Alimentatore PS440-A/xxx per terminali di pesatura Istruzioni di sicurezza Power supplier PS440-A/xxx for weighing terminals Safety instructions Alimentation PS440-A/xxx pour indicateurs de pesage Consignes de sécurité Versorgungsgerät PS440-A/xxx für Wägeterminals Sicherheitsanweisungen Italiano English Français Deutsch 81320396 05/11/2018...
Foreword _____________________ Note _____________________ Document relating to CESI 05 ATEX 023 certificate. No changes are permitted without the approval of the Authorised Body _______________________________________________ 1. Description Power supplier PS440-A/xxx accepts various voltages on the input, as indicated in the following table: ...
4. Marking 0722 CESI YY ATEX nnn II 2(1) G Ex e mb [ia Ga] IIC T5, T4 Gb II 2(1) D Ex tb mb [ia Da] IIIC T100°C, T135°C Db Tamb (- 20°C ÷ + 40°C) T5/T100°C Tamb (- 20°C ÷ + 55°C) T4/T135°C 0722 number of the Notified Body for ATEX surveillance (CESI) CESI YY ATEX nnn...
5. Safety instructions for installation in hazardous areas Power supplier PS440/xxx (note 1) must be installed and serviced in compliance with the installation and maintenance instructions for sites classified against the risk of explosion, owing to the presence of gas and dust (example: EN 60079- 14, EN 60079-17 or other national norms/standards).
Wiring diagram Figure 1 Block diagram of the connections The terminal part of D440IS is not described in these Safety Notes. Please refer to the related documentation for more details.
5.1.1 Exe Connections Terminal N° Signal Description Line Power supply: line Ground Safety ground connection Neutral Power supply: neutral 5.1.2 Exi Connections Terminal N° Signal Description OUT1 Output 1 COM1 Common 1 OUT2 Output 2 COM2 Common 2 OUT3 Output 3 COM3 Common 3 GND_RELAY...
Casing The user must clean the casing regularly, to prevent a layer of dust from forming. Cable glands Insert the conductors into the cable glands and then tighten these latter. Unused cable glands must be closed with the supplied plugs. Application example D440 CELL 1…..4...
6. Instructions for disposing of waste electrical or electronic equipment This symbol on the weighing instrument you have purchased means that: this electric or electronic appliance cannot be disposed of as solid municipal waste; it must be collected separately; ...
7. Example of Declaration of Conformity EU SOCIETÀ COOPERATIVA BILANCIAI A.R.L. Via S. Ferrari, 16 41011 Campogalliano - MODENA Hereby declare under our responsibility, that products: PS440-A/230Vac: power supplier with 230 Vac input voltage, lot/SN: .. PS440-A/115Vac: power supplier with 115 Vac input voltage, lot/SN:..
Page 14
SOC. COOP. BILANCIAI CAMPOGALLIANO A.R.L. 41011 Campogalliano (MO) Via Ferrari, 16 tel. +39 (0) 59 893611 – fax +39 (0) 59 527079 home page: http://www.coopbilanciai.it E-mail: cb@coopbilanciai.it servizio post-vendita after sales service service apres-vente Kundendienstservice servicio post-venta serviço pós-venda tel. +39 (0) 59 893612 – fax +39 (0) 59 527294...