The GC 5000 BTX
AMA Instruments The GC 5000 BTX Manuals
Manuals and User Guides for AMA Instruments The GC 5000 BTX. We have
2
AMA Instruments The GC 5000 BTX manuals available for free PDF download: Operating Manual
AMA Instruments The GC 5000 BTX Operating Manual (152 pages)
Gas chromatograph
Brand:
AMA Instruments
| Category:
Laboratory Equipment
| Size: 7 MB
Table of Contents
Table of Contents
3
Information for the Owner
7
How to Use the Manual
7
Specific Normal Operation
7
Delivery Information
8
Standard and Regulations
9
Declaration of Conformity
9
Copyright
10
Service Address
10
Hazard Information
11
General Hazard Information
11
Responsibility of the Operator
12
Product Description - Technical Specifications
13
Normal Use of GC 5000 BTX
13
Hardware Description
14
Description of GC Components
16
System Control and Watchdog
16
GC Oven
16
Columns
16
Detector
16
Setup of Parameters
16
Technical Data GC 5000 BTX
17
Options
19
Calibration Gas Selector (Optional)
19
Ozone Precursor Monitoring System (Optional)
19
Optional Modules
20
Dilution Module DIM 200
20
Sample Stream Selector SSM 600
21
Installation
23
Safety Instructions
23
Installation Condition
24
Gas Connections
24
Electrical Connections
25
Start up and Shut down
26
Safety Instructions
26
Start up Instructions
27
Decommissioning
29
Setting up the GC 5000 Software
30
Status Screen
30
How to Unlock - Password Protection
32
How to Select Operation Modes
33
How to Select Master Modes
33
How to Select Communication Parameters
34
Analog Outputs Configuration
34
Alarm Configuration
36
Gesytec Specifications
37
Modifying Parameters under "Gesytec Specifications
37
Starting Operation
40
How to Start Measurement
40
How to Adjust the Retention Time Windows
43
How to Zoom / Zoom out the Chromatogram
47
How to Optimize Integration Parameters
49
Using LCD Display and Buttons on the Front Panel
50
Calibrating and Validating
53
Calibration
53
Calibration Intervals
53
How to Enter the Data of Calibration Gas Concentrations
54
Enter Data - Without a Calibration Gas Module
54
How to Disable Concentration Levels
54
Enter Data - with a Calibration Gas Module
55
How to Start a Calibration
57
Calibration of One Level
57
Calibration of Sequence (Without Calibration Module or Cal. Valves)
58
Auto-Calibration
59
Validation
60
Principle of Validation
60
Types of Validation
60
How to Start Validation
61
Functional Description
66
Measuring Principle
66
Definition of the Program Step
67
Program Example
69
Software Reference
70
Basic Software Design
70
Software Architecture
70
Configuration Files
70
Main Window: Program
71
Menu Items
73
Unlock
74
Parameters
75
Change Password
75
Operation Mode
75
Remote Control
76
Master Mode
79
Method
79
Analysis
80
GC Oven
81
Calibration
83
Validation Setup
86
Analog Output Configuration
87
Alarm Configuration
88
CP Analysis
89
CP File Editor
90
Module Setup
99
Program Steps
100
Standard BTX
100
BTX with Stripper Column
103
View
106
Run Calibration (Manual and Auto-Calibration)
109
Run Validation
111
Help Functions
112
Remote Support
112
About (Current Software Version)
112
Miscellaneous Procedures
113
Programming and Editing Values
113
Programming GC Oven Parameters
114
How to Display the Running Temperature Program
114
Select the Parameters for the Running Temperature Program
115
Start and Stop
116
Subsequent Data Processing
118
Maintenance
121
Security Instructions
121
Maintenance Schedule
122
Maintenance Work
123
Exchange the Enrichment Tube
123
Maintenance of the Pump
124
Exchange the Input Filter of the MFC
124
Exchange or Repair the Capillary Column
125
Adjust the Detector Signal
127
Check the Glow Plug
127
Check the Thermocouples
128
Check the Heating Units of Detector and Valve Oven
128
Exchange of the PID Lamp
129
Clean the PID Lamp Window
130
Exchange the Rotor of the Rotary Valve
130
Exchange the GC Oven Motor
132
Exchange the Back Panel Fan
132
Exchange the Peltier Cooler Fan
133
FID Maintenance
133
Troubleshooting
134
General Faults
134
Alarm Messages
136
Warning Messages
140
Error Messages
141
Spare Parts List
142
Warranty
143
GESYTEC-II Protocol
144
Telegram Definitions
144
Status Request MZ
144
Status Response ZM
144
Data Request da
146
Data Response AD
146
Control Command ST
148
Control Response TS
148
Appendix
149
Digital I/O
150
General
150
Digital Outputs
151
Digital Inputs
152
Advertisement
AMA Instruments The GC 5000 BTX Operating Manual (105 pages)
Gas Chromatograph
Brand:
AMA Instruments
| Category:
Laboratory Equipment
| Size: 8 MB
Table of Contents
Table of Contents
3
Information for the Owner
6
How to Use the Manual
6
Specific Normal Operation
6
Delivery Information
7
Standard and Regulations
8
Declaration of Conformity
8
Copyright
9
Service Address
9
Hazard Information
10
General Hazard Information
10
Responsibility of the Operator
11
Product Description - Technical Specifications
12
Normal Use of GC 5000 BTX
12
Normal Use of GC 5000 VOC
13
Normal Use of GC 5000 Process
13
Hardware Description
14
Description of GC Components
16
System Control and Watchdog
16
GC Oven
16
Columns
16
Detector
16
Setup of Parameters
16
Technical Data GC 5000
17
Options
19
Calibration Gas Selector (Optional)
19
Ozone Precursor Monitoring System (Optional)
19
Optional Modules (Accessories for GC 5000)
20
Dilution Calibrator DIM 200
20
Zero Air Generator ZAG 300
22
Hydrogen Generators - HG 300 and HG 500
23
Installation
25
Safety Instructions
25
Installation Condition
26
Gas Connections
26
Electrical Connections
27
Start up and Shut down
28
Safety Instructions
28
Start up Instructions
29
Decommissioning
31
Setting up the GC 5000 Software
32
Control Tab
32
Status Tab
33
Events Tab
34
How to Unlock - Password Protection
35
Control Modes
36
Communication Parameters (Optional)
36
Starting Operation
39
How to Start Measurement
39
How to Adjust the Retention Time Windows
43
How to Stop Measurements
45
Calibrating and Validating
46
Calibration
46
Calibration Intervals
46
Calibration Setup
46
How to Start a Calibration
48
Check the Results of the Calibration
52
Validation
56
Principle of Validation
56
Types of Validation
56
Validation Setup
57
How to Start Validation
59
Check the Validation Status
60
Time Program
61
How to Setup the Time Program
61
How to Start the Time Program
62
Functional Description
64
Measuring Principle BTX
64
Measuring Principle VOC
65
Measuring Principle Process
67
Maintenance
68
Security Instructions
68
Maintenance Schedule
69
Maintenance Work
70
Exchange the Enrichment Tube (BTX)
70
Maintenance of the Pump
71
Exchange the Input Filter of the MFC
71
Exchange or Repair the Capillary Column
72
Adjust the Detector Signal
74
Adjust the Ignition Voltage
74
Check the Glow Plug
74
Check the Thermocouples
75
Check the Heating Units of Detector and Valve Oven
75
Exchange of the PID Lamp
76
Clean the PID Lamp Window
77
Exchange the Rotor of the Rotary Valve
77
Exchange the GC Oven Motor
79
Exchange the Back Panel Fan
79
Exchange the Peltier Cooler Fan (BTX)
80
FID Maintenance
80
Exchange the Enrichment or Focusing Tube (VOC)
81
Exchange the Peltier Cooler Fan (VOC)
82
Troubleshooting
83
General Faults
83
Error Messages
85
Warning Messages
89
Spare Parts List
90
Warranty
91
GESYTEC-II Protocol
92
Telegram Definitions
92
Status Request MZ
92
Status Response ZM
93
Data Request da
94
Data Response AD
94
Control Command ST
96
Control Response TS
96
Appendix
97
Analog Outputs
98
Analog Outputs Connection
98
Analog Outputs Configuration
99
Digital I/O
101
General
101
Digital Outputs
102
Digital Inputs
104
Digital Outputs for External Calibrators
105
Advertisement
Related Products
AMA Instruments GC 5000 Series
AMA Instruments GC 5000 PROCESS
AMA Instruments The GC 5000 VOC