Sign In
Upload
Manuals
Brands
Evoqua Manuals
Measuring Instruments
DEPOLOX
Evoqua DEPOLOX Manuals
Manuals and User Guides for Evoqua DEPOLOX. We have
2
Evoqua DEPOLOX manuals available for free PDF download: Manual, Instruction Manual
Evoqua DEPOLOX Manual (179 pages)
MEASUREMENT AND CONTROL SYSTEM
Brand:
Evoqua
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
Part
5
Safety Notes
7
Intended Use
7
Cautionary Notes and Symbols
7
General Principles
8
Notes for the Operator and Operating Personnel
8
Guarantee Conditions
9
Personnel Selection and Qualification
10
Safety Instructions During Specific Operating Phases
10
Notes on Special Dangers
11
Description
13
Versions
13
Design
14
Flow Block Assembly
15
Electronic Module
16
Sensor Measuring Module
18
Function
19
DIN Contact
20
Adaption Programme
20
Safety Functions
21
Infrared Calibration
21
Links
21
Controller Types
22
Controller Modes for Chlorine Control
23
Notes for Settings for CEDOX Control
24
Notes for Startup/Calibration of CEDOX Control
24
What Can be Achieved by Using CEDOX?
25
Combinations of Controller Modes
26
Cl2 Single Feedback Closed Loop Control
26
Cedox
26
Switching off Peak Chlorination
27
Peak-Chlorination
27
Adaption
27
Display and Operating Elements
29
Graphic Display and Operating Panel
29
Operation
29
Indicating Elements
30
System Name
30
Softkeys
31
Feed Delay
31
Positioner Feedback (Ym)
31
Sample Water Temperature
31
General Messages
32
Operating Elements
32
Notes on Operation
33
Password
33
Menu Structure
35
Main Menu
36
Top Status Line
37
Centre Display Range
37
Bottom Status Line
37
Calibration
40
Mode Settings
42
Description of the Operating Modes
43
Sensor Measuring Module Calibration
64
Chlorine Calibration
65
Free Chlorine
65
Zero Point Calibration
65
Measurement Value Calibration (DPD)
66
Total Chlorine
66
Combined Chlorine
66
Ph Calibration
67
Ph-7 Alignment
67
Slope Alignment
67
Offset Alignment
68
Redox Calibration
68
Conductivity Calibration
69
Setting Overview - Specifications
70
Errors
75
Error Messages
75
Maintenance
81
Maintenance Overview
81
Check for Tightness
81
Check the Cell Sand
81
Replacing the Cell Sand
82
Operation
5
Part
83
Cleaning/Replacing the Fine Filter
84
Installation and Commissioning
85
Scope of Supply
87
Technical Data
89
Digital Inputs
89
Measurement Inputs
89
Electronic Module
89
Relay Plug-In Card
90
Analog Outputs Plug-In Card
90
Interfaces
90
Display and Operating Unit
90
Flow Block Assembly
91
Sensor Measuring Modules
92
Transport, Storage
95
Installation Site
97
Opening the Housing
97
Installation with Mounting Rail
98
Installation Version Without Mounting Rail
99
Defining the Application
101
Functions
107
Controller Types and Control Parameters
107
Alarms
116
Adaption (Only Applies for Free Cl )
118
Completing Adaption Without Errors
121
Completing Adaption with Error
122
Special Functions
123
Flocculation Control
123
Interfaces
124
Installation / Commissioning
127
Commissioning Procedure
128
Filling Cell Sand
134
Sensor Arrangement
134
Inserting and Connecting the Sensors
135
Connecting the Sensor Cables
136
Connecting the Sample Water
137
Connecting the Sample Water Inlet
137
Connecting the Sample Water Outlet
138
Connecting the Drain
138
Examples for Sample Water with Pressure Booster Pump
139
Fitting the Fine Filter
142
Connecting the Device to the Power Supply
143
Checking the Mains Voltage
143
Mounting the Labelling Field
144
Switching the Mains Voltage over
144
Mounting the Housing Covers
145
Switching the Device on
145
Ym Calibration
147
Taking the Device out of Operation
149
Kcl Tank
149
TC1 Sensor
149
Renewed Start-Up
150
Replacing a Fuse or Battery
151
DEPOLOX Pool Electronics Module with DEPOLOX 5 Flow Cell Module
153
Installation of DEPOLOX® Pool Electronics Module with Other Flow Cell Modules
153
DEPOLOX® Pool Electronics Module with DEPOLOX® 4 Flow Cell Module
154
Sensor Measuring Modules and Spare Parts
155
Spare Parts, Pressureless Version
158
Wiring Diagrams
163
Certificates
171
Index
175
Wt.050.570.000.De.IM
176
Advertisement
Evoqua DEPOLOX Instruction Manual (104 pages)
WALLACE & TIERNAN DISINFECTION ANALYZER
Brand:
Evoqua
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Target Groups
5
Structure of the Documentation
5
Conventions
5
2 Safety
6
Intended Use
6
General Safety Instructions
6
Specific Operating Phases
7
Warranty Conditions
7
Exclusion of Liability
7
3 Description
8
General
8
Versions
8
Configuration Options
9
Overview of Sensors (des Sensors)
10
Optional Accessories
10
Electronics Module
11
DEPOLOX® 5 C Flow Cell
15
Variasens C Flow Cell
16
Y-Style Flow-Through Assembly
18
Sensors
18
Technical Data
21
4 Interfaces
28
USB Interface
28
RS485 Interface
28
Ethernet Interface
28
Modbus TCP Interface
31
5 Installation
38
Scope of Delivery
38
Transport and Storage
38
Required Ambient Conditions
38
Mechanical Installation
38
Installation of the Module
39
Removing and Fittting the Housing Cover
41
Installing the Optional Strainer
42
Connecting the Sample Water Inlet
42
Connecting the Sample Water Outlet
43
Prepare the DEPOLOX® 5 C Flow Cell
43
Prepare the Variasens C Flow Cell
45
Installing Sensors
45
Connecting Sensors
47
Electrical Installation
48
Initial Commissioning
50
Replace 4-Way Ma Output Card
51
Shut-Down
51
Start-Up
51
6 Operation
52
Display and Control Elements
52
Measurement" Menu
53
System" Menu
56
Web Visualization
64
Firmware Update
65
Calibration
66
Messages, Alarms and Errors
70
Faults and Remedies
73
7 Maintenance
74
Automatic Maintenance and Calibration Check Intervals
74
Maintenance Intervals
74
Maintenance Parts Set for Flow Cell
75
Checking for Leaks
75
Servicing the DEPOLOX® 5 C Flow Cell
75
Cleaning or Replacing the Fine Filter of Varia Sens C
77
Cleaning the Flow Rate Monitor and Non-Return Ball Valve
78
Cleaning or Replacing the Optional Strainer
79
Replacing the Fuses on the CPU Board
79
Replacing the Battery
79
Cleaning
79
8 Spare Parts, Accessories and Retrofit Kits
80
Electronics Module
80
DEPOLOX® 5 C Flow Cell
82
DEPOLOX® 5 C Flow Cell
84
Variasens C Flow Cell
86
Variasens C Flow Cell
88
Cell Body Cover, DEPOLOX® 5 C Flow Cell
90
Cell Body, Variasens C Flow Cell
91
Y-Style Flow-Through Assembly Non-Pressurized Version - W3T167442
92
Sensors, Connector-Cable Combination and Extension Cable
93
Membrane Sensors and Extension Cable
94
Accessories
95
9 Wiring Diagram
96
10 EC Declaration of Conformity and Certificate
100
Advertisement
Related Products
Evoqua DEPOLOX POOL COMPACT WALLACE & TIERNAN
Evoqua WALLACE & TIERNAN DEOX/2000
Evoqua DEPOLOX Pool E
Evoqua Defender FP Series
Evoqua E10
Evoqua IONPURE IP-MXM125
Evoqua IONPURE IP-MXM250
Evoqua IONPURE IP-MXM30
Evoqua IONPURE IP-MXM500
Evoqua IONPURE IP-MXM60
Evoqua Categories
Measuring Instruments
Water Filtration Systems
Control Unit
Control Systems
Controller
More Evoqua Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL