Sign In
Upload
Manuals
Brands
BEAMEX Manuals
Test Equipment
MC5P
BEAMEX MC5P Manuals
Manuals and User Guides for BEAMEX MC5P. We have
1
BEAMEX MC5P manual available for free PDF download: User Manual
BEAMEX MC5P User Manual (166 pages)
MULTIFUNCTION CALIBRATOR
Brand:
BEAMEX
| Category:
Test Equipment
| Size: 3.24 MB
Table of Contents
Table of Contents
3
Introduction
10
About this Manual
10
Typographical Conventions
11
Unpacking and Inspection
11
MC5P Hardware
12
Operational Sections and Connections
12
Base Unit and the Display
13
Electrical Module (E Module)
13
Electrical and Temperature Module (et Module)
14
Reference Junction Module
14
Internal Pressure Modules
15
External Pressure Modules
15
Environment Temperature Interface
15
Computer/Printer Interface
16
Auxiliary Instrument Interface
16
Keyboard
17
Memory
18
Power Supply
18
MC5P Firmware
19
General Description
19
Startup Procedure
19
Basic Mode
20
Maintenance
20
Calibration Mode
20
Help Function
21
Printing
21
The Status Bar
22
The User Interface
22
The Function Key Bar
23
Menus
23
The Display Area
24
Mc5P's Modularity and Options
28
Hardware Modules/Options
28
Other Connectable Devices
29
Firmware Options
29
Safety
30
Certifications and Compliances (EC Declaration of Conformity)
30
Safety Precautions and Warnings
31
General Warnings
31
General Warnings Concerning Pressure Measurement
32
Warnings Concerning the Use of Electrical Modules (E and ET)
32
Warnings Concerning High Pressure
33
Service
34
Firmware Update
34
Recalibrating MC5P
34
The Battery Charger
34
Cleaning MC5P
35
Cleaning the Contacts of the Internal Reference Junction Module
35
Part B, Startup and Basic Operation
37
Starting MC5P
38
Startup Procedure
38
Basic Mode, Defined
39
Measuring
41
Using External Modules
43
Pressure Measurement
43
Using Internal Modules
43
Zeroing a Pressure Module
44
Current Measurement
45
External Supply
45
Internal Supply
45
Voltage Measurement
46
Measuring Low Voltages
46
Measuring Voltages up to ±50 V
47
Resistance Measurement
48
Switch State Sensing
49
Limit Switch Test
50
Performing the Limit Switch Test
50
Frequency Measurement
52
Pulse Counting
53
RTD Measurement (Temperature)
54
Thermocouple Measurement (Temperature)
55
Internal Reference Junction
55
External Reference Junction
55
Special Measurements
57
Mathematical Special Measurements
58
Minimum Value
58
Maximum Value
58
Min/Max Value
58
Rate of Change
58
Special Filtering and Resolution
59
Deviation Measurement
59
Special Measurements Using Two Ports Simultaneously
60
Difference Measurement
60
Redundant Measurement
61
Generating/Simulating
62
General
62
Changing the Value of the Generated/Simulated Signal
63
Current Generation
64
Using the et Module's Output Terminals
64
Using the E Module's Output Terminals
64
Voltage Generation
66
Generating Voltages up to ±12 V
66
Low Voltage Generation
66
Frequency Generation
68
Pulse Generation
69
RTD and Resistance Simulation
70
Thermocouple Simulation
71
Internal Reference Junction
71
External Reference Junction
71
Special Generations
73
Opening the Step or Ramp Configuration Window
73
Stepping
74
Ramping
75
Alarm Limit Settings
77
Part C, Advanced Operation and Configurations
79
Configuring the Calibrator
80
Settings
80
Setting Time and Date
82
Measuring the Environment Temperature with the ENV Sensor
83
Advanced Utilities
83
Display Mode Settings
84
Scaling
85
Displaying Values in Percentage
86
Displaying Error Values
86
Transmitter/Switch Simulation
87
Transmitter Simulation
88
Switch Simulation
89
Data Logging
90
General
90
Configuring
90
Starting the Data Log
91
Transferring the Results to a Personal Computer
92
Viewing the Results
92
Generating Signals Using External Devices
93
Controlling the External Device in Basic Mode
94
Pressure Controller Settings
95
Temperature Controller Settings
96
Printing
97
Additional Information
98
Things to Consider When Measuring Pressure
99
General
99
Pressure Type
99
Pressure Modules and Their Naming Conventions
100
Square Rooting
100
Thermocouple Measurement/Simulation, Connections and Troubleshooting
101
Internal Reference Junction
101
External Reference Junction
102
Error Situations
104
Resistance and RTD Measurement, Connections
105
4-Wire System
105
Using a Compensation Loop
106
2-Wire System
106
Current Measurement Parallel to a Test Diode, Connections
107
Parallel Functions in MC5P
108
Part D, Calibration
109
General
110
Phases of Instrument Calibration
111
As Found Calibration
112
Adjustment
112
As Left Calibration
113
Required Modules for Different Input/Output Signal Combinations
114
Calibrating an Instrument
116
Selecting the Instrument to be Calibrated
116
The Instrument Window
117
A Calibration Procedure Using MC5P
118
About Automatic Calibration
120
About Manual Calibration
120
Autocapture Feature
121
Examples of Instrument Calibration
121
Pressure Transmitters and Sensors
122
Temperature Sensors
124
Temperature Indicators and Recorders
126
Electrical Limit Switches
128
Using External Devices in Calibration Mode
130
Mc5P's Support for Instrument Adjustment
131
Maintaining Mc5P's Instrument Database
132
Adding New Instruments
132
Editing Instrument Data
133
General Data Page
133
Instrument Input Page
134
Instrument Output Page
135
Calibration Settings Page
135
Calibration Instructions Page
136
Deleting Instruments
136
Viewing Calibration Results
137
Calibration Result Windows
138
How to Choose Which Calibration Run Is Viewed
138
Deleting Calibration Results
138
Appendixes
140
General
141
HART Instruments and Beamex's Calibration Database Software
141
MC5P and HART
141
Connecting MC5P and a HART Instrument
142
External Supply
142
Supply from the Calibrator
142
Test Diode Connections
143
Using MC5P as a HART Communicator
143
HART Communication Settings
144
Connecting to a HART Instrument
145
HART and Mc5P's Basic Mode
145
Device Information
146
Disconnecting a HART Instrument
146
Device Settings
147
Trimming a HART Instrument in Basic Mode
147
Adding a HART Instrument to Mc5P's Instrument Database
149
Calibrating a HART Instrument
150
Selecting the Instrument to be Calibrated
150
The Calibration Procedure
151
Trimming a HART Instrument in Calibration Mode
151
MC5P General Specifications
155
Modules
156
Pressure Modules (INT & EXT)
156
RTD Measurement and Simulation
157
Temperature Electrical Module (ET)
157
Reference Junction Module (RJ)
158
Thermocouple Measurement and Simulation
158
Electrical Module (E)
159
Appendix 3, Quick Guide for the Mc5 Datalog Viewer
160
Communication Settings
161
File Management
161
General
161
Installing MC5 Datalog Viewer
161
MC5 Datalog Viewer
161
Transferring Data from MC5P
161
Chart Properties
162
Importing and Exporting
162
Opening Existing Data Files
162
Other Utilities
162
Saving Data on Hard Disk
162
Channel Properties
163
Printing the Graph
163
Zooming
163
Advertisement
Advertisement
Related Products
BEAMEX MC4
BEAMEX MC5-IS
BEAMEX MC5
BEAMEX MC6-Ex
BEAMEX MC6-WS
BEAMEX MCS100
BEAMEX MC5-IS-FF
BEAMEX MC2-IS
BEAMEX MC6-T
BEAMEX MCS200
BEAMEX Categories
Test Equipment
Water Pump
Measuring Instruments
Controller
Desktop
More BEAMEX Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL