Bilanciai PS440-A Series Safety Instructions
Bilanciai PS440-A Series Safety Instructions

Bilanciai PS440-A Series Safety Instructions

For weighing terminals
Hide thumbs Also See for PS440-A Series:

Advertisement

Quick Links

Alimentatore PS440-A/xxx per terminali di pesatura
Istruzioni di sicurezza
Power supplier PS440-A/xxx for weighing terminals
Safety instructions
Alimentation PS440-A/xxx pour indicateurs de pesage
Consignes de sécurité
Versorgungsgerät PS440-A/xxx für Wägeterminals
Sicherheitsanweisungen
Italiano
English
Français
Deutsch
81320396
05/11/2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS440-A Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bilanciai PS440-A Series

  • Page 1 Alimentatore PS440-A/xxx per terminali di pesatura Istruzioni di sicurezza Power supplier PS440-A/xxx for weighing terminals Safety instructions Alimentation PS440-A/xxx pour indicateurs de pesage Consignes de sécurité Versorgungsgerät PS440-A/xxx für Wägeterminals Sicherheitsanweisungen Italiano English Français Deutsch 81320396 05/11/2018...
  • Page 3: Table Of Contents

    _____________________________PS440-A/xxx__ Table of Contents 1. Description ........................... 3 2. Mechanical specifications ....................3 3. Electrical specifications ...................... 4 4. Marking ..........................5 ..................5 REAS AND CATEGORIES 5. Safety instructions for installation in hazardous areas ............ 6 ....................7 IRING DIAGRAM 5.1.1 Exe Connections ..................
  • Page 5: Description

    Foreword _____________________ Note _____________________ Document relating to CESI 05 ATEX 023 certificate. No changes are permitted without the approval of the Authorised Body _______________________________________________ 1. Description Power supplier PS440-A/xxx accepts various voltages on the input, as indicated in the following table: ...
  • Page 6: Electrical Specifications

    3. Electrical specifications Mains power supply Pn=20VA Um=250V L (line), N(neutral), T(ground) Fn=50/60Hz PS440/230Vac Un =230Vac PS440/115Vac Un =115Vac PS440/24Vac Un =24Vac Outputs (clean contacts) =125Vac/dc Out1 terminals 1-2 =200mA Out2 terminals 3-4 Out3 terminals 5-6 Out4 terminals 1-2 Display power supply Uo =12.24V Co ...
  • Page 7: Marking

    4. Marking 0722 CESI YY ATEX nnn II 2(1) G Ex e mb [ia Ga] IIC T5, T4 Gb II 2(1) D Ex tb mb [ia Da] IIIC T100°C, T135°C Db Tamb (- 20°C ÷ + 40°C) T5/T100°C Tamb (- 20°C ÷ + 55°C) T4/T135°C 0722 number of the Notified Body for ATEX surveillance (CESI) CESI YY ATEX nnn...
  • Page 8: Safety Instructions For Installation In Hazardous Areas

    5. Safety instructions for installation in hazardous areas Power supplier PS440/xxx (note 1) must be installed and serviced in compliance with the installation and maintenance instructions for sites classified against the risk of explosion, owing to the presence of gas and dust (example: EN 60079- 14, EN 60079-17 or other national norms/standards).
  • Page 9: Wiring Diagram

    Wiring diagram Figure 1 Block diagram of the connections The terminal part of D440IS is not described in these Safety Notes. Please refer to the related documentation for more details.
  • Page 10: Exe Connections

    5.1.1 Exe Connections Terminal N° Signal Description Line Power supply: line Ground Safety ground connection Neutral Power supply: neutral 5.1.2 Exi Connections Terminal N° Signal Description OUT1 Output 1 COM1 Common 1 OUT2 Output 2 COM2 Common 2 OUT3 Output 3 COM3 Common 3 GND_RELAY...
  • Page 11: Casing

    Casing The user must clean the casing regularly, to prevent a layer of dust from forming. Cable glands Insert the conductors into the cable glands and then tighten these latter. Unused cable glands must be closed with the supplied plugs. Application example D440 CELL 1…..4...
  • Page 12: Instructions For Disposing Of Waste Electrical Or Electronic Equipment

    6. Instructions for disposing of waste electrical or electronic equipment This symbol on the weighing instrument you have purchased means that:  this electric or electronic appliance cannot be disposed of as solid municipal waste;  it must be collected separately; ...
  • Page 13: Example Of Declaration Of Conformity

    7. Example of Declaration of Conformity EU SOCIETÀ COOPERATIVA BILANCIAI A.R.L. Via S. Ferrari, 16 41011 Campogalliano - MODENA Hereby declare under our responsibility, that products:  PS440-A/230Vac: power supplier with 230 Vac input voltage, lot/SN: .. PS440-A/115Vac: power supplier with 115 Vac input voltage, lot/SN:..
  • Page 14 SOC. COOP. BILANCIAI CAMPOGALLIANO A.R.L. 41011 Campogalliano (MO) Via Ferrari, 16 tel. +39 (0) 59 893611 – fax +39 (0) 59 527079 home page: http://www.coopbilanciai.it E-mail: cb@coopbilanciai.it servizio post-vendita after sales service service apres-vente Kundendienstservice servicio post-venta serviço pós-venda tel. +39 (0) 59 893612 – fax +39 (0) 59 527294...