Sign In
Upload
Manuals
Brands
DOT Manuals
Samplers
DOT-1123
DOT DOT-1123 Manuals
Manuals and User Guides for DOT DOT-1123. We have
1
DOT DOT-1123 manual available for free PDF download: Operation And Maintenance Manual
DOT DOT-1123 Operation And Maintenance Manual (86 pages)
Brand:
DOT
| Category:
Samplers
| Size: 8 MB
Table of Contents
Revision History
2
Table of Contents
3
Safety & Specifications
6
Safety Information
6
Identification
7
Figure 1: Model, Serial Number (S/N), and Part Number (P/N) Shown on Side of Sampler
7
Specifications
8
Table 1: Mechanical Specifications
8
Table 2: Electrical Specifications
8
Table 3: Fluids Specifications (in Field)
8
Table 4: Standard Filtration Specifications
9
Parts & Equipment
10
Table 5: Manufacturer-Supplied Equipment
10
Table 6: Required User-Supplied Equipment
11
Table 7: Miscellaneous Equipment (Sold-Separately)
11
Physical Setup
12
System Description
12
Figure 2: Edna Sampler with Labelled Sections (Green Boxes) and Components (Black Boxes)
13
Table 8: List of Major System Sections and Components in Figure 2
13
Assembly Instructions
16
Installation and Removal of Reagent Reservoirs
16
Figure 3: Standard Format of DOT Fluid Bag Labels
16
Table 9: Fluid Port Connections and Fluid Volumes
17
Figure 4: Fluid Bags with Shutoff Valve & Cap. Never Remove Black Cap or Purple Luer Shutoff Valve
18
Figure 5: Tools Required for a Fluid Bag Change
19
Figure 6: Edna Sampler on Cradles, with Tools
20
Figure 7: Loosening Shoulder Bolts for Removal of Reagent Case. (Right) Necessary Gap Shown
20
Figure 8: Reagent Case Rotation Direction Relative to Edna Sampler Body to Disengage Slots
21
Figure 9: Edna Sampler with Reagent Case Removed to Expose Reagent Face Plate
21
Figure 10: Fluid Reservoir Installation Using the IDEX Fitting Wrench and Luer Valve
22
Figure 11: Reagent Case and Sampler Body after Installation of Y-Splitter and Reagent Reservoirs
23
Figure 12: Reagent Case with End Cap Removed
24
Figure 13: Luer Caps Installed in All Four (4) Fluid Ports for Long Term Storage
26
Removing and Installing Filter Membranes
27
Figure 14: (Left) Filter Cassette with Nine (9) Filter Holders. (Right) Opened Filter Holder with Filter Membrane Removed
27
Figure 15: Filter Holder Disassembly with Labelled Components
28
Figure 16: Flow Direction of Sample Water through Filter Holders
29
Figure 17: Assembling the Cassette Holder
31
Figure 18: Filter Cassette Installed in Cassette Holder
32
Figure 19: Filter Holder Partially Engaged in Cassette
32
Figure 20: Filter Holder Fully Engaged in Filter Cassette; Filter Holder Is Bottomed out on O-Ring
33
Figure 21: Misaligned Filter Holder (Left) and Aligned Filter Holder (Right)
33
Installing, Replacing, & Storing Filter Cassette
35
Figure 22: Edna Sampler with Removed Filter Cassette
36
Figure 23: Edna Sampler with Attached Filter Cassette
37
Figure 24: Removing Filter Cassette from Sampler Body
38
Figure 25: Filter Cassette on Cassette Sealing Plate
39
Maintenance of Inlet and Outlet Ports
40
Figure 26: Installed Inlet Filter
41
Figure 27: Inlet Filter Housing Removed by Hand
41
Figure 28: Removing Inlet Filter Housing Using Pin Wrench and ¾" Stubby Wrench
42
Figure 29: Inlet Filter Disassembly with 2 MM T-Handle allen Key
42
Figure 30: Membrane Plate Removal, Exposing PEEK Filter
43
Figure 31: Inlet Filter Fully Disassembled. Components in Order of Assembly from Left to Right
43
Figure 32: Inlet Filter Assembly Steps 1 & 2 Shown from Left to Right
44
Figure 33: Inlet Filter Rendering, Showing the Correct Stacking of Components
44
Figure 34: Filter Final Assembly (Step 3) with T-Handle allen Key
45
Electrical & Software
46
Electrical Connections
46
Figure 35: Electrical Connections Diagram (Power & Communications)
46
Sampler Programming
50
Overview
50
Graphical User Interface (GUI) Installation
51
Connecting to Instrument (Step-By-Step)
51
Sampler Operation
52
Sleep Mode
53
Consumables
54
Sample Inlet and Outlet Ports
54
Reagents
55
Table 10: Fluid Consumption with Automated Cleaning [Sampler and Cassette Cleaning Protocol]
55
Table 11: Fluid Consumption with Automated Cleaning [Sampler Only Cleaning Protocol]
55
Updating Consumables in Graphical User Interface (GUI)
56
Figure 36: Status: Consumables Tab
56
Internal Cleaning & Priming Instrument
57
Figure 37: Edna Sampler (Right) with Fluid Collection Tray (Left)
60
Figure 38: Hose Fittings Being Installed (Left), and Hoses Running to Waste Container (Right)
60
Configure Automated Sampling
63
Trigger by Time
64
Figure 39: Automated Sampling Tab in DOT GUI [Trigger by Time]
64
Trigger by Depth (Deep-Rated Units Only)
65
Figure 40: Automated Sampling Tab in DOT GUI [Trigger by Depth]
65
Scheduling Automated Sample Captures
66
Manual Sampling
67
Figure 41: Manual Sampling Tab in DOT GUI
67
Sampler Deployment
68
Operating Temperature Conditions
68
Length of Deployment
68
Sampler Retrieval
70
Maintenance & Care
73
Electrical Connections
73
Anode Replacement
74
Warranty
75
Troubleshooting
75
Appendices
76
Appendix A: Mechanical Drawings
76
Appendix B: Electrical Pinouts
81
Table 12: Sampler Power and Comms Pinout: 8-Pin Male (from Sampler)
81
Table 13: Y-Connector Comms Cable Pinout: 8-Pin Female (from Y-Splitter)
81
Table 14: Y-Splitter Power Cable Pinout: 6-Pin Male (from Y-Splitter)
81
Appendix C: Energy Calculations [Shallow-Rated Units]
82
Appendix D: Refilling Reagent Reservoirs
84
Advertisement
Advertisement
Related Products
DOT DOT-1548
DOT DOT-1549
DOT DOTH-300
DOT DOTH-500
DOT DOTR-900
DOT DOT-500
DOT DW01
DOT DM-01
DOT DPA320A
DOT eDNA Sampler
DOT Categories
PDA
Skateboards & Longboards
Cell Phone
Barcode Reader
Personal Care Products
More DOT Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL