Sign In
Upload
Manuals
Brands
Bruker Manuals
Laboratory Equipment
IFS 125M
Bruker IFS 125M Manuals
Manuals and User Guides for Bruker IFS 125M. We have
1
Bruker IFS 125M manual available for free PDF download: User Manual
Bruker IFS 125M User Manual (228 pages)
Brand:
Bruker
| Category:
Laboratory Equipment
| Size: 22 MB
Table of Contents
Table of Contents
3
1 Introduction
9
About this Manual
9
Terms
10
Safety
10
Warning Labels
10
Waste Disposal
12
General Information
12
Protective Earthing
12
Qualified Personnel
12
Intended Use
13
Questions and Concerns
13
2 General
15
Design
15
Optics
15
Electronics
15
Data Acquisition
16
3 Installation
17
Delivery Contents
17
Packaging
18
Transportation
18
Site Requirements
18
Connection Ports
20
Connecting Procedures
22
Connecting Cables to the Mobile Electronics Unit
22
Overview on Cables Connected
23
Connecting Spectrometer to Power Supply
24
Connecting Spectrometer to a PC
25
Connecting Accessories Via CAN Bus
26
Connecting Spectrometer to Purge Gas Supply Line
26
Inserting Beamsplitter
27
Handling Instructions
27
Inserting Procedure
28
4 Description
31
Spectrometer Front Side
31
Spectrometer Rear Side
32
Sample Compartment
33
Beamsplitter Lid
33
Beamsplitter Types
34
Detector Hoods
35
Detector Types
35
Scanner Compartment
37
Input Ports
38
Output Port
39
Mobile Electronics Unit
40
Panel Types
40
Optical Path
42
5 Operation
43
Operating Safety
43
Switching Spectrometer on and off
44
Spectrometer Operating Phase
45
Starting Spectroscopy Software
46
Setting up the Connection to the Optics
46
Inserting Accessory into Sample Compartment
47
Inserting Procedure
47
Checking the Signal
48
Procedure
48
Performing Measurement
50
Types of Measurement
50
Measurement Parameters
50
Measuring Procedure
51
Changing Beamsplitter
52
Handling Instructions
52
Changing Procedure
53
Cooling Detector
55
Safety Instructions When Working with Liquid Nitrogen
56
Cooling Procedure
57
Changing Detector
58
Changing Procedure
58
Purging the Spectrometer
65
6 Maintenance
67
General Maintenance Considerations
67
Electrostatic Discharge
68
Checking Laser Signal
68
Amplitude
68
Quick Check in OPUS
69
Signal Decrease over Optical Path
71
Readjusting Laser
73
Phase
76
Remounting Covers
77
Replacing Source
79
Source Types
79
Handling Instructions for Tungsten Source
80
Replacing Procedure
81
Replacing Window
82
Window Material
83
Replacing Procedure
85
Example of Window Assembly
85
Evacuating Detector
87
Evacuating Tools Required
88
Evacuating Procedure
89
Checking Drive Cable
92
Checking Procedure
93
Adjusting Procedure
94
Transporting Spectrometer
95
Removing Covers
95
Moving and Fixing Scanner
97
Removing Beamsplitter
99
Removing Optical Fiber Cable
100
Demounting Complete Scanning Arm
103
Fastening All Transport Locking Screws
105
Remounting Covers
106
Detaching All Cables
108
Re-Installation after Transport of Spectrometer
109
Removing Covers
109
Remounting Complete Scanning Arm
111
Re-Inserting Optical Fiber Cable
112
Connecting Cables
114
Inserting Beamsplitter
114
Checking Laser Signals
114
Checking Optical Alignment
115
Remounting Covers
118
Re-Adjusting Fiber-Coupling Head
120
Cleaning Housing
122
7 Troubleshooting
123
General Information on Fault Diagnostics
123
Remote Fault Diagnostics Via Full Report
124
Status Light in the OPUS Spectroscopy Software
125
Instrument Status Dialog in OPUS
126
Spectrometer Problems Indicated by Diagnostics Pages of Hardware Components
127
Spectrometer Problems Indicated by an Error Message in OPUS
128
Spectrometer Problems Indicated by File Parameters in OPUS
129
No Interferogram Observable in Check Signal Mode
130
Spectrometer Problems Indicated by Diagnostics Leds
133
Voltage Status Leds
133
ERR and SR Leds
135
No Data Transfer between Spectrometer and PC
137
RX LED Permanently off
137
Green RX LED on While Trying to Establish a Connection, but the Yellow TX LED off
138
8 Web Interface
139
Access Rights
139
User Authentication
140
Activating User Authentication
140
Deactivating User Authentication
142
Spectrometer Diagnostics
143
Direct Command Entry
145
Diagnostics
150
Service
158
Full Report
165
Direct Control Panel
169
9 Data Communication
171
Configuration Types
172
General Rules
172
Connecting Spectrometer to a Stand-Alone PC (Standard)
172
Connecting Spectrometer and PC to a Network
173
Connecting Spectrometer to Network PC
175
Network Addresses
176
Standard Configuration: Connecting Spectrometer to a Stand-Alone PC
176
Optional Configuration: Spectrometer and PC Connected to a Network
176
Optional Configuration: Spectrometer Connected to Network PC
177
Assigning Network Addresses
178
Communication between Spectrometer and PC
180
10 Connection Ports
181
Flange Panel
182
Electronics Connections and Leds
185
User Input/Output Signals (UIO Signals)
191
Pin Assignment
191
Timing
192
Power Supply Panel
194
A Specifications
197
Additional Information to the Resolution Specifications
200
Spare Parts
201
C Default Parameter Settings
203
D Dimensional Drawings
205
Firmware Update
209
Firmware Update on CD
209
Firmware Update Via E-Mail
209
Performing Firmware Update
210
Restoring a Previous Firmware Version
212
Backing up the Current Firmware Version
213
F Glossary
215
G Addresses
221
Index
223
Advertisement
Advertisement
Related Products
Bruker ImagePrep
Bruker ICON
Bruker MATRIX I
Bruker InsightMR
Bruker 300'154 Ascend DNP
Bruker 300'89 Ascend
Bruker 500'54 Ascend ULH
Bruker 500'89 Ascend Aeon
Bruker 600'54 Ascend ULH
Bruker 700'54 Ascend
Bruker Categories
Laboratory Equipment
Measuring Instruments
Industrial Equipment
Security Sensors
Amplifier
More Bruker Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL