Sign In
Upload
Manuals
Brands
BEAMEX Manuals
Measuring Instruments
MC6-T
BEAMEX MC6-T Manuals
Manuals and User Guides for BEAMEX MC6-T. We have
4
BEAMEX MC6-T manuals available for free PDF download: Manual, Quick Reference Manual, Quick Start Manual
BEAMEX MC6 Series, MC6-Ex, MC6-WS, MC6-T Manual
Brand:
BEAMEX
| Category:
Control Unit
| Size: 0 MB
Table of Contents
Introduction
Requirements
Enable communication between an MC6 family calibrator and a Client device
Information window
Troubleshooting
Safety and connection security
CONTACTS
Documents / Resources
References
Advertisement
BEAMEX MC6-T Manual (172 pages)
Multifunction Temperature Calibrator and Communicator
Brand:
BEAMEX
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
3
Prologue
7
About this Manual
8
Where am I
8
Typographical Conventions
9
Unpacking and Inspection
9
Feedback
10
MC6-T Safety
11
Approvals
11
Symbols Used
11
Operating Environment
11
Safety Precautions and Warnings
13
Warnings Concerning Temperature
14
Using the Temperature Block
14
After Using the Temperature Block
15
Warnings Concerning Electrical Measurement and Generation
16
Warnings Concerning Pressure
16
General Warnings Concerning Pressure Measurement
16
Warnings Concerning High Pressure
17
General Description
19
About MC6-T
19
Hardware
19
General
19
MC6-T Top View
21
Connectors on the Left Side of MC6-T
22
MC6-T Handle
22
Memory
23
Display
23
Batteries
23
Power Management
24
User Interface
28
PC Communication/Calibration Software
32
USB Communication Driver
32
MC6-T Related Tools Available for Personal Computer
32
Options
33
Software Options
33
Hardware Modules/Options and Accessories
34
Accessory Holder Kit
34
Related Products
37
Active Terminals and Connections
39
General
39
Measurements
40
Temperature Measurement (Thermocouple)
40
Temperature Measurement (RTD)
41
Resistance Measurement
42
Pressure Measurement
43
Connecting and Disconnecting External Pressure Modules
43
Zeroing a Pressure Module
44
Current Measurement
44
Voltage Measurement
45
Frequency Measurement
45
Pulse Counting
46
Switch Sensing
47
Generations/Simulations
47
Changing the Generated/Simulated Value
47
Using the Soft Numeric Keypad
47
Spinning
48
Temperature Generation
49
Inserts to be Used in the Temperature Block
50
Thermocouple Simulation
51
RTD Sensor Simulation
52
Current Generation (Source or Sink)
53
Voltage Generation
54
Resistance Simulation
54
Frequency Generation
55
Pulse Generation
56
Thermocouple Connections
57
Tools
59
Tools for Measurements
60
Additional Stability Check
62
Tools for Generations/Simulations
64
Temperature Calibrator
67
About Temperature Calibrator
67
The Menu
70
Calibrator
71
About Calibrator
71
Documenting Calibrator
73
General
73
Calibration Software
74
Calibrating Instruments
74
Generating/Simulating the Input Value
75
Instrument List
75
Instruments
76
Instrument List Window Menu
87
Plant Structure Levels
88
Work Order View Mode
88
Instrument Overview Window
90
Calibrating an Instrument Using MC6-T
91
Changing the Pressure Module During Calibration
95
About Fieldbus and HART Device Specifics
96
Calibration Results
97
Deleting Calibration Results
98
Get Mapped Value Feature
98
Getting and Editing Mapped Data
99
Preparations
99
Getting Default Mappings
100
Customizing the Mappings
100
Mobile Security Plus Software Option
103
General
103
Applied Restrictions
103
Data Logger
105
General
105
Doing a Data Log
106
Configuring
106
Saving and Opening Configurations
109
Starting the Data Log
110
Viewing and Saving or Deleting the Results
111
Viewing Saved Data Log Results
112
Transferring Data Log Results to a Personal Computer
113
Communicator
115
General
115
Warnings
118
Connections
118
Selecting the Instrument
120
List of Found Devices
121
About Instrument Parameters
122
Instrument Parameters in General
122
Calibrating or Data Logging HART Instruments
123
Calibrating or Data Logging Fieldbus Instruments
124
Editing Parameters
125
Trimming a HART Instrument
126
Trimming a Fieldbus Instrument
129
HART Device Description Specifics
131
About HART Device Description
131
Basic View
132
Managing Digital Communication Instrument Configurations
134
General
134
Tools in MC6-T
135
Saving Configurations
135
Viewing/Managing Configurations
135
Beamex MC6 Fieldbus Configuration Viewer
136
Uploading Configurations
137
Linking Configurations to CMX
137
Settings
139
Settings Overview
139
Maintenance
141
Replacing the Mains Fuses
141
Overtemperature Protection Test Mode
142
Cleaning Instructions
143
Firmware Update
144
Recalibrating MC6-T
144
Disposal of Waste Electrical and Electronic Equipment
145
Beamex and WEEE
145
Service and Transportation Instructions
147
Safe Delivery for Service
147
Resetting MC6-T
149
Additional Information
151
User Defined Function Data
151
User Defined PRT/RTD Sensors
152
General
152
Callendar Van Dusen Formula for Prts
154
ITS-90 PRT Sensor
155
Factor
157
Check Sensor Conversion
158
User Defined Transfer Functions
159
User Defined Pressure Units
161
User Defined Steps Calibration Points
163
Controller Communication
164
What Can be Done with Controller Communication
165
Configuring Controller Communication
166
Changing Controller During Calibration
167
Index
169
BEAMEX MC6-T Quick Reference Manual (12 pages)
Wireless Communication
Brand:
BEAMEX
| Category:
Test Equipment
| Size: 0 MB
Table of Contents
Table of Contents
2
Introduction
3
Safety and Connection Security
4
Requirements
5
Enable Communication between an MC6 Family Calibrator and a Client Device
6
Information Window
9
Troubleshooting
11
Advertisement
BEAMEX MC6-T Quick Reference Manual (13 pages)
Brand:
BEAMEX
| Category:
Test Equipment
| Size: 0 MB
Advertisement
Related Products
BEAMEX MB140
BEAMEX MB155
BEAMEX MB425
BEAMEX MB700
Beamex MC6
BEAMEX MC6-Ex
BEAMEX MC6-WS
BEAMEX MC5-IS
BEAMEX MC5
BEAMEX MCS200
BEAMEX Categories
Test Equipment
Water Pump
Measuring Instruments
Control Unit
Controller
More BEAMEX Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL