Sign In
Upload
Manuals
Brands
Fluke Manuals
Test Equipment
5530A
Fluke 5530A Manuals
Manuals and User Guides for Fluke 5530A. We have
3
Fluke 5530A manuals available for free PDF download: Programmer's Manual, Operator's Manual, Instructions
Fluke 5530A Operator's Manual (86 pages)
Brand:
Fluke
| Category:
Test Equipment
| Size: 2 MB
Table of Contents
Table of Contents
3
Introduction
7
Contact Fluke Calibration
8
Safety Information
8
Specifications
9
Service Information
9
Operation Overview
9
Local Operation
9
Remote Operation (GPIB)
9
Remote Operation (RS-232)
9
Remote Operation (USBTMC)
10
Remote Operation (Ethernet)
10
Prepare the Product for Operation
10
Unpack and Inspect
10
Mains Voltage Selection
12
Connect to Line Power
12
Overload Protection
13
Placement and Rack Mounting
14
Cooling Considerations
14
Calibration Security Passcode
14
Features
15
Front-Panel Features
15
The Display
18
Rear-Panel Features
20
Front Panel Operation
21
Turn on the Calibrator
22
Warm up the Calibrator
22
Menus
22
Softkeys
22
DCV Screen
22
Setup Menu
23
Setup Menu > Calibration
23
Setup Menu > Instrument Setup
24
Setup Menu > System Settings
25
Remote Port Setup
26
Setup Menu > Self Test and Diagnostics
27
Setup Menu > Languages
28
Setup Menu > about
28
Function Menu
31
Function Menu > Single Output
31
Function Menu > Dual Output (Not Available on 5540A)
31
Function Menu > Measure
32
Function Menu > Scope
32
Reset the Calibrator
32
Zero the Calibrator
32
Operate and Standby Modes
32
Connect the Calibrator to a DUT
33
Recommended Cable and Connector Types
33
55XXA/DMMCAL Cable
33
When to Use EARTH and GUARD
34
Earth
34
External Guard
34
Four-Wire Versus Two-Wire Connections
35
Four-Wire Connection
35
Two-Wire Compensation
35
Compensation off
35
Cable Connections
35
RMS Versus P-P Amplitude
40
Set an Output
40
Function Menu Common Features and Functions
42
Specification Information
42
Auto Range Versus Locked Range
42
Guard Softkey
43
Sense Softkey
43
Select Waveforms
43
Set Harmonic
44
Adjust Phase - Output to Reference
44
Adjust Phase - aux to Output
44
Select Coils
45
Sync Button
46
Comp Softkey
46
Reference Junction
46
Lows Softkey
47
Thermocouple Type
47
Single Output Menu
48
Set DC Voltage Output
48
Set AC Voltage Output
48
Enter a DC Offset
48
Set a Reference
49
Enter a Duty Cycle
49
Set DC Current Output
49
Set AC Current Output
50
52120A Amplifier
50
52120A Softkey
51
Output Softkey
51
Lcomp Softkey
51
Set Resistance Output
51
Set Capacitance Output
51
Set Inductance Output (Not Available on 5540A and 5530A)
52
Set Temperature Simulation (RTD) Source
52
Set TC Source
53
Dual Output Menu (Not Available on 5540A)
53
Set DC Power Output
54
Set AC Power Output
54
Set a Dual DC Voltage Output
54
Set a Dual AC Voltage Output
55
Measure Menu
55
Measure Thermocouple Temperatures
55
Open TC Detect Softkey
55
Waveform Types
56
Sine Wave
56
Square Wave
56
Editing and Error Output Settings
57
Output Setting
58
Display the DUT Error
58
Multiply and Divide
59
Set Output Limits
59
Set Voltage and Current Limits
59
Synchronize the Calibrator Using 10 Mhz IN/OUT
60
How to Use an External 10 Mhz Clock
60
Sample Applications
60
Calibrate a 77 Series IV DMM
61
55XXA/DMMCAL Cable Assembly
61
Verification Procedure
62
Adjustment
64
5560A/5550A/5540A/5530A
64
Adjustment Procedure
64
Calibrate a Fluke 51 Thermometer
66
Verification Procedure
66
Calibrate the Thermometer
67
Maintenance
68
Update Firmware
69
Clean the Product
69
Replace the Mains Power Fuse
69
Options and Accessories
71
Rack Mount Kit
72
IEEE-488 Interface Cable
72
RS-232 Null-Modem Cables
72
55Xxa-525A/Leads
72
Scope Options
72
Oscilloscope Calibration Options
72
Oscilloscope Connections
73
Scope Menu
74
Calibrate the Voltage Amplitude on an Oscilloscope
75
Set Scope DC Voltage Output
75
Set Scope AC Voltage Output
76
Set Scope Edge Output
76
Set the Nominal Value
76
Set Scope Leveled Sine Output
76
Set Scope Marker Output
77
Set Scope Waveform Generator Output
77
Set Scope Video Trigger Output
78
Set Scope Pulse Output
78
Measure Scope Resistance
79
Measure Scope Capacitance
79
Test Overload Protection DC
79
Test Overload Protection AC
79
Error Codes
80
Advertisement
Fluke 5530A Programmer's Manual (136 pages)
Brand:
Fluke
| Category:
Test Equipment
| Size: 10 MB
Table of Contents
Table of Contents
3
Introduction
7
Contact Fluke Calibration
7
Remote Operations
8
Set up the IEEE-488 Port for Remote Control
9
IEEE-488 Interface Configuration
9
IEEE-488 Bus Communication Overview
10
USBTMC Interface
10
Set up the USBTMC Port for Remote Control
10
USBTMC Communication Overview
11
Use USBTMC to Communicate with the Product
11
RS-232 Serial Interface
12
Use the RS-232 Port for Remote Control
12
RS-232 Interface Specifications
12
Set up the RS-232 Port for Remote Control
12
RS-232 Port Setup Procedure
12
Exceptions for Serial and Ethernet Remote Control
13
Ethernet Interface
13
Set up and Connect the Ethernet Interface
13
Configure Network Security - Allowed Host IP Addresses
13
Set the Starting IP Address
14
Set the Ending IP Address
14
Set Range Enable / Disable
14
Set the IP Address
14
Select the Dynamic Host Configuration Protocol (DHCP)
14
Set a Static Internet Address
14
Configure the General Network Socket Port
15
Configure the LAN Default Gateway
15
Set the LAN Subnet Mask
15
Read the MAC Address
16
Establish an Ethernet Connection
16
Terminate an Ethernet Connection
16
Ethernet Remote Control
16
Change between Remote and Local Operation
17
Local State
17
Local with Lockout State
17
Remote State
17
Remote with Lockout State
17
RS-232 Interface Overview
19
RS-232/IEEE-488 Cables and Connectors
20
IEEE-488 Connector
20
RS-232 Serial Connector
21
IEEE-488 Interface Overview
21
USBTMC Interface Overview
24
How to Use Commands
24
Types of Commands
25
Device-Dependent Commands
25
Common Commands
25
Query Commands
25
Interface Messages (IEEE-488)
25
Compound Commands
27
Coupled Commands
27
Overlapped Commands
28
Sequential Commands
28
Combining Overlapped and Coupled Commands Within a Compound Command
29
Commands that Require You to Unsecure the Calibrator
29
Commands for RS-232/Ethernet Only
29
Commands for IEEE-488 Only
30
Command Syntax
30
Parameter Syntax Rules
31
Extra Space or Tab Characters
32
Terminators
32
Incoming Character Processing
33
Response Message Syntax
34
Check Product Status
35
Status Byte Register (STB)
35
Service Request (SRQ) Line
37
Service Request Enable Register (SRE)
38
Program the STB and SRE
38
Event Status Register (ESR)
38
Event Status Enable (ESE) Register
38
Bit Assignments for the ESR and ESE
39
Program the ESR and ESE
39
Instrument Status Register (ISR)
40
Instrument Status Change Registers
40
Instrument Status Change Enable Registers
40
Bit Assignments for the ISR, ISCR, and ISCE
40
Program the ISR, ISCR, and ISCE
41
Output Queue
42
Error Queue
42
Remote Program Examples
42
Guidelines for Programming the Calibrator
43
Writing an SRQ and Error Handler
44
Verify a Meter in the IEEE-488 Bus
45
OPC?, *OPC, and *WAI
45
Take a Thermocouple Measurement
46
Input Buffer Operation
46
Remote Commands
47
Command Summary by Function
47
Commands
57
Error Codes
130
Fluke 5530A Instructions (4 pages)
Portability Kit
Brand:
Fluke
| Category:
Test Equipment
| Size: 1 MB
Advertisement
Advertisement
Related Products
FLUKE 5500A
Fluke 5502E
Fluke 5502A
Fluke 5514B-70M
Fluke 5522A-PQ
Fluke 5522A-PQ/1G
Fluke 5522A/1GHZ
Fluke 5522A-PQ/6
Fluke 5560A
Fluke 5550A
Fluke Categories
Measuring Instruments
Test Equipment
Multimeter
Thermometer
Laboratory Equipment
More Fluke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL