Sign In
Upload
Manuals
Brands
Flintec Manuals
Measuring Instruments
DAD143.1
Flintec DAD143.1 Weight Indicator Manuals
Manuals and User Guides for Flintec DAD143.1 Weight Indicator. We have
2
Flintec DAD143.1 Weight Indicator manuals available for free PDF download: User Manual
Flintec DAD143.1 User Manual (95 pages)
Weighing Indicator
Brand:
Flintec
| Category:
Measuring Instruments
| Size: 3.94 MB
Table of Contents
Table of Contents
2
Introduction
6
Disclaimer
6
Safety Instructions
7
Specifications
8
Housing & Terminals
9
Terminals Load Cell Connection
9
Load Cell Connection
9
Terminals Power Supply
10
Terminals Service Port RS 232
10
Ethernet Based Ports
10
LED Indicators Terminal 27
11
Seal Switch
11
Logic Inputs & Outputs
12
Analog Outputs
12
Communications and Getting Started
13
Service Port
13
Command Language
13
Baud Rate
13
Getting Started Via Service Port RS 232
13
Getting Started Via Ethernet Based Port, E.g. Use Profinet Viewer
14
Menu Structure for Keybord Setup / Inspection
15
Setup Via Front Panel Keyboard
16
Keyboard Buttons
16
Use of Keyboard Buttons
16
Menu 1 System Zero
17
Menu 2 System Span
18
Menu 3 Display
19
Menu 4 Filter & Motion Detection
20
Menu 5 Analog Output
21
Menu 6 Logic Inputs
22
Menu 7 Logic Outputs
23
Menu 8 Data Communication
23
Factory Default Via Front Panel
26
Error Codes - Shown in the Front Panel Display
26
Examples of Calibration
27
Example 1 Calibration Procedure Using Weights
27
Example 2
29
Setup Via PC / PLC - Command Overview
31
Special Commands of Dad143.X Overview
34
AT Auto Transmit (for Service Port RS 232 Connection, Only)
34
AT Auto Transmit (for PLC Connection)
34
LE Last Error List (Only for RS 232 Connection)
35
Setup Via PC / PLC - Command Descriptions
36
ID, Ih, IV, Is, Sr, Rs
36
ID Get Device Identity
36
Get Firmware Version
36
IS Get Device Status
36
SR Reset Dad143.X Firmware
37
RS Read Serial Number
37
Calibration Commands
37
Cs, Su, Ru, Ft
37
CE Read TAC* Counter / Open Calibration Sequence
37
CI Set Minimum Output Value
38
MR Set Multi-Range / Multi-Interval
38
DS Set Display Step Size
39
DP Set Decimal Point Position
39
Set Calibration Zero Point
39
CG Set Calibration Gain (Span)
39
CV Calibrate Value
39
AV Show Actual Internal MV/V Value
40
ZT Zero Tracking
40
FD Reset to Factory Default Settings
40
ZR Zero Range
40
ZI Initial Zero on / off
40
TM Tare Mode
41
TN Set / Clear Non-Volatile Tare
41
ZN Set / Clear Non-Volatile Zero
41
ZM Zero Mode
41
AZ Absolute Zero Point Calibration (Ecal)
41
AG Absolute Gain Calibration (Ecal)
42
CS Save the Calibration Data
42
SU Save User Setup in EEPROM
42
RU Restore User Setup to Dad143.X
42
FT Firmware Type
42
Motion Detection Commands NR, NT
43
Filter Setting Commands FM, FL, PF, UR
43
FM Filter Mode
43
FL Filter Settings
44
PF Pre-Filter
46
UR Update Rate and Averaging
46
Taring and Zeroing Commands
46
Sz, Rz, Zn, St, Rt, Sp, Tn, Rw, Ti
46
SZ Set System Zero
46
RZ Reset Zero
46
ST Set Tare
47
RT Reset Tare
47
SP Set Preset Tare
47
TW Window for Automatic Taring
47
TI Averaging Time for Automatic Taring
48
Output Commands GG, GN, ON, GT, GS, GW, GA, GH, GM, RM, GO, GV
48
GG Get Gross Value
48
GN Get Net Value
48
GT Get Tare Value
48
GS Get ADC Sample Value
48
OF Output Format for Data String GW
49
GA Get Triggered Average Value
49
GH Get Hold Value
50
TH Trigger Hold Value
50
GM Get Peak Value
50
RM Reset of Peak Value
50
GO Get Peak to Peak Value
50
GV Get Valley Value
50
Auto-Transmit Commands
50
Sg, Sn, Sw, Sa, Sh, Sm, So, Sv
50
SG Send Gross Value Continuously
51
SN Send Net Value Continuously
51
SA Send Triggered Average Value Automatically
51
SH Send Hold Value Continuously
51
SM Send Peak Value Continuously
51
SO Send Peak to Peak Value Continuously
51
Send Valley Value Continuously
51
9.8 Logic Input Functions & Status
52
IN Read Status of the Logic Inputs
52
9.9 Logic Output Commands
52
IO Read / Modify the Status of the Logic Outputs
52
OM Control of the Logic Outputs by the Host Application
53
HT Hold Time for All Setpoints
55
9.10 Communication Setup Commands
55
Ad, Br, DX, Op, Cl, Td
55
AD Device Address
55
BR Baud Rate
55
DX Operation Mode Half-/Full-Duplex
56
OP Open Device
56
CL Close Devices
56
9.11 Analog Output
57
AA Analog Output Base
57
AH Set Analog High Level
57
AL Set Analog Low Level
57
AM Set Analog Output Mode
57
AR Set Analog Reference Value
57
9.12 Save Calibration and Setup
58
Cs, Wp, Ss, As, Gi, Pi
58
CS Save the Calibration Data
58
WP Save the Setup Parameters
58
SS Save Setpoint Parameters
58
AS Save Analog Output Parameters (Only DAD 143.1)
58
GI Get an Image File from the EEPROM
58
PI Download an Image File to the EEPROM
59
9.13 Trigger Commands
59
Sd, Mt, Ga, Te, Tr, Tl, Sa
59
SD Start Delay Time
59
MT Measuring Time
59
GA Get Triggered Average Value
59
TE Trigger Edge
60
TR Software Trigger
60
TL Trigger Level
60
SA Send Triggered Average Value Automatically
60
10 Legal for Trade Applications
61
Access to Metrological Data and Weighing Range Adjustment
61
Protection of the Metrological Data and the Scale Calibration
61
11 Calibration and Calibration Sequence
62
12 Firmware Update Program
63
FU Firmware Update
63
FD Reset to Factory Default Settings
64
Import / Export of Device Settings
64
Service Commands Overview Profinet
65
General System Command
65
PS Protocol Select
65
Ethernet Setup Commands
65
NA Network Address (Read Only)
65
NM Network Mask (Read Only)
65
NG Network Gateway (Read Only)
66
DN Device Name (Read Only)
66
MA MAC Addresses (Read Only)
66
14 Cyclic Data Transfer - Profinet
67
Data Sent from the DAD 143.X to the PLC
67
Data Package Sent from the DAD 143.X
67
Cmdstatus
67
Cmdrddata
68
Data1
68
Data2
68
Qualifier
68
Iodata
68
Datatype1
68
Datatype2
68
Data Sent from the PLC to the DAD 143.X
68
Data Package Sent to the DAD 143.X
68
Cmdwrdata
69
Index
69
Subindex
69
Sendcmd
69
Shortcmd
69
Select1
69
Select2
69
15 Acyclic Data Transfer - Profinet
70
Acyclic Read Example
70
Status Code
71
Appendix Adad 143.X GSDML File
71
18 Instructions for Program
81
Appendix B Parameter List for the DAD 143.X
82
Advertisement
Flintec DAD143.1 User Manual (87 pages)
Weighing Indicator
Brand:
Flintec
| Category:
Measuring Instruments
| Size: 3.3 MB
Table of Contents
Table of Contents
2
Introduction
6
Disclaimer
6
Safety Instructions
7
Specifications
8
Housing & Terminals
9
Terminals Load Cell Connection
9
Load Cell Connection
9
Terminals Power Supply
10
Terminals Service Port RS 232
10
Ethernet Based Ports
10
LED Indicators Terminal 27
11
Seal Switch
11
Logic Inputs & Outputs
12
Analog Outputs
12
Communications and Getting Started
13
Service Port
13
Command Language
13
Baud Rate
13
Getting Started Via Service Port RS 232
13
Getting Started Via Ethernet Based Port, E.g. Protocol for Ethernet/Ip
14
Downloading and Installing Npcap Free Edition
14
Menu Structure for Keybord Setup / Inspection
16
Setup Via Front Panel Keyboard
17
Keyboard Buttons
17
Use of Keyboard Buttons
17
Menu 1 System Zero
18
Menu 2 System Span
19
Menu 3 Display
20
Menu 4 Filter & Motion Detection
20
Menu 5 Analog Output
22
Menu 6 Logic Inputs
23
Menu 7 Logic Outputs
24
Menu 8 Data Communication
24
Factory Default Via Front Panel
27
Error Codes - Shown in the Front Panel Display
27
Examples of Calibration
28
Example 1 Calibration Procedure Using Weights
28
Example 2
30
Setup Via PC / PLC - Command Overview
32
Special Commands of Dad143.X Overview
35
AT Auto Transmit (Only for RS 232 Connection)
35
AT Auto Transmit (Only for PLC Connection)
35
LE Last Error (Command Using Only for RS 232 Connection)
36
Setup Via PC / PLC - Command Descriptions
37
ID, Ih, IV, Is, Sr, Rs
37
ID Get Device Identity
37
Get Firmware Version
37
IS Get Device Status
37
SR Reset Firmware Dad143.X
38
RS Read Serial Number
38
Calibration Commands
38
CE Read TAC* Counter / Open Calibration Sequence
38
CI Set Minimum Output Value
39
MR Set Multi-Range / Multi-Interval
39
DS Set Display Step Size
40
DP Set Decimal Point Position
40
Set Calibration Zero Point
40
CG Set Calibration Gain (Span)
40
CV Calibrate Value
40
AV Show Actual Internal MV/V Value
41
ZT Zero Tracking
41
FD Reset to Factory Default Settings
41
ZR Zero Range
41
ZI Initial Zero on / off
41
TM Tare Mode
42
TN Set / Clear Non-Volatile Tare
42
ZN Set / Clear Non-Volatile Zero
42
ZM Zero Mode
42
AZ Absolute Zero Point Calibration (Ecal)
42
AG Absolute Gain Calibration (Ecal)
43
CS Save the Calibration Data
43
SU Save User Setup in EEPROM
43
RU Restore User Setup to Dad143.X
43
FT Firmware Type
43
Motion Detection Commands NR, NT
44
Filter Setting Commands FM, FL, PF, UR
44
FM Filter Mode
44
FL Filter Settings
45
PF Pre-Filter
47
UR Update Rate and Averaging
47
Taring and Zeroing Commands
47
Sz, Rz, Zn, St, Rt, Sp, Tn, Rw, Ti
47
SZ Set System Zero
47
RZ Reset Zero
47
ST Set Tare
48
RT Reset Tare
48
SP Set Preset Tare
48
TW Window for Automatic Taring
48
TI Averaging Time for Automatic Taring
49
Output Commands
49
Gg, Gn, On, Gt, Gs, Gw, Ga, Gh, Gm, Rm, Go, Gv
49
GG Get Gross Value
49
GN Get Net Value
49
GT Get Tare Value
49
GS Get ADC Sample Value
49
OF Output Format for Data String GW
50
GA Get Triggered Average Value
50
GH Get Hold Value
51
TH Trigger Hold Value
51
GM Get Peak Value
51
RM Reset of Peak Value
51
GO Get Peak to Peak Value
51
GV Get Valley Value
51
Auto-Transmit Commands
51
Sg, Sn, Sw, Sa, Sh, Sm, So, Sv
51
SG Send Gross Value Continuously
52
SN Send Net Value Continuously
52
SA Send Triggered Average Value Automatically
52
SH Send Hold Value Continuously
52
SM Send Peak Value Continuously
52
SO Send Peak to Peak Value Continuously
52
Send Valley Value Continuously
52
Logic Input Functions & Status
53
IN Read Status of the Logic Inputs
53
Logic Output Commands
53
IO Read / Modify the Status of the Logic Outputs
53
OM Control of the Logic Outputs by the Host Application
54
HT Hold Time for All Setpoints
56
Communication Setup Commands
56
Ad, Br, DX, Op, Cl, Td
56
AD Device Address
56
BR Baud Rate
56
DX Operation Mode Half-/Full-Duplex
57
OP Open Device
57
CL Close Devices
57
Analog Output AA, AH, AL, AM, AR (Only in DAD 143.1)
58
AA Analog Output Base
58
AH Set Analog High Level
58
AL Set Analog Low Level
58
AM Set Analog Output Mode
58
AR Set Analog Reference Value
58
Save Calibration and Setup
59
Cs, Wp, Ss, As, Gi, Pi
59
CS Save the Calibration Data
59
WP Save the Setup Parameters
59
SS Save Setpoint Parameters
59
AS Save Analog Output Parameters (Only DAD 143.1)
59
GI Get an Image File from the EEPROM
59
PI Download an Image File to the EEPROM
60
Trigger Commands SD, MT, GA, TE, TR, TL, SA
60
SD Start Delay Time
60
MT Measuring Time
60
GA Get Triggered Average Value
60
TE Trigger Edge
61
TR Software Trigger
61
TL Trigger Level
61
SA Send Triggered Average Value Automatically
61
Legal for Trade Applications
62
Access to Metrological Data and Weighing Range Adjustment
62
Protection of the Metrological Data and the Scale Calibration
62
Calibration and Calibration Sequence
63
Firmware Update Program
64
FU Firmware Update
64
FD Reset to Factory Default Settings
65
Import / Export of the Device Settings
65
Service Commands Overview Ethercat
66
General System Command
66
Ps, Sr, Wp
66
PS Protocol Select
66
SR Software Reset
66
WP Write Parameters
66
Ethernet Setup Commands AP and MA
67
NA Network Address
67
AP Address Assign Protocol
67
MA MAC Addresses
67
Cyclic Data Transfer - Ethercat
68
Data Sent from the DAD 143.X to the PLC
68
Data Package Sent from the DAD 143.X
68
Cmdstatus
68
Cmdrddata
69
Data1
69
Data2
69
Qualifier
69
Iodata
69
Datatype1
69
Datatype2
69
Data Sent from the PLC to the DAD 143.X
70
Data Package Sent to the DAD 143.X
70
Cmdwrdata
70
Index
70
Subindex
70
Sendcmd
70
Shortcmd
70
Select1
71
Select2
71
Acyclic Data Transfer - Ethercat
72
Acyclic Read Example
72
Appendix Adad 143.X ESI File
72
Appendix Bsdo List for the DAD 143.X
73
Instructions for Program Ver. 1.3.0.0 or Higher
80
Advertisement
Related Products
Flintec DAD143 Series
Flintec DAS 72.1 Mark III
Flintec DSB7-7.5T
Flintec DSB7-15T
Flintec FT-30M
Flintec Categories
Amplifier
Control Unit
Monitor
Media Converter
Measuring Instruments
More Flintec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL