UPS
93E-400/400
Eaton 93E-400/400 Power Supply Manuals
Manuals and User Guides for Eaton 93E-400/400 Power Supply. We have
2
Eaton 93E-400/400 Power Supply manuals available for free PDF download: Operation Manual, Installation And Operation Manual
Eaton 93E-400/400 Installation And Operation Manual (86 pages)
UPS 300-500 kVA 380/400/415V
Brand:
Eaton
| Category:
UPS
| Size: 10 MB
Table of Contents
Table of Contents
4
List of Figures
7
List of Tables
8
Introduction
9
Figure 1-1. Eaton 93E UPS (300-500 Kva)
9
UPS Standard Features
10
Installation Features
10
Control Panel
10
Customer Interface
10
High-Efficiency Mode
10
Advanced Battery Management
10
Options and Accessories
11
External Battery Cabinet
11
Parallel System
11
Monitoring and Communication
11
Uvr
11
Battery System
12
Basic System Configurations
12
Using this Manual
12
Conventions Used in this Manual
12
Symbols, Controls, and Indicators
13
For more Information
13
Getting Help
13
Safety Warnings
14
Important Safety Instructions
14
Ups Installation Plan and Unpacking
16
Creating an Installation Plan
16
Site Preparations
16
Preparing the Site
17
Environmental and Installation Considerations
17
Table 3-1. UPS Cabinet Weights
18
Table 3-2. UPS Cabinet Clearances
18
Table 3-3. Air Conditioning or Ventilation Requirements During Full Load Operation
18
Figure 3-1 . UPS Cabinet Dimensions (Top Front \ Right \ Bottom Views)
20
Figure 3-2. UPS Cabinet Centre of Gravity
21
UPS System Power Wiring Preparation
22
Table 3-4. Input/Output Ratings and External Wiring Requirements for the Eaton 93E 300-500Kva
24
Table 3-5. UPS External Power Cable Terminations for the Eaton 93E 300-500Kva
25
Table 3-6. Recommended Input Circuit Breaker Ratings
25
Table 3-7 . Recommended Bypass and Output Circuit Breaker Ratings
25
Table 3-8. Recommended Maintenance Bypass Switch Ratings
26
Table 3-9. Recommended DC Input Circuit Breaker Rating
26
UPS System Interface Wiring Preparation
27
Inspecting and Unpacking the UPS Cabinets
28
Ups System Installation
30
Preliminary Installation Information
30
Unloading the UPS Cabinet from the Pallet
30
Figure 4-7 . REPO Terminal Block Connector Assignments
30
External Maintenance Bypass Installation
31
Figure 4-1. Removing the Shipping Bracket
31
External Battery Cabinet Installation
32
External Power Wiring Installation
33
Figure 4-2. Power Terminal Locations
34
Installing Interface Connections
35
Installing Building Alarm Connections
35
Installing External Battery Breaker with 24V UVR and Feedback Coil
35
Figure 4-3. Interface Terminal Locations
36
Installing Parallel Pull Chain and CAN Control Wiring and Connections
37
Figure 4-4. Building Alarm Terminal Block Connector Assignments
37
Table 4-1. Building Alarm Connections
37
Installing Mini-Slot Interface Connections
38
Figure 4-5. Pull Chain Terminal Block Connector Assignments
38
Table 4-2. Pull Chain Connections
38
Figure 4-6. Parallel Diagram
39
Installing a REPO Switch
40
Table 4-3. REPO Connections
40
Figure 4-8 Normally-Open REPO Switch Wiring
41
Table 4-4. Normally-Open REPO Wire Terminations
41
Initial Startup
42
Completing the Installation Checklist
42
Figure 4-9. Normally-Closed REPO Switch Wiring
42
Table 4-5. Normally-Closed REPO Wire Terminations
42
Installation Checklist
43
Parallel System Installation Checklist
44
Understanding Ups Operation
46
UPS System Overview
46
Figure 5-1. Main Elements of the UPS System
46
Single UPS
47
Modes
47
Standard Normal Mode
47
High-Efficiency Mode
48
Bypass Mode
48
Figure 5-2. Path of Current through the UPS in Standard Normal Mode
48
Figure 5-3. Path of Current through the UPS in Bypass Mode
49
Battery Mode
50
Figure 5-4. Path of Current through the UPS in Battery Mode
50
Single UPS Unit System Oneline Configurations
51
Figure 5-5. UPS System Oneline
52
Ups Operating Instructions
53
UPS Controls and Indicators
54
Figure 6-1. UPS Controls and Indicators
54
Control Panel
55
Figure 6-2. UPS Switches
55
Using the Control Panel
56
Status Indicators
56
Figure 6-3. UPS Control Panel
56
Table 6-1. Status Indicators
57
System Events
57
Status Description
57
Using the LCD and Pushbuttons
58
Figure 6-4. Parts of the LCD
58
Using the Menu
59
MIMIC Screen
59
Figure 6-5. Main Menu and MIMIC Screen
59
Table 6-2. Display Function Menu Map
59
Display Menu Operation
60
Table 6-3. Display Menu Operation
60
System Controls
62
Figure 6-6. Typical Initial Setup Screen
62
Figure 6-7 . Typical System Control Screen
63
Table 6-4. Command Menu Operation
63
Table 6-5. Typical System Status Messages
63
Single UPS Operation
64
Starting the UPS in Standard Normal Mode (Default Mode)
64
Starting the UPS in Bypass Mode
65
Transfer from Normal to Bypass Mode
65
Transfer from Bypass to Normal Mode
66
Transfer from Standard Normal Mode to HE Mode
66
Transfer from HE Mode to Standard Normal Mode
66
Transfer from Normal Mode to Internal Maintenance Bypass
67
Figure 6-8. External Maintenance Bypass Installation Diagram
67
Transfer from Internal Maintenance Bypass to Normal Mode
68
UPS and Critical Load Shutdown
68
Charger Control
68
Battery Test
69
Using the UPS LOAD off Command
69
Using the Remote Emergency Power-Off Switch
70
Multiple UPS Parallel Operation
71
Starting the Parallel UPS in Standard Normal Mode (Default Mode)
71
Starting the Parallel UPS in Bypass Mode
72
Transfer from Normal to Bypass Mode
72
Transfer from Bypass to Normal Mode
73
Single UPS Shutdown
73
Single UPS Restart
73
UPS and Critical Load Shutdown
74
Charger Control
75
Battery Test
75
Using the UPS LOAD off Command
75
Using the Remote Emergency Power-Off Switch
76
Communication
78
Mini-Slot Cards
78
Building Alarm Monitoring
78
Figure 7-1. Optional Mini-Slot Cards
78
Ups Maintenance
79
Important Safety Instructions
79
Performing Preventative Maintenance
80
DAILY Maintenance
80
MONTHLY Maintenance
80
PERIODIC Maintenance
81
ANNUAL Maintenance
81
BATTERY Maintenance
81
Installing Batteries
81
Figure 8-1. Air Filter Location
81
Recycling the Used Battery or UPS
82
Maintenance Training
82
Product Specifications
83
Model Numbers
83
Specifications
83
UPS Input
83
UPS Output
84
UPS Environmental
84
Advertisement
Eaton 93E-400/400 Operation Manual (92 pages)
300/400 kVA (380/400/415V)
Brand:
Eaton
| Category:
UPS
| Size: 11 MB
Table of Contents
Table of Contents
5
List of Figures
10
List of Tables
12
1 Introduction
13
Figure 1-1. Eaton 93E UPS (300/400 Kva)
13
Options and Accessories
14
External Battery Cabinet
14
Parallel System
14
Monitoring and Communication
15
UPS Standard Features
14
Installation Features
14
Control Panel
14
Customer Interface
14
High-Efficiency Mode
14
Advanced Battery Management
14
Basic System Configurations
15
Battery System
15
Conventions Used in this Manual
15
Using this Manual
15
For more Information
16
Getting Help
16
Symbols, Controls, and Indicators
16
2 Safety Warnings
17
Section 1-Installation
19
3 Ups Installation Plan and Unpacking
21
Ups Installation Plan and Unpacking
21
Creating an Installation Plan
21
Preparing the Site
21
Environmental and Installation Considerations
21
Table 3-1. UPS Cabinet Weights
22
Table 3-2. UPS Cabinet Clearances
22
Table 3-3. 93E Required Clearance
22
Figure 3-1. UPS Cabinet Dimensions (Front and Right Side Views)
23
Figure 3-2. UPS Cabinet Dimensions (Top and Bottom Views)
23
Figure 3-3. UPS Cabinet Centre of Gravity
24
Table 3-4. Air Conditioning or Ventilation Requirements During Full Load Operation
24
UPS System Power Wiring Preparation
25
Table 3-5.Input/Output Ratings and External Wiring Requirements for the Eaton 93E 300/400Kva
27
Table 3-6. UPS External Power Cable Terminations for the Eaton 93E 300/400Kva
28
Table 3-7. Recommended Input Circuit Breaker Ratings
28
Table 3-8. Recommended Bypass and Output Circuit Breaker Ratings
29
Table 3-9. Recommended DC Input Circuit Breaker Rating
29
UPS System Interface Wiring Preparation
30
Inspecting and Unpacking the UPS Cabinets
31
4 Ups System Installation
33
Preliminary Installation Information
33
Unloading the UPS Cabinet from the Pallet
33
External External Maintenance Bypass Installation
34
Figure 4-1. Removing the Shipping Bracket
34
External Battery Cabinet Installation
35
External Power Wiring Installation
36
Figure 4-2. Power Terminal Locations
37
Installing Interface Connections
38
Installing Building Alarm Connections
38
Figure 4-3. Interface Terminal Locations
38
Figure 4-4. Building Alarm Terminal Block Connector Assignments
39
Table 4-1. Building Alarm Connections
39
Installing Parallel Pull Chain and CAN Control Wiring and Connections
40
Figure 4-5. Pull Chain Terminal Block Connector Assignments
40
Table 4-2. Pull Chain Connections
40
Installing Mini-Slot Interface Connections
41
Figure 4-6. Parallel UPS System Connections
42
Installing a REPO Switch
43
Table 4-3. REPO Connections
43
Figure 4-8 Normally-Open REPO Switch Wiring
44
Initial Startup
45
Completing the Installation Checklist
45
Figure 4-9. Normally-Closed REPO Switch Wiring
45
Section 2-Operation
49
5 Understanding Ups Operation
51
UPS System Overview
51
Figure 5-1. Main Elements of the UPS System
51
Single UPS
52
Modes
52
Standard Normal Mode
52
High-Efficiency Mode
53
Figure 5-2. Path of Current through the UPS in Standard Normal Mode
53
Bypass Mode
54
Battery Mode
55
Single UPS Unit System Oneline Configurations
56
Figure 5-5. UPS System Oneline
57
6 Ups Operating Instructions
59
UPS Controls and Indicators
59
Control Panel
59
Figure 6-1. UPS Controls and Indicators
59
Using the Control Panel
61
Status Indicators
61
Figure 6-3. UPS Control Panel
61
Table 6-1. Status Indicators
61
System Events
62
Using the LCD and Pushbuttons
63
Figure 6-4. Parts of the LCD
63
Using the Menu
64
MIMIC Screen
64
Figure 6-5. Main Menu and MIMIC Screen
64
Table 6-2. Display Function Menu Map
64
Display Menu Operation
65
Table 6-3. Display Menu Operation
65
System Controls
67
Figure 6-6. Typical Initial Setup Screen
67
Figure 6-7. Typical System Control Screen
68
Table 6-4. Command Menu Operation
68
Table 6-5. Typical System Status Messages
68
Single UPS Operation
69
Starting the UPS in Standard Normal Mode (Default Mode)
69
Starting the UPS in Bypass Mode
70
Transfer from Normal to Bypass Mode
70
Transfer from Bypass to Normal Mode
71
Transfer from Standard Normal Mode to HE Mode
71
Transfer from HE Mode to Standard Normal Mode
71
Transfer from Normal Mode to External Maintenance Bypass
71
Transfer from External Maintenance Bypass to Normal Mode
71
UPS and Critical Load Shutdown
72
Charger Control
73
Battery Test
73
Using the UPS LOAD off Command
74
Using the Remote Emergency Power-Off Switch
75
Multiple UPS Parallel Operation
76
Starting the Parallel UPS in Standard Normal Mode (Default Mode)
76
Starting the Parallel UPS in Bypass Mode
77
Transfer from Normal to Bypass Mode
77
Transfer from Bypass to Normal Mode
78
Single UPS Shutdown
78
Single UPS Restart
79
UPS and Critical Load Shutdown
79
Charger Control
80
Battery Test
80
Using the UPS LOAD off Command
81
Using the Remote Emergency Power-Off Switch
82
7 Communication
83
Mini-Slot Cards
83
Building Alarm Monitoring
83
Figure 7-1. Optional Mini-Slot Cards
83
8 Ups Maintenance
85
Important Safety Instructions
85
Performing Preventative Maintenance
86
DAILY Maintenance
86
MONTHLY Maintenance
86
ANNUAL Maintenance
87
BATTERY Maintenance
87
Figure 8-1. Air Filter Location
87
Installing Batteries
88
Recycling the Used Battery or UPS
88
Maintenance Training
88
9 Product Specifications
89
Model Numbers
89
Specifications
89
UPS Input
89
UPS Output
90
UPS Environmental
90
Advertisement
Related Products
Eaton 93E-400/300
Eaton 93E-40
Eaton 93E40KMBSB
Eaton 93E
Eaton 93E XL
Eaton 93E 30ITC
Eaton 93E 30IAC-D
Eaton 93E-20
Eaton 93E-60/60
Eaton 93E UPS
Eaton Categories
UPS
Circuit breakers
Switch
Industrial Equipment
Industrial Electrical
More Eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL