Sign In
Upload
Manuals
Brands
eaton Manuals
Inverter
HMX32AG02421-N
eaton HMX32AG02421-N Manuals
Manuals and User Guides for eaton HMX32AG02421-N. We have
1
eaton HMX32AG02421-N manual available for free PDF download: Installation Manual
eaton HMX32AG02421-N Installation Manual (76 pages)
Variable Frequency Drive
Brand:
eaton
| Category:
Inverter
| Size: 2.07 MB
Table of Contents
Table of Contents
5
Safety
9
Definitions and Symbols
9
Hazardous High Voltage
9
Warnings and Cautions
9
Engineering
11
Introduction
11
Figure 1. Drive System (PDS)
11
Electrical Power Network
12
Figure 2. AC Power Networks with Grounded Center Point (TN-/TT Networks)
12
Safety and Switching
14
Table 1. Identification on the Residual-Current Circuit-Breakers
14
EMC Measures
15
Figure 3. EMC Environment and Category
15
Motor and Application
16
Figure 4. Parallel Connection of Several Motors to One Frequency Inverter
16
Figure 5. Example of a Motor Ratings Plate
17
Figure 6. Star and Delta Circuit Types
17
Figure 7. V/Hz-Characteristic Curve
17
Table 2. Assignment of Frequency Inverters to Example Motor Circuit
17
Figure 8. Bypass Motor Control (Example)
18
System Overview
19
Component Identification
19
Figure 9. H-Max Series
19
Figure 10. Description of the H-Max
19
Figure 11. Block Diagram, Elements of H-Max Frequency Inverters
20
Selection Criteria
21
Figure 12. Selection Criteria
21
Proper Use
22
Maintenance and Inspection
22
Table 3. Maintenance Measures and Intervals
22
Storage
23
Service and Warranty
23
H-Max Series Overview
24
How to Use this Manual
24
Receiving and Inspection
24
Figure 13. Rating Plate
25
Figure 14. Approval Sticker
25
Figure 15. Carton Labels (U.S.)
25
Catalog Number Selection
26
Figure 16. H-Max Series Drives
26
Power Ratings and Product Selection
27
Table 4. NEMA Type 1/IP21 or NEMA Type 12/IP54
27
Table 5. NEMA Type 1/IP21 or NEMA Type 12/IP54
28
Table 6. NEMA Type 1/IP21 or NEMA Type 12/IP54
29
Table 7. H-Max Series Variable Frequency Drive Option Boards
29
Electrical Installation
30
Installation Requirements
31
Standard Mounting Instructions
31
Figure 17. Mounting Space
32
Table 8. Space Requirements for Mounting the H-Max Series VFD and Airflow
32
NEMA Type 1/12 Open Drives (1-250 Hp)
33
Figure 18. Mounting Drive Dimensions-FS4-FS7
33
Table 9. Mounting Drive Dimensions-FS4-FS7
33
Figure 19. Mounting Drive Dimensions-FS8 and FS9
34
Table 10. Mounting Drive Dimensions-FS8 and FS9
34
Power Wiring Selection
35
Table 11. Power Connection Tightening Torque
35
Table 12. Spacing between Parallel Motor Cables
35
Table 13. Maximum Cable Length by Frame Size Without DV/DT Protected C2 Ratings
35
Figure 20. Input Power and Motor Cable Stripping Lengths
36
Table 14. Input Power and Motor Cable Stripping and Wire Lengths
36
Cable Routing
37
Figure 21. Wiring the VFD
37
Control Board
41
Figure 22. H-Max Series Variable Frequency Drive
41
Figure 23. DIP Switch Functionality
42
Table 15. LED Status
42
Table 16. DIP Switch
42
Figure 24. Digital Input Ground Isolation
43
EMC Installation
44
Figure 25. EMC-Compliant Setup (Example: H-Max)
45
Figure 26. Cable Description
46
Table 17. International EMC Protection Cable Requirements
46
Figure 27. Locations of the EMC-Jumpers in Frames FS4 to FS6
47
Figure 28. Three-Phase Input Connection
48
Figure 29. Connection to Power Section
48
Figure 30. Ground Connection
48
Figure 31. Removing the Jumper, FS5 as Example
49
Figure 32. Grounding Bar Location, FS8
49
Figure 33. Removing the EMC Jumper, FS7 and FS8
50
Figure 34. Detaching the DC Grounding Bus Bar from Frame, FS7
50
Figure 35. Molex Connector Placement, FS9
51
Figure 36. Removing the EMC Jumper, FS9
51
Figure 37. Product Modified Sticker
51
Checking the Cable and Motor Insulation
52
Appendix A
53
Technical Data
53
Table 18. H-Max Technical Data
54
Table 19. Standard I/O Board
55
Table 20. Relay Board 1
56
Table 21. Relay Board 2
56
Appendix B
57
Cable Power and Motor Wiring Guidelines
57
Table 22. North America Cable and Fuse Sizes-208-240 Vac Ratings
57
Table 23. North America Cable and Fuse Sizes-380-480 Vac Ratings
58
Table 24. North America Cable and Fuse Sizes-525-600 Vac Ratings
59
Table 25. International Cable and Fuse Sizes 380-480 Vac Ratings
60
Appendix C
61
Dimension Drawings
61
Figure 38. FS4 Dimension Drawing
61
Figure 39. FS4 Dimension Drawing Flange Mount
62
Figure 40. FS5 Dimension Drawing
63
Figure 41. FS5 Dimension Drawing Flange Mount
64
Figure 42. FS6 Dimension Drawing
65
Figure 43. FS6 Dimension Drawing Flange Mount
66
Figure 44. FS7 Dimension Drawing
67
Figure 45. FS7 Dimension Drawing Flange Mount
68
Figure 46. FS8 Dimension Drawing IP00
69
Figure 47. FS8 Dimension Drawing IP2154 Flange Mount
70
Figure 48. FS8 Dimension Drawing Flange Mount
71
Figure 49. FS9 Dimension Drawing
72
Figure 50. FS9 Dimension Drawing IP2154
73
Figure 51. FS9 Dimension Drawing Flange Mount
74
Advertisement
Advertisement
Related Products
eaton HMX32AG02422-N
eaton HMX32AG01821-N
eaton HMX32AG01221-N
eaton HMX32AG04821-N
eaton HMX32AG06221-N
eaton HMX32AG08821-N
eaton HMX32AG07521-N
eaton HMX32AG01122-N
eaton HMX32AG01222-N
eaton HMX32AG01822-N
eaton Categories
UPS
Circuit breakers
Industrial Equipment
Switch
Industrial Electrical
More eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL