Sign In
Upload
Manuals
Brands
Bilanciai Manuals
Power Supply
PS440 Series
Bilanciai PS440 Series Power Supply Unit Manuals
Manuals and User Guides for Bilanciai PS440 Series Power Supply Unit. We have
2
Bilanciai PS440 Series Power Supply Unit manuals available for free PDF download: Use And Maintenance Manual, Safety Instructions
Bilanciai PS440 Series Use And Maintenance Manual (110 pages)
and power supplier
Brand:
Bilanciai
| Category:
Touch terminals
| Size: 2 MB
Table of Contents
Table of Contents
3
1 General Matters
7
Declaration of Conformity
7
Foreword
7
Symbols
8
Documentation
9
ATEX Certification
10
Description of the Terminal
10
Versions
11
Options
11
Specifications of the Terminal
12
Terminal D440IS
12
Power Supplier Ps440/XXX
13
Power Supplier PS440-A/XXX
13
Dimensions and Weight of the Terminal
14
Obtaining Technical Assistance
17
Warranty
17
2 Safety Instructions
18
Prohibited Uses
18
Regulations
18
Recommendations for Installation
18
Classification of Zones and Substances
18
Compatibility
19
Surface or Underground
19
Categories of Equipment
19
Groups of Substances and Surface Temperatures
20
IP Protection Degree and Surface Temperature
20
Description of the System Installed
20
Prescriptions of Use
21
3 Document Describing the System
22
Foreword
22
Specifications of the Components Used
22
Ps440/XXX - PS440-A/XXX
22
D440Is
22
12X0.35 MM² Power Supplier-Terminal Connection Cable
23
6X0.5 MM² Cable for the Cells, Inputs/Outputs, Analogue Output
23
Optical Fibre
23
Sizing the System
24
Ps440/XXX D440IS Connection
24
Connection of the D440IS Scale - Load Cells Type Eurocell Is/XXX
24
Connection of D440IS - Clean Contact Inputs
24
Connection of Ps440/XXX Clean Contact Outputs Towards Safe Zone
24
Connection of PS440-Axxx - Output Exi
24
Connection of D440IS - 4-20Ma Analogue Output
24
Optical Fibre Connection
25
Global Protection Characteristics of the System
25
For Ambient Temperatures of up to +40°C
25
For Ambient Temperatures of up to +55°C
25
4 Delivery and Installation
26
Accesses
26
D440IS Accesses
26
Ps440/XXX Power Supplier Accesses
27
PS440-A/XXX Power Supplier Accesses
27
Connection of the Terminal to the Electrical Supply Line
28
Opening the Terminal for Access to the Internal Terminals
34
Internal Terminal Connections
37
Connection to the External Devices
38
Connection of the Terminal to the Platform Scale
39
Analogue Cell Connection
40
Output Connection
41
Input/Output Connection
43
How to Test the System
45
Verification of the Compatibility of the System
45
How to Check the Installation
46
How to Check the Documentation
47
5 Controls, Display, Switching the Terminal on and off
48
Display of Weight and Additional Information
48
Selection Display Symbols
50
Weighing Function Keys
51
Alphanumeric Keys
53
Switching the Terminal on and off
54
6 Using the Terminal
56
General Matters
56
Using the Keys to Navigate the Menus
56
Entering Numeric Data (Editor)
57
Entering Alphanumeric Data
57
Shortcut Keys
59
User Menu
60
Adjusting the Contrast
60
Changing the Date and Time
60
Weight Display
60
Memory Status
63
Reprint
63
Setting the Outputs as Setpoints (if Enabled)
63
Setting the Outputs as Ranges (if Enabled)
64
Generic Code
64
Product Code
65
Product Code List
66
Preset Tares
67
Preset Tare List
68
Progressive Number
69
Coefficient Management
69
Extraction Data
69
Totals Management
70
User Menu Access
71
Weighing Operation
71
Printing Weighing Data
72
Weighing Data Reprint
73
Automatic Print-Out
73
Operating Modes
74
Standard Operation
74
Loading Extraction Operation
74
Unloading Extraction Operation
75
Extraction on Loading with Fall Management
75
Operating Data
75
Extraction Totals
77
START Key
78
Data Displayed with Extraction Activated
79
Operating Principle of Extraction
80
Numeric Example of an Extraction Cycle
81
Error Messages
82
MPP Operation
82
Double Weighing Mode
83
Entrance and Exit Weighing
83
Entry/Exit Functions with Data Recall
84
Entry Weighing Procedures
84
Exit Weighing Procedures
86
Unused RCD Code Recovery
87
Entry/Exit Operations Using Licence Plate Data Recall
88
Preset Weight Options
89
How to Make the List of Preset Weights
89
Weighing Procedures with Preset Weights
90
Options for Entering the First Weight Manually
90
Total Management
91
7 Options
92
MPP Memory Expansion Boards
92
Memory Capacity
92
Operation
92
Disabling MPP
93
Checking Memorised Weight Data
94
Optical Fibre Output Option
94
Connection Harness
95
Point-To-Point Mode
96
Optic Loop Mode
96
Optical Fibre Adapter - RS232 (FO-232)
97
Printers
98
Connection with STB60 in the RS232 Mode
98
Connection to STB112 in RS232, -TM295, TMU295, LX300+, ITALORA
99
Connection to a PC
100
Ma Analogue Output
101
8 Maintenance
104
Lithium Battery
104
Casings
104
Test of the System
104
9 Troubleshooting
106
Malfunctions
106
Error Messages
107
Advertisement
Bilanciai PS440 Series Safety Instructions (14 pages)
for weighing terminals
Brand:
Bilanciai
| Category:
Power Supply
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Description
5
2 Mechanical Specifications
5
3 Electrical Specifications
6
4 Marking
7
Areas and Categories
7
5 Safety Instructions for Installation in Hazardous Areas
8
Wiring Diagram
9
Exe Connections
10
Exi Connections
10
Conductor Connections
10
Casing
11
Cable Glands
11
Application Example
11
6 Instructions for Disposing of Waste Electrical or Electronic Equipment
12
7 Example of Declaration of Conformity
13
Advertisement
Related Products
Bilanciai PS440-A Series
Bilanciai PTE LW
Bilanciai Cigiemme MERCURY PLUS AL500HBL/MX500HBL
Bilanciai PRM 80.60
Bilanciai PRM 100.100
Bilanciai PRM 125.125
Bilanciai PRM 150.125
Bilanciai PRM 150.150
Bilanciai PRM 200.125
Bilanciai PRM 200.150
Bilanciai Categories
Touch terminals
Scales
Measuring Instruments
Accessories
Industrial Equipment
More Bilanciai Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL