Sign In
Upload
Manuals
Brands
BD Manuals
Measuring Instruments
LSR II
BD LSR II Benchtop Flow Cytometer Manuals
Manuals and User Guides for BD LSR II Benchtop Flow Cytometer. We have
4
BD LSR II Benchtop Flow Cytometer manuals available for free PDF download: User Manual, Workbook
BD LSR II User Manual (204 pages)
flow cytometer
Brand:
BD
| Category:
Laboratory Equipment
| Size: 7 MB
Table of Contents
Table of Contents
5
About this Guide
11
Conventions
11
BD LSR II Documentation
12
BD LSR II Online Help
12
Printed Documentation
13
Electronic Documentation
14
Technical Assistance
15
Safety and Limitations
17
Laser Safety
17
Laser Product Classification
18
Precautions for Safe Operation
18
Electrical Safety
19
Biological Safety
20
General Safety
21
Symbols and Labels
21
Limitations
23
Chapter 1: Introduction
25
Overview
26
Components
26
Power Switch
26
Control Panel
27
Handles
27
Fluidics
28
Sample Flow Rate Control
28
Fluid Control
28
Sample Injection Port
29
Sheath and Waste Containers
31
Optics
32
Lasers
33
Filters
34
Detectors
35
BD LSR II Workstation
36
Chapter 2: Instrument Setup
37
Starting the Cytometer and Computer
38
Setting up the Optical Filters and Mirrors
39
Filter and Mirror Configurations
40
Changing Optical Filters or Mirrors
42
Filter and Mirror Specifications
43
Preparing Sheath and Waste Containers
44
Preparing the Sheath Container
44
Preparing the Waste Container
46
Preparing the Fluidics
47
Removing Air Bubbles
47
Priming the Fluidics
49
Quality Control
49
Chapter 3: Running Samples
51
Sample Optimization Using Instrument Setup
52
Verifying Instrument Configuration and User Preferences
54
Creating an Experiment
56
Adjusting the Voltages and Threshold
59
Calculating Compensation
63
Recording and Analyzing Data
65
Preparing the Workspace
65
Recording Data
67
Analyzing Data
69
Reusing the Analysis
73
Saving the Analysis
73
Chapter 4: DNA Analysis
75
Criteria for DNA Experiments
76
DNA Setup
77
How to Use DAPI with DNA QC
77
How to Use PI with DNA QC
78
CEN Optimization
78
Preparing the Workspace
78
Running CEN
82
CTN Resolution
84
Running CTN
84
Optimization for Data Recording
86
Chapter 5: Calcium Flux
87
Intracellular Calcium Concentration
88
Calcium Flux Optimization
89
Using the Time Parameter
89
Setting up the Experiment
90
Optimizing for Calcium Flux
94
Recording Calcium Flux Data
96
Chapter 6: Maintenance
99
Daily Cleaning and Shutdown
100
Daily Fluidics Cleaning
100
Daily Shutdown
102
Scheduled Maintenance
103
System Flush
103
Waste Management System Maintenance
105
Periodic Maintenance
107
Changing the Sheath Filter
108
Changing the Bal Seal
110
Changing the Sample Tube O-Ring
112
Chapter 7: Troubleshooting
113
Instrument Troubleshooting
114
Appendix A: Technical Overview
123
Fluidics
124
Optics
125
Light Scatter
125
Fluorescence
126
Optical Filters
127
Compensation Theory
131
Electronics
134
Pulse Measurements
135
Digital Electronics
136
BD Facsdiva Option White Paper
136
Threshold
137
Laser Controls
137
Appendix B: BD LSR II QC Log
139
Appendix C: Filter Templates
143
Octagon Template
145
Trigon Template
147
Appendix D: Supplies and Consumables
149
QC Particles
150
Reagents
151
Equipment
152
Appendix E: Standard Default Configuration
153
Standard (4-Blue 2-Violet 2-UV 2-Red) Configuration Specification
154
Default Configuration
155
Octagon and Trigon Maps
156
Custom Configurations
159
Appendix F: Special Order Configurations
165
Common Special Order Configurations
166
6-Blue 0-Violet 0-UV 3-Red Configuration
167
6-Blue 2-Violet 0-UV 3-Red Configuration
168
6-Blue 0-Violet 2-UV 3-Red Configuration
169
6-Blue 2-Violet 2-UV 3-Red Configuration
171
6-Blue 6-Violet 0-UV 3-Red Configuration
172
6-Blue 6-Violet 0-UV 4-Red Configuration
174
6-Blue 6-Violet 2-UV 3-Red Configuration
176
6-Blue 6-Violet 2-UV 4-Red Configuration
178
Special Order Configuration Trigon and Octagon Maps
180
6-Color Blue Octagon Default Configuration Map
181
2-Color Violet Trigon Default Configuration Map
182
6-Color Violet Octagon Default Configuration Map
183
2-Color UV Trigon Default Configuration Map
184
3-Color Red Trigon Default Configuration Map
185
4-Color Red Octagon Default Configuration Map
186
BD FACS Instrument Configuration Application
187
Installing ICA
187
Updating Your Default Configuration
188
Appendix G: Setting Laser Delay
193
About Laser Delay
194
Optimizing Laser Delay
195
Advertisement
BD LSR II User Manual (184 pages)
High Throughput Sampler
Brand:
BD
| Category:
Laboratory Equipment
| Size: 6 MB
Table of Contents
Table of Contents
5
About this Guide
9
Conventions
10
Technical Assistance
11
Chapter 1: Introduction
13
HTS Hardware Overview
14
Components
16
Cytometer Connections
19
Cytometer Interface Panel
19
Sample Coupler
21
Sample Processing
23
Chapter 2: BD Facsdiva Software Overview
27
Workspace Components
28
Plate Window
32
Setup View Components
33
Setup View Functions
43
Analysis View Components
48
Analysis View Functions
51
Chapter 3: Running Samples
55
Starting up
56
Setting up for Plate-Based Acquisition
59
Creating Experiments
64
Creating a Folder and an Experiment
64
Setting up the Plate
67
Setting up the Worksheet
74
Exporting a Plate as a Template
76
Assigning Keywords
77
Preparing for Acquisition
78
Optimizing Cytometer and HTS Settings
78
Performing Compensation
81
Acquiring Data
82
Pausing the BD High Throughput Sampler
83
Stopping the BD High Throughput Sampler
84
Exporting an Experiment as a Template
84
Analyzing Data
86
Displaying Keywords
86
Performing Data Analysis
90
Maintaining Data
93
Returning to Tube-Based Acquisition
94
Returning to Tube-Based Acquisition on the BD LSR II
94
Returning to Tube-Based Acquisition on the BD Facscanto
97
Shutting down
100
Quitting the Software
101
Chapter 4: Maintenance
103
Daily Maintenance
104
Daily Cleaning
104
Cytometer Inspection and Servicing
109
Monthly Maintenance
111
Monthly Cleaning
111
Surface Inspection and Cleaning
114
Periodic Maintenance
114
Replacing the Sample Injection Tubing
116
Replacing the HTS Sheath Filter
119
Cleaning the Air Filter
121
Replacing the Sample Coupler and Tubing
123
Replacing a Pump Syringe
125
Replacing the Probe
129
Replacing Quick-Connector O-Rings
130
Replacing SIT Protector and O-Ring (BD LSR II Only)
130
Placing HTS Unit into Long-Term Storage
132
Unscheduled Maintenance
136
Homing the Sample Probe
136
Priming the HTS
138
Performing a Motion Test
138
Verifying the Sample Probe Position
140
Reinitializing the HTS
142
Inspecting Thumbscrew Fittings
142
Inspecting Hexagonal Fittings
143
Declogging the SIT
143
Chapter 5: Troubleshooting
145
HTS Troubleshooting
146
Acquisition Troubleshooting
147
BD Facsdiva Troubleshooting
149
Appendix A: Consumables and Replacement Parts
151
Cytometer Supplies
152
Maintenance Log
154
Appendix B: Depot Repair Procedures
157
Depot Repair Overview
158
Removing the HTS Unit
159
Cleaning the HTS Unit
162
Decontaminating the Fluidics Manually
163
Decontaminating External Surfaces
167
Unpacking the Replacement Unit
169
Lifting Heavy Objects
169
Unpacking the HTS Unit
170
Installing the HTS Unit
170
Packing the Unit for Shipping
175
Placing the HTS into Its Shipping Container
175
Index
177
BD LSR II Workbook (84 pages)
Brand:
BD
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
5
1 Introduction
7
About the Instrument
9
Power Switch
9
Control Panel
10
Fluidics
10
Optics
15
Electronics
20
Software
20
Overview
21
2 Operations and Maintenance
25
Lab Exercise: BD LSRII Startup
27
Lab Exercise: BD LSRII Shutdown
31
BD LSRII Maintenance and Care Procedures
33
Regular Maintenance
33
Periodic Maintenance
37
Laser Maintenance
42
3 Optics and Lasers
43
Lasers
45
Optical Filters
46
Optical Filters in the BD LSRII
46
4 Instrument Quality Control
55
Instrument Quality Control
57
Lab Exercise: Performing Quality Control
58
Preparing the QC Sample
58
Appendix A Worksheets
65
Appendix B Troubleshooting
71
BD LSR Overview Course Evaluation
81
Advertisement
BD LSR II User Manual (9 pages)
Flow Cytometry Analyzer
Brand:
BD
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Starting up the System
1
LSR-II 20L Pump System Instructions
2
Diva Software Instructions
2
Setting up Your Experiment
2
Calibration
3
Experiment Definition
3
Compensation
4
Running Samples
6
Basic Troubleshooting
7
Clean-Up
7
Rules
8
Notes on Data
8
Advertisement
Related Products
BD LSRFortessa
BD Logic
BD ALARIS 8015
BD FACSAria
BD FACSCalibur
BD FACSCanto II
BD FACSCelesta Flow Cytometer
BD FACSymphony A1 Flow
BD FACSymphony A3
BD Categories
Medical Equipment
Laboratory Equipment
Measuring Instruments
Refrigerator
Saw
More BD Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL