Manuals and User Guides for Aquaread Aquaprobe AP-2000. We have
1
Aquaread Aquaprobe AP-2000 manual available for free PDF download: Instruction Manual
Aquaread Aquaprobe AP-2000 Instruction Manual (141 pages)
Multiparameter Water Quality Probe and associated
Brand:
Aquaread
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
What's New in this Manual
3
Table of Contents
4
1 Introduction
9
2 What's in the Box
9
The Aquameter ® and the Environment
9
The Aquaprobe ® and the Environment
9
Important Information about the Probe Sleeve & Sleeve End Cap
10
Top Tips for Successful Measurements Using Optical Electrodes
11
About the Lanyard
11
3 Battery Installation and Care
12
Choice of Battery Type
12
Battery Life
12
Battery Charging
12
Battery Condition Icon
12
Battery Saver Functions
12
4 Overview of the Operating System
13
Initial Switch On, Language and Clock Setup
13
5 Connecting an Ap-2000
14
Connecting the Aquameter
14
6 Taking Measurements
14
What Does It All Mean
15
Trend Indication
16
Global Stability Indication
16
Temperature Compensation
16
Gps Reception
17
7 Depth Measurement (Aquaprobes with a - D Suffix Only)
19
Taking Depth Measurements
19
Differential Depth Measurement
19
Depth Calibration
19
8 Memory Mode
20
Manually Saving Readings
20
Recalling and Viewing Saved Readings
20
Recalling Glp Data
20
Clearing the Memory
21
Automatic Data Logging
21
Battery and Memory Duration in Low Power Logging Mode
23
Important Information about Memory Mode
23
9 Setup & Install
24
Setting Units of Measurement
24
AUX Socket Assignment (Not Applicable to the AP-700)
25
10 Rapidcal Calibration Method
27
About Calibration
27
Special Notes Concerning Ise Electrodes
27
Using Rapidcal
27
To Check / Calibrate the 100% DO Saturation Point in Damp Air
29
Calibration Error Messages
30
Resetting to Factory Calibration Defaults
30
Calibration Reports
31
Calibration Data Storage and Retrieval
31
11 After Use
33
12 General Probe Maintenance
34
Identifying the Individual Electrodes
34
13 Ph/Orp Electrode Calibration and Maintenance
35
Recognising the Ph/Orp Electrode
35
Electrode Removal and Replacement
35
Keeping the Electrodes Moist
35
Calibrating Ph
36
Special Notes Concerning Ise Electrodes
36
Calibrating the First Point (Ph 7.00)
36
Calibrating the Second Point
38
Calibrating the Third Point
38
Errors During Calibration
38
Ph Electrode Efficiency
38
Servicing the Ph Electrode
38
Calibrating Orp
39
Converting Orp Readings to the Hydrogen Scale
41
14 Do Electrode Calibration and Maintenance
42
Recognising the Do Electrode Type
42
Galvanic Do Electrode
42
Precautions During Use
42
Calibrating the Galvanic Do Electrode
42
Calibrating the DO Zero Point
42
Calibrating the DO 100% Saturation Point in Moist Air
43
Replacing a Galvanic Do Electrode Membrane Cap
44
Optical Do Electrode
45
Calibrating the Optical Do Electrode
45
Calibrating the Do Zero Point
45
Calibrating the Do 100% Saturation Point in Moist Air
46
Replacing the Optical Do Cap
47
15 Ec / Temperature Electrode Calibration and Maintenance
48
Verifying Ec Calibration
50
Errors During Calibration
50
Cleaning the Ec Contacts
50
Calibrating Temperature
50
16 Optional Optical Electrodes Calibration and Maintenance
52
Top Tips for Successful Measurements Using Optical Electrodes
53
Optical Electrode Calibration Sequence
53
Fluorescent Electrode Grab Sample Correction Factor
53
2000-Turb Turbidity Electrode
54
About Turbidity
54
Turbidity Electrode Installation
54
Precautions During Use
55
Negative Turbidity Readings
55
Calibrating the Turbidity Electrode
55
Calibration Points
55
Turbidity Zero Point Calibration
56
Verifying the Zero Calibration
57
Calibrating the Turbidity 20 NTU & 1000 NTU Points
57
Errors During Calibration
58
Lens and Sleeve Maintenance
58
2000/5000-BGA-PC Freshwater Blue-Green Algae (Phycocyanin) Electrode
59
Principle of Operation
59
Limitations of Use
59
Calibrating the BGA-PC Electrode
59
Calibration Solution Preparation
60
Serial Dilution
60
Zero Point Calibration
61
Calibrating Point 2
62
Calculating and Applying a Grab Sample Factor
62
Errors During Calibration
63
Lens and Sleeve Maintenance
63
2000/5000-BGA-PE Saltwater Blue-Green Algae ( Phycoerythrin ) Electrode
64
Principle of Operation
64
Limitations of Use
64
Calibrating the BGA-PE Electrode
64
Calibration Solution Preparation
65
Serial Dilution
65
Zero Point Calibration
66
Calibrating Point 2
67
Calculating and Applying a Grab Sample Factor
67
Errors During Calibration
68
Lens and Sleeve Maintenance
68
2000/5000-Cphyll Chlorophyll Electrode
69
Principle of Operation
69
Limitations of Use
69
Calibrating the CPHYLL Electrode
69
Calibration Solution Preparation
70
Serial Dilution
70
Zero Point Calibration
71
Calibrating Point 2
72
Calculating and Applying a Grab Sample Factor
72
Errors During Calibration
73
Lens and Sleeve Maintenance
73
2000/5000-Rhod Rhodamine Wt Electrode
74
Principle of Operation
74
Limitations of Use
74
Calibrating the RHOD Electrode
74
Calibration Solution Preparation
74
Serial Dilution
75
Zero Point Calibration
75
Calibrating Point 2
77
Grab Sample Factor
77
Errors During Calibration
77
Lens and Sleeve Maintenance
77
2000/5000-Fscein Fluorescein Wt Electrode
78
Principle of Operation
78
Limitations of Use
78
Calibrating the FSCEIN Electrode
78
Calibration Solution Preparation
78
Serial Dilution
79
Zero Point Calibration
79
Calibrating Point 2
81
Grab Sample Factor
81
Errors During Calibration
81
Lens and Sleeve Maintenance
81
2000/5000-Refoil Refined Oil Electrode
82
Principle of Operation
82
Limitations of Use
82
Special Precautions When Using the REFOIL Electrode
83
Calibrating the REFOIL Electrode
83
Calibration Solution Preparation
83
Serial Dilution
83
Zero Point Calibration
84
Calibrating Point 2
85
Calculating and Applying a Grab Sample Factor
86
Errors During Calibration
86
Lens and Sleeve Maintenance
86
2000/5000-CDOM/FDOM Chromophoric (Fluorescent) Dissolved Organic Matter
87
Principle of Operation
87
Hromophoric (Fluorescent ) Dissolved Organic Matter
87
Limitations of Use
87
Calibrating the CDOM Electrode
88
Calibration Solutions
88
Zero Point Calibration
88
Calibrating Point 2
90
Calculating and Applying a Grab Sample Factor
90
Errors During Calibration
91
Lens and Sleeve Maintenance
91
17 Optional Ise Electrodes Calibration and Maintenance
92
Ise Electrode Limitations
92
Calibration Points
92
Special Notes Concerning ISE Electrodes During Ph Calibration
92
2000-AMM Ammonium/Ammonia Electrode
93
Ammonium Calibration Solution Preparation
93
Three-Point Calibration
93
Point 2
95
Point 3
95
Two-Point Calibration
96
Single-Point Calibration
96
Errors During Calibration
96
2000-Nit Nitrate Electrode
97
Nitrate Calibration Solution Preparation
97
Three-Point Calibration
97
Point 2
99
Point 3
99
Two-Point Calibration
100
Single-Point Calibration
100
Errors During Calibration
100
2000-Chl Chloride Electrode
101
Chloride Calibration Solution Preparation
101
Three-Point Calibration
101
Point 2
103
Point 3
103
Two-Point Calibration
104
Single-Point Calibration
104
Errors During Calibration
104
2000-Cal Calcium Electrode
105
Calcium Calibration Solution Preparation
105
Three-Point Calibration
105
Point 2
107
Point 3
107
Two-Point Calibration
108
Single-Point Calibration
108
Errors During Calibration
108
2000-Flu Fluoride Electrode
109
Fluoride Calibration Solution Preparation
109
Three-Point Calibration
110
Point 2
110
Point 3
111
Two-Point Calibration
112
Single-Point Calibration
112
Errors During Calibration
112
18 Aqualink Pc Software
113
Software Installation
113
Website
113
Driver Installation
113
Running Aqualink
113
Uploading Data from Your Aquameter
114
Displaying Gps C Oordinates
114
O Nscreen Help
115
Saving Logged Data
115
Retrieving Logged Data
115
Exporting Data
115
Exporting Text Reports
115
Typical Text Report Cover Page
117
Exporting Excel Files
118
Exporting Google™ Files
118
Importing Files into Google™ Earth
118
Google™ Example
119
19 Limited Warranty
120
Cleaning Prior to Return
120
Decontamination Certificate
121
20 Troubleshooting
122
21 Declaration of Conformity
123
22 Appendix 1. the Tech Behind Aquaread's Optical Do Measurement System
124
Principle of Operation
124
Sensor Cap Life
125
23 Appendix 2. Flow through Cell
126
Introduction
126
Spigot Installation
126
Aquaprobe ® Installation
126
Zeroing Optical Electrodes
126
Operation
126
Caution
127
Cleaning
127
Flowcell Troubleshooting
127
24 Appendix 3. Fitting Aux Electrodes
128
Installing Aux Electrodes
128
Socket Assignment and Calibration
129
25 Appendix 4. Standard Electrodes Detailed Specification
131
26 Appendix 5. Optical Electrodes Detailed Specification and Faqs
132
What Are the Excitation and Detection Wavelengths
132
How Does the Refined Oil Sensor Work
132
Ican See Algae in the Water but My Sensor Is Giving Low Readings . Why
133
What Is the Range and Resolution of the Optical Electrodes
133
What Is the Accuracy of the Optical Electrodes
134
27 Appendix 6. Ise Electrodes Detailed Specification
135
Special Notes Concerning ISE Electrodes During Ph Calibration
136
28 Appendix 7. Troubleshooting Turbidity
137
Lens and Sleeve Maintenance
137
About Turbidity Measurement
138
Precautions During Use
138
Negative Turbidity Readings
138
Aeration
139
Reflection
139
Sensor Saturation
139
Ltd
140
Top Tips for Successful Measurements Using Optical Electrodes
140
References
141
Advertisement
Advertisement
Related Products
Aquaread Aquaprobe AP-800
Aquaread AquaTelemetry
Aquaread Aquaprobe AP-5000
Aquaread Aquaprobe Lite
Aquaread Aquaprobe AP-7000
Aquaread Aquaprobe AP-6000
Aquaread Aquaprobe AP-7000Mk2
Aquaread Aquaprobe AP-700
Aquaread LeveLine
Aquaread LeveLine Baro
Aquaread Categories
Measuring Instruments
Media Converter
Analytical Instruments
More Aquaread Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL