Sign In
Upload
Manuals
Brands
Bender Manuals
Measuring Instruments
COM465IP
Bender COM465IP Manuals
Manuals and User Guides for Bender COM465IP. We have
4
Bender COM465IP manuals available for free PDF download: Manual, Quick Start Manual, Quick Start
Bender COM465IP Manual (68 pages)
Condition Monitor with integrated Gateway for the connection to PROFIBUS DP and Ethernet-TCP/IP networks
Brand:
Bender
| Category:
Measuring Instruments
| Size: 2.15 MB
Table of Contents
Table of Contents
3
1 Important Information
7
How to Use this Manual
7
Technical Support: Service and Support
8
First Level Support
8
Repair Service
8
Field Service
9
Training Courses
9
Delivery Conditions
9
Inspection, Transport and Storage
10
Warranty and Liability
10
Disposal
10
2 Safety Instructions
11
General Safety Instructions
11
Work on Electrical Installations
11
Intended Use
11
Address Configuration and Termination
12
3 Product Description
13
Scope of Delivery
13
Device Features
13
Functional Scope of COM465IP and COM465DP Basic Device (Without Function Modules)
13
Function Module a
14
Function Module B
14
Function Module C
15
Function Module D
15
Function Module E
15
Function Module F
15
Applications
15
Function
16
Software Products Used
16
Description of Function
17
Interfaces
17
Process Image
18
List of BMS Devices Compatible with the COM465
18
BMS Side of the COM465
18
4 Installation, Connection and Commissioning
19
Preliminary Considerations
19
Installation and Connection
20
Installing Device
20
Outline Drawing
20
Connecting Device
21
Displays and Controls
22
Com465
22
Placing Device in Operation
23
Addresses and Their Factory Settings
24
Installing GSD File for PROFIBUS DP Master (COM465DP Only)
24
5 PROFIBUS DP (COM465DP Only)
25
PROFIBUS DP Side of the COMTRAXX® COM465DP
25
Cyclic Data Exchange
25
Correct Control of the Timing on the COM465DP Using PROFIBUS Commands Is Necessary
26
The COM465DP Communicates as "BMS Master" with the PROFIBUS DP Master
26
Formats of the Output and Input Data
26
Data Access Using PROFIBUS DP
27
Type 1: Querying Measured Data from Devices on the Bus
27
Type 2: Querying Registers in Devices on the Bus
28
Type 3: Writing to Registers on Devices on the Bus
29
Programming Examples
31
Type 1: Querying Measured Data from Devices on the Bus
31
Example 1: Querying Measured Value from the RCMS490-D
31
Example 2: Querying Measured Value in the Event of an IRDH375 Alarm
33
Example 3: Querying IRDH375 Device Fault
35
Type 2: Querying Registers in Devices on the Bus
37
Example: Querying a Register on the RCMS490-D
37
Type 3: Writing to Registers on Devices on the Bus
38
Example: Writing to a Register on the RCMS490-D
38
6 Modbus TCP Server
39
Data Access Using Modbus TCP Protocol
39
Exception Code
39
Modbus Requests
39
Modbus Responses
40
Structure of the Exception Code
40
Modbus Address Structure for BMS Devices
40
Modbus Process Image in the Memory of the COM465
41
Querying Data
41
Modbus Function Code FC03
41
Modbus Function Code FC04
41
How Are the Memory Areas Organised
41
Memory Scheme of the Process Image
42
Structure of the Process Image
42
Memory Scheme of an Individual Device
42
Device Type
44
Timestamp
44
C = Common Alarm and D = Device Lost (Device Failure)
44
Channels 1 to 32 with Analogue And/Or Digital Values
44
Float = Floating Point Value of the Channels
45
A&T = Alarm Type and Test Type (Internal/External)
45
R&U = Range and Unit
46
Channel Description
47
Channel 33 to 64
48
Modbus Examples to Read out Data
49
Reference Data Records of the Process Image
50
Address Assignment of the Reference Data Record
50
Reference Value on Channel 1
50
Reference Value on Channel 2
51
Explanation of How to Access Floating Point Values
51
Channel Descriptions for the Process Image
52
Modbus Control Commands
56
Modbus Example for Control Commands
58
7 Troubleshooting
59
Malfunctions
59
What Should be Checked
59
Frequently Asked Questions
59
Maintenance
60
Cleaning
60
8 Technical Specifications
61
Tabular Data
61
Standards, Approvals and Certificates
63
Ordering Data
64
Index
65
Advertisement
Bender COM465IP Manual (64 pages)
Condition Monitor with integrated Gateway
Brand:
Bender
| Category:
Gateway
| Size: 1.93 MB
Table of Contents
Table of Contents
3
1 Making Effective Use of this Documentation
7
How to Use this Manual
7
Terms Used
8
Explanations of Symbols and Notes
8
2 Safety Instructions
9
Work on Electrical Installations
9
Intended Use
9
Address Configuration and Termination
9
Delivery Conditions, Guarantee, Warranty and Liability
10
3 Product Description
11
Scope of Delivery
11
Device Features
11
Function Scope of COM465IP and COM465DP Basic Device (Without Function Modules)
11
Function Module a
12
Function Module B
12
Function Module C
13
Function Module D
13
Applications
13
Function
14
Software Products Used
14
Description of Function
15
Interfaces
15
Process Image
16
List of BMS Devices Compatible with the COM465
16
BMS Side of the COM465
16
4 Installation, Connection and Commissioning
17
Preliminary Considerations
17
Installation and Connection
18
Installing the Device
18
Dimensions Diagram
18
Connecting the Device
19
Display and Operating Elements
20
Com465
20
Commissioning of the Device
20
Addresses and Their Factory Settings
21
Installing GSD File for PROFIBUS DP Master (COM465DP Only)
22
5 PROFIBUS DP (COM465DP Only)
23
PROFIBUS DP Side of the COMTRAXX® COM465DP
23
Cyclic Data Exchange
23
Correct Control of the Timing on the COM465DP Using PROFIBUS Commands Is Necessary
24
COM465DP Communicates as "BMS Master" with the PROFIBUS DP Master
24
Formats of the Output and Input Data
24
Data Access Using PROFIBUS DP
25
Type 1: Requesting Measured Data from Devices on the Bus
25
Type 2: Requesting Registers in Devices on the Bus
26
Type 3: Writing to Registers in Devices on the Bus
27
Programming Examples
29
Type 1: Requesting Measured Data from Devices on the Bus
29
Example
29
Requesting Measured Value from the RCMS490-D
29
Example
31
Requesting Measured Value in the Event of an IRDH375 Alarm
31
Example 3: Requesting IRDH375 Device Fault
33
Type 2: Requesting Registers in Devices on the Bus
35
Example: Requesting a Register on the RCMS490-D
35
Type 3: Writing to Registers in Devices on the Bus
36
Example: Writing to a Register on the RCMS490-D
36
6 Modbus TCP Server
37
Data Access Using Modbus TCP Protocol
37
Exception Code
37
Modbus Requests
37
Modbus Responses
38
Structure of the Exception Code
38
Modbus Address Structure for BMS Devices
38
Modbus Process Image in the Memory of the COM465
39
Requesting Data
39
Modbus Function Code
39
How Are the Memory Areas Organised
39
Memory Scheme of the Process Image
40
BMS Device Address Assignment on the Modbus
40
Memory Scheme of an Individual BMS Device
40
Device Type
42
Time Stamp
42
C = Common Alarm and D = Device Lost (Device Failure)
42
Channels 1 to 32 with Analogue And/Or Digital Values
42
Floating Point Value of the BMS Channels
43
A&T = Alarm Type and Test Type (Internal/External)
43
R&U = Range and Unit
44
Channel Description
45
Channel 33 to 64
46
Reference Data Records of the Process Image
47
Address Assignment of the Reference Data Record
47
Reference Value on Channel 1
47
Reference Value on Channel 2
48
Explanation of How to Access Floating Point Values
48
Channel Descriptions for the Process Image
49
Modbus Control Commands
54
7 Troubleshooting
57
Damage in Transit
57
Malfunctions
57
What Should be Checked
57
Frequently Asked Questions
57
Where Do You Get Help
58
Maintenance
58
Cleaning
58
Disposal
58
8 Technical Data
59
Tabular Data
59
Ordering Information
62
Standards, Approvals and Certificates
62
Index
63
Bender COM465IP Quick Start Manual (8 pages)
Condition Monitor with integrated Gateway
Brand:
Bender
| Category:
Gateway
| Size: 1.34 MB
Table of Contents
Gerät Anschließen
4
Connecting the Device
4
Wiring Diagram
5
Gerät in Betrieb Nehmen
6
Commissioning the Device
6
Factory Settings
7
Technische Daten
7
Technical Data
7
Advertisement
Bender COM465IP Quick Start (4 pages)
Condition Monitor with integrated gateway system/Ethernet TCP/IP
Brand:
Bender
| Category:
Measuring Instruments
| Size: 2.02 MB
Advertisement
Related Products
Bender COMTRAXX COM465ID
Bender COMTRAXX COM465DP
Bender COMTRAXX COM465DP-230V
Bender COMTRAXX COM465DP-24V
Bender COMTRAXX COM465IP-230V
Bender COMTRAXX COM465IP-24V
Bender CMD421
Bender CMD420
Bender LANTRAXX CMS460-D
Bender CMD420-DM
Bender Categories
Measuring Instruments
Monitor
Control Unit
Control Panel
Relays
More Bender Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL