Sign In
Upload
Manuals
Brands
Cray Manuals
Desktop
XD1
User Manuals: Cray XD1 Supercomputer
Manuals and User Guides for Cray XD1 Supercomputer. We have
2
Cray XD1 Supercomputer manuals available for free PDF download: Manual, Hardware Installation And Upgrade
Cray XD1 Manual (164 pages)
Brand:
Cray
| Category:
Desktop
| Size: 1 MB
Table of Contents
Table of Contents
7
Preface
15
Accessing Product Documentation
15
Conventions
16
Reader Comments
17
Cray User Group
17
Cray XD1 Support
18
Introduction [1]
19
Who Should Read this Manual
19
Scope of this Manual
19
How this Manual Is Organized
19
Related Publications
20
WEEE Compliance Statement
21
Table 1. Related Publications
21
Figure 1. WEEE Compliance Statement
22
Interconnecting the Rapidarray Network [2]
23
Overview
23
Handling Rapidarray Cables
23
ESD Precautions
23
Bend Radii
24
Connecting Rapidarray Cables
24
Table 2. Minimum Bend Radii for Rapidarray Cables
24
Figure 2. Rapidarray Cable Connector
24
Disconnecting Rapidarray Cables
25
Procedure 1: to Disconnect a Rapidarray Cable
25
Figure 3. Rapidarray Cable Connection
25
Cabling the Topology
26
Preparing to Cable Your System
26
Routing and Securing the Cables for Your System
27
Procedure 2: to Route and Secure Rapidarray Cables
27
Figure 4. Rapidarray Cable Bundles
28
Cabling Direct-Connect Topologies [3]
29
Overview
29
Direct-Connect Topology
29
Equipment Required
30
Time Required
30
Installation Order
30
Direct-Connect Topology: Two Chassis
30
Figure 5. Direct-Connect Topology-High-Level
30
Table 3. Port Mapping for a 2-Chassis Direct-Connect System
31
Direct-Connect Topology: Three Chassis
32
Figure 6. Direct-Connect Topology: 2 Chassis
32
Table 4. Port Mapping for a 3-Chassis Direct-Connect System
33
Direct-Connect Topology: Four Chassis
35
Figure 7. Direct-Connect Topology: 3 Chassis
35
Table 5. Port Mapping for a 4-Chassis Direct-Connect System
36
Direct-Connect Topology: Five Chassis
38
Figure 8. Direct-Connect Topology: 4 Chassis
38
Table 6. Port Mapping for a 5-Chassis Direct-Connect System
39
Figure 9. Direct-Connect Topology: 5 Chassis
42
Direct-Connect Topology: Six Chassis
43
Table 7. Rapidarray Cables for 6-Chassis Direct-Connect System
43
Table 8. Port Mapping for a 6-Chassis Direct-Connect System
43
Figure 10. Direct-Connect Topology: 6 Chassis
47
Direct-Connect Topology: Seven Chassis
48
Table 9. Rapidarray Cables for a 7-Chassis Direct-Connect System
48
Table 10. Port Mapping for a 7-Chassis Direct-Connect System
48
Figure 11. Direct-Connect Topology: 7 Chassis
52
Direct-Connect Topology: Eight to Thirteen Chassis
53
Eight- to Thirteen-Chassis Connections
53
Set a Connections
53
Table 11. Rapidarray Cables for an 8- to 13-Chassis Direct-Connect System
53
Table 12. Port Mapping for a 13-Chassis Direct-Connect System-Set a
54
Figure 12. Direct-Connect Topology: 8 to 13 Chassis-Set a
60
Set B Connections
61
Table 13. Port Mapping for an 8-Chassis Direct-Connect System-Set B
61
Table 14. Port Mapping for a 9-Chassis Direct-Connect System-Set B
63
Table 15. Port Mapping for a 10-Chassis Direct-Connect System-Set B
64
Table 16. Port Mapping for an 11-Chassis Direct-Connect System-Set B
65
Table 17. Port Mapping for a 12-Chassis Direct-Connect System-Set B
67
Figure 13. Direct-Connect Topology: 8 to 13 Chassis-Set B
68
Cabling Fat Tree Topologies: Introduction [4]
69
Overview
69
Figure 14. Fat Tree Topology
69
Base Configurations and Supported Configurations
70
External Switch Chassis
70
Number of Switch Chassis
71
Switch Chassis Port Numbering
71
Table 18. Switch Chassis in Standard Base Fat Tree Configurations
71
Figure 15. Port Numbers on 24-Port Switch Chassis
71
Equipment Required
72
Figure 16. Leaf Blade and Port Numbers on 144-Port Switch Chassis
72
Cabling a 12-Chassis Fat Tree [5]
73
Overview
73
Table 19. Rapidarray Cables for a 12-Chassis Fat Tree System
73
Figure 17. Fat Tree Topology: 12 Chassis
74
Port Groups (Fabrics)
75
Installation Order
75
Port Mapping Details
75
Fabric a
75
Table 20. Fat Tree Topology Port Groups: 12 Chassis
75
Table 21. Port Mapping for a 12-Chassis Fat Tree System-Fabric a
76
Fabric B
77
Table 22. Port Mapping for a 12-Chassis Fat Tree System-Fabric B
77
Fabric C
79
Table 23. Port Mapping for a 12-Chassis Fat Tree System-Fabric C
79
Fabric D
80
Table 24. Port Mapping for a 12-Chassis Fat Tree System-Fabric D
80
Cabling a 24-Chassis Fat Tree [6]
83
Overview
83
Table 25. Rapidarray Cables for a 24-Chassis Fat Tree System
83
Figure 18. Fat Tree Topology: 24 Chassis
84
Port Groups (Fabrics)
85
Installation Order
85
Port Mapping Details
85
Fabric a
85
Fabric C1
85
Fabric C2
85
Fabric D1
85
Fabric D2
85
Table 26. Fat Tree Topology Port Groups: 24 Chassis
85
Table 27. Port Mapping for a 24-Chassis Fat Tree System-Fabric a
86
Fabric B
87
Table 28. Port Mapping for a 24-Chassis Fat Tree System-Fabric B
87
Table 29. Port Mapping for a 24-Chassis Fat Tree System-Fabric C1
89
Table 30. Port Mapping for a 24-Chassis Fat Tree System-Fabric C2
91
Table 31. Port Mapping for a 24-Chassis Fat Tree System-Fabric D1
92
Table 32. Port Mapping for a 24-Chassis Fat Tree System-Fabric D2
94
Cabling a 36-Chassis Fat Tree [7]
97
Overview
97
Figure 19. Logical View of 36-Chassis Fat Tree Configuration
97
Figure 20. Cabinet Layout of 36-Chassis System (Front View)
98
Cable Inventory
99
Table 33. Rapidarray Cables for a 36-Chassis Fat Tree System
99
Figure 21. Cabinet Layout of 36-Chassis System (Rear View)
99
Port Groups (Fabrics)
100
Figure 22. Port Groups and Port Mapping Rules for 36-Chassis System
100
Installation Order
101
Port Mapping Details
101
Table 34. Fat Tree Topology Port Groups: 36 Chassis
101
Fabric a
102
Table 35. Port Mapping for a 36-Chassis Fat Tree System-Fabric a
102
Fabric B
105
Table 36. Port Mapping for a 36-Chassis Fat Tree System-Fabric B
105
Fabric C
108
Table 37. Port Mapping for a 36-Chassis Fat Tree System-Fabric C
108
Fabric D
111
Table 38. Port Mapping for a 36-Chassis Fat Tree System-Fabric D
111
Fabric E
114
Table 39. Port Mapping for a 36-Chassis Fat Tree System-Fabric E
114
Fabric F
117
Table 40. Port Mapping for a 36-Chassis Fat Tree System-Fabric F
117
Cabling a 48-Chassis Fat Tree [8]
121
Overview
121
Figure 23. Logical View of 48-Chassis Fat Tree Configuration
121
Figure 24. Cabinet Layout of 48-Chassis System (Front View)
122
Figure 25. Cabinet Layout of 48-Chassis System (Rear View)
122
Cable Inventory
123
Port Groups (Fabrics)
123
Table 41. Rapidarray Cables for a 48-Chassis Fat Tree System
123
Table 42. Fat Tree Topology Port Groups: 48 Chassis
124
Figure 26. Port Groups and Port Mapping Rules for 48-Chassis System
124
Installation Order
125
Port Mapping Details
125
Fabric a
126
Table 43. Port Mapping for a 48-Chassis Fat Tree System-Fabric a
126
Fabric B
129
Table 44. Port Mapping for a 48-Chassis Fat Tree System-Fabric B
129
Fabric C
132
Table 45. Port Mapping for a 48-Chassis Fat Tree System-Fabric C
132
Fabric D
135
Table 46. Port Mapping for a 48-Chassis Fat Tree System-Fabric D
135
Fabric E
138
Table 47. Port Mapping for a 48-Chassis Fat Tree System-Fabric E
138
Fabric F
141
Table 48. Port Mapping for a 48-Chassis Fat Tree System-Fabric F
141
Fabric G
144
Table 49. Port Mapping for a 48-Chassis Fat Tree System-Fabric G
144
Fabric H
147
Table 50. Port Mapping for a 48-Chassis Fat Tree System-Fabric H
147
Configuring Nonstandard Fat Trees [9]
151
Choosing the Base Configuration
151
Example 1: Base Configuration for a 28-Chassis System
151
Depopulation Rules
151
Depopulating Cray XD1 Chassis
151
Example 2: 28-Chassis System: Removing Chassis from 48-Chassis Configuration
152
Depopulating Switch Chassis: General
152
Switch Chassis Selected from 24-Chassis Configuration
152
Depopulating Cables
152
Depopulating 24-Port Switch Chassis
152
Minimum Number of 144-Port Switch Chassis
152
Depopulating Leaf Blades in 144-Port Switch Chassis
152
Minimum Number of Cray XD1 Chassis
153
Systems with 24-Port Switches
153
Example 4: Minimum Number of Chassis with 24-Port Switches
153
Systems with 144-Port Switches
154
Example 5: Minimum Number of Chassis with 144-Port Switches
154
Cabling Remaining Components
154
Appendix A ID Information
155
Recording ID Information
155
Chassis Ids
155
Table 51. Chassis Ids (Direct-Connect Systems)
155
Table 52. Chassis Ids (Fat Tree Systems)
156
Switch Chassis Ids
157
Glossary
159
Advertisement
Cray XD1 Hardware Installation And Upgrade (85 pages)
Brand:
Cray
| Category:
Desktop
| Size: 2 MB
Table of Contents
Table of Contents
7
Preface
13
Accessing Product Documentation
13
Conventions
14
Reader Comments
15
Cray User Group
15
Introduction [1]
17
Who Should Read this Manual
17
Scope of this Manual
17
Units of Measurement
17
Tables
18
Related Publications
18
Table 1. Related Publications
18
Regulatory Compliance Statements
19
EMC Compliance Statements
19
United States
19
Canada
20
Figure 1. on Symbol
20
Figure 2. Standby Symbol
20
Figures
20
Safety Compliance: Warnings and Cautions
20
Sicherheitshinweis
22
Figure 3. VCCI-A Compliance Statement
23
VCCI-A Compliance Statement
23
WEEE Compliance Statement
23
Figure 4. WEEE Compliance Statement
24
Overview of Cray XD1 Installation [2]
25
About the Cray XD1 Computer
25
Cray XD1 Chassis
25
Figure 5. Cray XD1 Chassis, Front View
26
Figure 6. Cray XD1 Chassis, Rear View
26
Cray XD1 System
27
Interprocessor Communications
27
Overview of the Installation Process
27
Table 2. Overview of the Installation Process
28
Table 3. Overview of the Upgrade Process
29
Required Tools and Equipment
30
Receiving Equipment [3]
31
Acclimating Equipment
31
Checking Inventory
31
Unpacking a System Cabinet
31
Procedure 1: to Unpack a System Cabinet
32
Figure 7. Cabinet Shipping Crate
32
Figure 8. Installing the Ramp
34
Installing and Preparing a Cabinet [4]
35
Removing and Installing the Cabinet Side Panels
35
Procedure 2: to Remove Cabinet Side Panels from a 42-VU Cabinet
35
Procedure 3: to Install Cabinet Side Panels on a 42-VU Cabinet
36
Procedure 4: to Remove Cabinet Side Panels from a 21-VU Cabinet
36
Procedure 5: to Install the Cabinet Side Panels on a 21-VU Cabinet
36
Removing the Chassis Shipping Brackets
36
Procedure 6: to Remove the Chassis Shipping Brackets
37
Figure 9. Chassis Shipping Bracket, Right Side
37
Positioning a Cabinet
38
Routing Power Circuits
39
Routing Power Circuits for Cray XD1 Chassis
39
Routing Power Circuits for External Switches
41
Installing the Ganging Kits
42
Procedure 7: to Install a Ganging Kit
42
Stabilizing a Cabinet
44
Installing the Anti-Tip Foot
45
Procedure 8: to Install the Anti-Tip Foot
45
Installing the Cabinet Trim on a 42-VU Cabinet
46
Procedure 9: to Install the Cabinet Trim
46
Connecting Cables to the Cray XD1 System [5]
49
Cabling Guidelines
49
General Cabling Guidelines
49
Cable Routing Guidelines
49
Routing Ethernet and Fibre Channel Cables
50
Interconnecting the Cray XD1 Internal Networks
51
Interconnecting the Rapidarray Fabrics
52
Interconnecting the Supervisory Network
52
Overview of the Supervisory Network
52
Connecting 100-Mbps Ethernet Ports
52
Connecting the Cray XD1 System to External Devices
53
PCI-X Card Connections and Numbering
54
Table 4. PCI-X Card Connections to Nodes
54
Connecting to a LAN Via NIC Ports
55
Procedure 10: to Connect to a LAN Via a NIC Port
55
Connecting to External Storage Devices
56
Fibre Channel Cable Bend Radii
56
Connecting Fibre Channel Ports
56
Procedure 11: to Connect Fibre Channel Ports
56
Connecting the JTAG Interface Card to a Personal Computer
57
Procedure 12: to Connect the JTAG Interface Card
58
Connecting Power Cables
59
Procedure 13: to Connect Power Cables
59
Upgrading a Cray XD1 System [6]
61
Upgrading a Cabinet
61
Planning the Layout of Chassis and Switches
61
Installing the Slide Rail Hardware
61
Routing Power Circuits
62
Installing a Chassis in a Cabinet
62
Safety Guidelines
62
Before You Begin
63
Mounting a Chassis in a Cabinet
63
Procedure 14: to Mount a Chassis in a Cabinet
63
Reseating or Installing Disk Blades
64
Procedure 15: to Reseat Disk Blades
65
Procedure 16: to Install Disk Blades
66
Installing External Switches
67
Installing an Ethernet Switch
68
Procedure 17: to Install an Ethernet Switch
68
Installing a 24-Port Rapidarray Switch
69
Procedure 18: to Install 24-Port Rapidarray Switches
69
Installing Cabinet Blanking Panels
74
Removing a Chassis from a Cabinet
75
Procedure 19: to Remove a Chassis from a Cabinet
75
Appendix A Installation Checklist
77
Table 5. Installation Checklist
77
Glossary
79
Index
83
Advertisement
Related Products
Cray X-MP
Cray X-MP Series
Cray XC30-LC
Cray XC40-LC
Cray 22
Cray 24
Cray CRAY-1
CRAY CX1
Cray J90 Series
Cray J916
Cray Categories
Desktop
Server
Industrial Equipment
Storage
Air Conditioner
More Cray Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL