Sign In
Upload
Manuals
Brands
Evoqua Manuals
Measuring Instruments
WALLACE & TIERNAN DEOX/2000
Evoqua WALLACE & TIERNAN DEOX/2000 Manuals
Manuals and User Guides for Evoqua WALLACE & TIERNAN DEOX/2000. We have
2
Evoqua WALLACE & TIERNAN DEOX/2000 manuals available for free PDF download: Instruction Manual
Evoqua WALLACE & TIERNAN DEOX/2000 Instruction Manual (76 pages)
Brand:
Evoqua
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
5
1 Introduction
8
Target Groups
8
Structure of the Documentation
8
Conventions
8
2 Safety
9
Intended Use
9
General Safety Instructions
9
Warranty Conditions
10
Specific Operating Phases
10
3 Technical Data
11
Specifications
11
MICRO/2000® and DEOX/2000® Flow Block Assembly
12
Electrodes and Sensors
12
4 Description
13
Introduction
13
Versions
13
Design
14
Electronic Module
14
MICRO/2000® and DEOX/2000® Flow Block Assembly
14
5 Installation
15
Scope of Supply
15
Transport and Storage
15
Transport
15
Storage
15
Opening the Housing
15
Installation with Mounting Rail (See Drawing 50.590.100.050)
15
Installation Without Mounting Rails
15
Commissioning
16
Installation Guide
16
Pour in the Cell Sand
16
Insert the Sensor and Connect
16
Installing Reagent Hardware (See Dwg. 50.505.020.010)
17
Connecting the Sample Water
18
Connect the Device to the Power Supply
20
Mounting the Housing Covers
20
System Shut down
20
6 Setup and Control Functions
26
General Information
26
Overall Function
26
MICRO/2000® and DEOX/2000® Flow Block Assembly
26
Measurement Inputs
26
MICRO/2000® and DEOX/2000® Flow Block Assembly
27
Temperature Measurement
30
7 Operation
31
Display and Operator Controls
31
Operator Controls
31
Notes on Operation
32
Operation
32
Menu Structure
33
Calibration
33
Temperature Calibration
33
MICRO/2000® Calibration
34
Error Messages
37
Error
38
8 Maintenance
39
Maintenance Schedules
39
Check for Tightness
40
Checking the Cell Sand
40
Maintaining MICRO/2000® and DEOX/2000® Flow Block Assembly
40
Wetside Panel Removal and Replacement
40
Occlusion Ring Removal and Replacement
41
Pump Rotor, Rollers and Thrust Washer Removal and Replacement
42
Pump Tubing Units Replacement
43
Pump Bearing Replacement
46
Impeller Shaft Seal Replacement
46
Impeller Motor Removal and Replacement
47
Impeller Shaft Replacement
47
Pump Motor Removal and Replacement
48
Probe Electrolyte and Electrodes
48
Probe Cleaning, Refilling and Porous Element Replacement
49
9 Illustrations
50
10 Complete Devices , Retro Fit Kits & Spare Parts
59
Retrofit Sets
59
3-Electrode Cell MICRO/2000® with P T1000
59
3-Electrode Cell DEOX/2000® with P T1000
59
MICRO/2000® and DEOX/2000® Spare Parts and Consumables
59
MICRO/2000® and DEOX/2000® Spare Parts List
60
11 Appendix A
61
11 Appendix A
61
MICRO/2000® Flow Block Theory of Operation
61
Preparation of Reagents - MICRO/2000
61
Preparation of Ph4 Buffer
62
Preparation of Potassium Iodide Solution for MICRO/2000
62
Preparation of Potassium Iodate
63
Refilling Reagent Reservoirs
64
Selection of Reagents
64
Residual Form
64
12 Appendix B
66
DEOX/2000® Theory of Operation
66
Preparation of Reagent DEOX/2000
68
Preparation of Potassium Iodide Solution for DEOX/2000
68
13 EU Declaration of Conformity
69
Advertisement
Evoqua WALLACE & TIERNAN DEOX/2000 Instruction Manual (86 pages)
Brand:
Evoqua
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Section 1
17
Table of Contents
17
Commissioning
18
Storage
18
Installation Guide
18
Pour in the Cell Sand
18
Installation Without Mounting Rail
18
Installation with Mounting Rail
18
Opening the Housing
18
Installation
18
Insert the Sensors and Connect
19
Installing Reagent Hardware
20
Connecting the Sample Water
21
Connect the Device to the Power Supply
23
Mounting the Housing Covers
24
System Shut down
24
Top hat Rail Assembly
25
Section 2
31
Measurement Inputs
32
MICRO/2000® and DEOX/2000® Flow Block Assembly
32
Overall Function
32
MICRO/2000® and DEOX/2000® Flow Block Assembly
33
Temperature Measurement
36
Section 3
75
Preparation of Ph Buffer
76
Preparation of Reagents - MICRO/2000
76
Preparation of Potassium Iodate
77
Preparation of Potassium Iodide Solution for MICRO/2000
77
Refilling Reagent Reservoirs
78
Selection of Reagents
78
Bromine Residual Monitoring
79
Chlorine Dioxide and Potassium Permanganate Monitoring
79
Chlorine Residual Monitoring
79
Free Chlorine Monitoring
79
Residual Form
79
Interfering Residuals
80
Total Chlorine Monitoring
80
Advertisement
Related Products
Evoqua DEPOLOX
Evoqua DEPOLOX POOL COMPACT WALLACE & TIERNAN
EVOQUA WALLACE & TIERNAN DEPOLOX 400 M
EVOQUA Wallace & Tiernan SFC-SC
EVOQUA WALLACE & TIERNAN DEPOLOX 5 E
EVOQUA WALLACE & TIERNAN GMS PLUS
Evoqua WALLACE & TIERNAN DEPOLOX 5 Series
Evoqua WALLACE & TIERNAN SFC BA W3T166501
Evoqua WALLACE & TIERNAN SFC BA W3T166502
Evoqua Wallace & Tiernan Depolox 3 plus
Evoqua Categories
Measuring Instruments
Water Filtration Systems
Control Unit
Control Systems
Controller
More Evoqua Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL