
13
2 Introduction
15
Figure 1 Bath Assembly
15
3 Specifications and Environmental Conditions
16
Specifications
16
Environmental Conditions
16
4 Quick Start
18
Unpacking
18
Semi-Hermetic Compressor
18
Set up
18
Power
19
Figure 2 Semi-Hermetic Compressor
19
Setting the Temperature
20
5 Installation
22
Bath Environment
22
Dry-Out" Period
22
Bath Preparation and Filling
22
Probe
23
Power
23
6 Bath Use
25
General
25
Comparison Calibration
25
Calibration of Multiple Probes
26
7 Parts and Controls
27
Front Panel
27
Figure 3 Front Panel
27
Refrigeration Controls
28
Back Panel
29
Table 2 Cooling Temperature Chart
29
Figure 5 Lid Options
31
Lid
32
8 General Operation
33
Bath Fluid
33
Temperature Range
33
Viscosity
33
Specific Heat
33
Thermal Conductivity
34
Thermal Expansion
34
Electrical Resistivity
34
Fluid Lifetime
34
Safety
34
Cost
35
Commonly Used Fluids
35
Water
35
Ethylene Glycol
35
Methanol
35
Halocarbon 0.8
36
Mineral Oil
36
Silicone Oil
36
Fluid Characteristics Charts
37
Limitations and Disclaimer
37
About the Graph
37
Figure 6 Chart of Various Bath Fluids
38
Stirring
39
Table 3 Table of Fluids
39
Pump
40
Power
40
Heater
40
Cooling
41
Fluid Drain
42
Temperature Controller
42
9 Controller Operation
43
Bath Temperature
43
Reset Cut-Out
43
Figure 7 Controller Operation Flowchart
44
Temperature Set-Point
45
Programmable Set-Points
45
Set-Point Value
46
Set-Point Vernier
46
Temperature Scale Units
47
Secondary Menu
48
Heater Power
48
Proportional Band
48
Figure 8 Bath Temperature Fluctuation at Various Proportional Band Settings
49
Table 4 Proportional Band - Fluid Table
50
Cut-Out
51
Controller Configuration
52
Probe Parameters
52
Alpha
52
Operating Parameters
52
Cut-Out Reset Mode
53
Serial Interface Parameters
53
Baud Rate
53
Sample Period
54
Duplex Mode
54
Linefeed
55
IEEE-488 Parameters
55
IEEE-488 Address
55
Calibration Parameters
56
Cto
56
BO and BG
56
H and L
56
10 Digital Communication Interface
57
Serial Communications
57
Wiring
58
Setup
58
Baud Rate
58
Figure 9 Serial Cable Wiring
58
Sample Period
59
Duplex Mode
59
Linefeed
59
Serial Operation
59
IEEE-488 Communication (Optional)
59
Setup
59
IEEE-488 Interface Address
60
IEEE-488 Operation
60
Interface Commands
60
Power Control Functions
60
Table 5 Interface Command Summary
61
Table 5 Interface Command Summary Cont
63
Cooling Control
64
Heater Control
64
Table 6 Recommended Settings for General Operation
65
Table 7 Serial Power Control Functions
65
11 Calibration Procedure
66
Calibration Points
66
Measuring the Set-Point Error
66
Computing R and ALPHA
67
Calibration Example
67
Figure 10 Sample Calibration Computations
68
12 Maintenance
69
Draining the Bath
71
13 Troubleshooting
72
Advertisement
Related Products
Fluke 700G Series
Fluke 707Ex
Fluke 709H
Fluke 709
Fluke 701
Fluke 702
Fluke 7080
Fluke 7081
Fluke 7061
Fluke 729 Pro
Fluke Categories
Measuring Instruments
Test Equipment
Multimeter
Thermometer
Laboratory Equipment
More Fluke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL