Sign In
Upload
Manuals
Brands
Aquaread Manuals
Measuring Instruments
Aquaprobe AP-5000
Aquaread Aquaprobe AP-5000 Manuals
Manuals and User Guides for Aquaread Aquaprobe AP-5000. We have
1
Aquaread Aquaprobe AP-5000 manual available for free PDF download: Instruction Manual
Aquaread Aquaprobe AP-5000 Instruction Manual (138 pages)
Multiparameter Water Quality Probe
Brand:
Aquaread
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Introduction
8
2 What's in the Box
8
The Aquameter
8
Nvironment
8
The Ap-5000 and the Environment
8
Important Notes Regarding Galvanic Corrosion
8
About the Probe Sleeve and Sleeve End Cap
9
Top Tips for Successful Measurements Using Optical Electrodes
10
3 Battery Installation and Care
11
Choice of Battery Type
11
Battery Life
11
Battery Charging
11
Battery Condition Icon
11
Battery Saver Functions
11
4 Overview of the Operating System
12
Initial Switch On, Language and Clock Setup
12
5 Connecting an Ap-5000
13
Ap-5000 Deployment (See also Section 2.3)
13
6 Taking Measurements
14
What Does It All Mean
15
Trend Indication
15
Global Stability Indication
15
Temperature Compensation
16
Gps Reception
17
7 Depth Measurement
18
Taking Depth Measurements
18
Differential Depth Measurement
18
Depth Calibration
18
8 Memory Mode
19
Manually Saving Readings
19
Recalling and Viewing Saved Readings
19
Recalling Glp Data
19
Clearing the Memory
20
Automatic Data Logging
20
Battery and Memory Duration in Low Power Logging Mode
21
Important Information about Memory Mode
22
9 Setup & Install
23
Setting Units of Measurement
23
Aux Socket Assignment
24
10 Rapidcal Calibration Method
26
About Calibration
26
Special Notes Concerning Ise Electrodes
26
Using Rapidcal
26
To Check / Calibrate the 100% Saturation Point in Damp Air
28
Calibration Error Messages
29
Resetting to Factory Calibration Defaults
30
Calibration Reports
30
Calibration Data Storage and Retrieval
30
11 After Use
32
12 General Probe Maintenance
33
Identifying the Individual Electrodes
33
13 Ph/Orp Electrode Calibration and Maintenance
34
Recognising the Ph/Orp Electrode
34
Electrode Removal and Replacement
34
Keeping the Electrodes Moist
34
Calibrating Ph
35
Special Notes Concerning ISE Electrodes During Ph Calibration
35
Calibrating the First Point (Ph 7.00)
35
Calibrating the Second Point
37
Calibrating the Third Point
37
Errors During Calibration
37
Ph Electrode Efficiency
37
Servicing the Ph Electrode
37
Calibrating Orp
38
Converting Orp Readings to the Hydrogen Scale
40
14 Do/Ec Electrode Calibration and Maintenance
41
Recognising the Do/Ec Electrode
41
Do Measurement Technique
41
Precautions During Use
41
Calibrating the Do/Ec Electrode
41
Calibrating the Do Zero Point
41
Calibrating the Do 100% Saturation Point in Moist Air
43
Replacing the Optical Do Cap
43
Calibrating Ec
45
Verifying Ec Calibration
47
Errors During Calibration
47
Cleaning the Ec Contacts
47
Calibrating Temperature
48
15 Optional Optical Electrodes Calibration and Maintenance
49
Top Tips for Successful Measurements Using Optical Electrodes
49
Optical Electrode Calibration Sequence
50
Fluorescent Electrode Grab Sample Correction Factor
50
2000/5000-Turb Turbidity Electrode
51
About Turbidity
51
Precautions During Use
51
Negative Turbidity Readings
52
Calibrating the Turbidity Electrode
52
Calibration Points
52
Turbidity Zero Point Calibration
53
Verifying the Zero Calibration
54
Calibrating the Turbidity 20 NTU & 1000 NTU Points
54
Errors During Calibration
55
Lens and Sleeve Maintenance
55
2000/5000-BGA-PC Freshwater Blue-Green Algae (Phycocyanin) Electrode
56
Principle of Operation
56
Limitations of Use
56
Calibrating the BGA-PC Electrode
56
Calibration Solution Preparation
57
Serial Dilution
57
Zero Point Calibration
58
Calibrating Point 2
59
Calculating and Applying a Grab Sample Factor
59
Errors During Calibration
60
Lens and Sleeve Maintenance
60
2000/5000-BGA-PE Saltwater Blue-Green Algae ( Phycoerythrin ) Electrode
61
Principle of Operation
61
Limitations of Use
61
Calibrating the BGA-PE Electrode
61
Calibration Solution Preparation
62
Serial Dilution
62
Zero Point Calibration
63
Calibrating Point 2
64
Calculating and Applying a Grab Sample Factor
64
Errors During Calibration
65
Lens and Sleeve Maintenance
65
2000/5000-Cphyll Chlorophyll Electrode
66
Principle of Operation
66
Limitations of Use
66
Calibrating the CPHYLL Electrode
66
Calibration Solution Preparation
67
Serial Dilution
67
Zero Point Calibration
68
Calibrating Point 2
69
Calculating and Applying a Grab Sample Factor
69
Errors During Calibration
70
Lens and Sleeve Maintenance
70
2000/5000-Rhod Rhodamine Electrode
71
Principle of Operation
71
Limitations of Use
71
Calibrating the RHOD Electrode
71
Calibration Solution Preparation
71
Serial Dilution
72
Zero Point Calibration
72
Calibrating Point 2
74
Grab Sample Factor
74
Errors During Calibration
74
Lens and Sleeve Maintenance
74
2000/5000-Fscein Fluorescein Electrode
75
Principle of Operation
75
Limitations of Use
75
Calibrating the FSCEIN Electrode
75
Calibration Solution Preparation
75
Serial Dilution
76
Zero Point Calibration
76
Calibrating Point 2
78
Grab Sample Factor
78
Errors During Calibration
78
Lens and Sleeve Maintenance
78
2000/5000-Refoil Refined Oil Electrode
79
Principle of Operation
79
Limitations of Use
79
Special Precautions When Using the REFOIL Electrode
80
Calibrating the REFOIL Electrode
80
Calibration Solution Preparation
80
Serial Dilution
80
Zero Point Calibration
81
Calibrating Point 2
82
Calculating and Applying a Grab Sample Factor
83
Errors During Calibration
83
Lens and Sleeve Maintenance
83
2000/5000-Cdom/Fdom C
85
Principle of Operation
85
Hromophoric (Fluorescent ) Dissolved Organic Matter
85
Limitations of Use
85
Calibrating the CDOM Electrode
86
Calibration Solutions
86
Zero Point Calibration
86
Calibrating Point 2
88
Calculating and Applying a Grab Sample Factor
88
Errors During Calibration
89
Lens and Sleeve Maintenance
89
Special Note Concerning CDOM Calibration Solutions
89
16 Optional Ise Electrodes Calibration and Maintenance
90
Ise Electrode Limitations
90
Calibration Points
90
Special Notes Concerning Ise Electrodes
90
5000/7000-AMM Ammonium/Ammonia Electrode
91
Ammonium Calibration Solution Preparation
91
Three-Point Calibration
91
Point 2
93
Point 3
93
Two-Point Calibration
94
Single-Point Calibration
94
Errors During Calibration
94
5000/7000-Nit Nitrate Electrode
95
Nitrate Calibration Solution Preparation
95
Three-Point Calibration
95
Point 2
97
Two-Point Calibration
98
Single-Point Calibration
98
Errors During Calibration
98
5000/7000-Chl Chloride Electrode
99
Chloride Calibration Solution Preparation
99
Three-Point Calibration
99
Point 2
101
Point 3
101
Two-Point Calibration
102
Single-Point Calibration
102
Errors During Calibration
102
5000/7000-Cal Calcium Electrode
103
Calcium Calibration Solution Preparation
103
Three-Point Calibration
103
Point 2
105
Point 3
105
Two-Point Calibration
106
Single-Point Calibration
106
Errors During Calibration
106
5000/7000-Flu Fluoride Electrode
107
Fluoride Calibration Solution Preparation
107
Three-Point Calibration
108
Point 2
108
Point 3
109
Two-Point Calibration
110
Single-Point Calibration
110
Errors During Calibration
110
17 Aqualink Pc Software
111
Downloading Aqualink ™ PC Software from the Aquaread
111
Software Installation
111
Website
111
Driver Installation
111
Running Aqualink
111
Uploading Data from Your Aquameter
112
Displaying GPS Co-Ordinates
112
O Nscreen Help
113
Saving Logged Data
113
Retrieving Logged Data
113
Exporting Data
113
Exporting Text Reports
113
Typical Text Report Cover Page
115
Exporting Excel Files
116
Exporting Google™ Files
116
Importing Files into Google™ Earth
116
Google™ Example
117
18 Limited Warranty
118
Cleaning Prior to Return
118
Decontamination Certificate
119
19 Troubleshooting
120
20 Declaration of Conformity
121
21 Appendix 1. the Tech Behind Aquaread's Optical Do Measurement System
122
Principle of Operation
122
Sensor Cap Life
123
22 Appendix 2. Installing Aux Electrodes
124
Fitting Aux Electrodes
124
Socket Assignment and Calibration
125
23 Appendix 3. Standard Electrodes Detailed Specification
126
24 Appendix 4. Optical Electrodes Detailed Specification and Faqs
127
What Are the Excitation and Detection Wavelengths
127
How Does the Refined Oil Sensor Work
127
Ican See Algae in the Water but My Sensor Is Giving Low Readings . Why
128
What Is the Range and Resolution of the Optical Electrodes
128
What Is the Accuracy of the Optical Electrodes
129
25 Appendix 4. Ise Electrodes Detailed Specification
130
Special Notes Concerning ISE Electrodes and Ph Buffers
131
26 Appendix 7. Troubleshooting Turbidity
132
Lens and Sleeve Maintenance
132
About Turbidity Measurement
133
Precautions During Use
133
Negative Turbidity Readings
133
Aeration
134
Reflection
134
Sensor Saturation
134
Top Tips for Successful Measurements Using Optical Electrodes
135
References
136
27 Appendix 8. Flow through Cell
137
Spigot Installation
137
Ap-5000 Preparation Prior to Use
137
Ap-5000 Installation into the Flowcell
138
Flowcell Operation
138
Caution
138
Flowcell Cleaning
138
Flowcell Troubleshooting
138
Advertisement
Advertisement
Related Products
Aquaread Aquaprobe AP-800
Aquaread Aquaprobe AP-2000
Aquaread AquaTelemetry
Aquaread Aquaprobe Lite
Aquaread Aquaprobe AP-7000
Aquaread Aquaprobe AP-6000
Aquaread Aquaprobe AP-7000Mk2
Aquaread Aquaprobe AP-700
Aquaread LeveLine
Aquaread LeveLine Baro
Aquaread Categories
Measuring Instruments
Media Converter
Analytical Instruments
More Aquaread Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL