CS475
Campbell CS475 Display Cap Manuals
Manuals and User Guides for Campbell CS475 Display Cap. We have
2
Campbell CS475 Display Cap manuals available for free PDF download: Instruction Manual
Campbell CS475 Instruction Manual (50 pages)
Radar Water Level Sensor
Brand:
Campbell
| Category:
Accessories
| Size: 1.86 MB
Table of Contents
Table of Contents
7
1 Introduction
11
2 Precautions
11
3 Initial Inspection
12
4 Quickstart
12
5 Overview
14
Components and Hardware
15
CS475, CS476, and CS477
15
Components and Hardware (See TABLE 5-1 for Description of Labels)
16
Description of Components and Hardware Labels
16
6 Specifications
17
Reference Line for Measurement Range
17
Radar Unit
18
Environmental
18
Physical
18
CS475 Dimensions
19
CS476/CS477 Dimensions
20
7 Installation
21
Site Selection
21
Mount and Align the Sensor
21
Radiation Beam Spread for CS475 (10° Beam Angle)
22
Radiation Beam Spread for CS476/CS477 (8° Beam Angle)
22
Description of Polarization Markings Labels
23
Wiring to Datalogger
24
Built-In Self Test (BIST)
24
Datalogger Programming
24
Wire Color, Function, and Datalogger Connection
24
Sdi12Recorder() Instruction
25
8 Operation
25
Default Settings
25
Sensor Measurement
26
9 Diagnostics, Repair, and Maintenance
26
Testing Procedure
26
SDI-12 Commands
26
Cyclic Redundancy Check
27
Diagnostics and Repair
27
No Measured Value Available - Error E013
28
No Measured Value Available - Error E041, E042, E043
28
Exchange Electronics Module
28
Maintenance
30
Description of Changing the Electronics Labels
30
Importing Short Cut Code into Crbasic Editor
31
Example Program
33
SDI-12 Commands/ Changing Settings
35
Query/Set the Address
36
Set Water Stage
37
Start False Echo Learn
37
Example of Setting Address
37
Example for Setting Water Stage
37
Set Units
38
Example of Setting and Getting Units
38
Set Water Conditions
39
Example for Setting and Getting Water Conditions
39
Set Power Operation Mode
40
Acknowledge Active Command
41
Example for Setting and Getting Power Operation Mode
41
Send Identification Command
42
Start Verification Command
42
Using Terminal Emulator and a Datalogger to Send Commands
43
SDI-12 Transparent Mode
44
CR200(X) Series Datalogger Example
44
CR1000 Datalogger Example
45
SDI-12 Transparent Mode on CR1000 Datalogger Using Control Port 1 and Changing SD1-12 Address from 3
45
FCC/IC Equipment Authorization (Usa/Canada Only
47
Advertisement
Campbell CS475 Instruction Manual (40 pages)
Radar Water Level Sensor
Brand:
Campbell
| Category:
Accessories
| Size: 0.84 MB
Table of Contents
Table of Contents
3
1 Overview
5
2 Specifications
6
CS475, CS476, and CS477
6
3 Installation
8
General Safety Instructions
8
Unpacking Equipment
8
Components and Hardware
8
Components and Hardware
9
Description of Components and Hardware Labels
9
Installation Recommendations
10
Site Selection
10
Sensor Mounting
11
Vertical Alignment
11
Azimuth Alignment
11
Radiation Beam Spread for CS475 (10° Beam Angle)
11
Radiation Beam Spread for CS476/CS477 (8° Beam Angle)
11
Instrument Housing Adjustment
12
Description of Polarization Markings Labels
12
4 Wiring
13
Datalogger Connection
13
Multiple Sensors Connection
13
Built-In Self Test (BIST)
13
Wiring Diagram
13
5 Configuration
14
Default Settings
14
Startup Procedure
14
Start False Echo Learn
14
Set Water Stage
15
Example of a Start False Echo Learn Command
15
6 Programming
16
Crbasic
16
Example for Setting Water Stage
16
Example Program
17
SDI-12 Command Codes
17
Edlog
18
Example Program
19
7 Diagnostics, Repair, and Maintenance
20
Testing Procedure
20
Start Measurement Command
20
Check Unit Response
21
Check for Valid Data
21
Example of Start Measurement Command
21
Acknowledge Active Command
21
Cyclic Redundancy Check (CRC)
22
Check CRC for Valid Data
22
Send Identification Command
22
Get Units
23
Get Water Conditions
23
Get Power Operation Mode
23
Checking CRC Example
23
Diagnostics and Repair
24
No Measured Value Available - Error E013
24
No Measured Value Available - Error E041, E042, E043
24
Exchange Electronics Module
24
Description of Changing the Electronics Labels
26
Maintenance
27
A-1. Description of Instrument Housing Labels
30
B-1. SDI-12 Commands
32
Changing Settings
33
Query/Set the Address
33
Set Units
33
B-2. SDI-12 Command for Querying the Address
33
B-3. Example of Setting Address
33
Set Water Conditions
34
Set Power Operation Mode
34
B-5. Example for Setting Water Conditions
34
B-6. Example for Setting Power Operation Mode
35
Advertisement
Related Products
Campbell CS476
Campbell CS440
Campbell CS477
Campbell CS475A
Campbell CS115
Campbell CS505
Campbell CS506
Campbell Scientific CS700H
Campbell CS250DM
Campbell CS241DM
Campbell Categories
Measuring Instruments
Accessories
Modem
Weather Station
Recording Equipment
More Campbell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL