Download Print this page

Maytag 53-3442 Installation Instructions Manual

Automatic dryer

Advertisement

Quick Links

'h
'1,
PLEASE READ ALL INSTALLATION
INSTRUCTIONS AND REQUIREMENTS
BEFORE INSTALLING
ELECTRIC
WARNING
OR'IOUR
SAFETY
Do not store or use gasoline or other
flammable
vapors or liquids in the
vicinity of this or any other appliance.
%
3/8"DEEP WELL DRIVER
CHANNEL LOCK PLIERS
SCREWDRIVER
PUTTY KNIFE
DUCT TAPE
1/,,- DRIVER
OR ADJUSTABLE WRENCH
(BLADE & TORX)
INSTALLINGYOUR NEW DRYER
BACKGUARD
/
FORYOUR SAFETY AND THE PROPER OPERA-
//
/
TION OFYOUR NEW DRYER,THE DRYER
MUST BE INSTALLEDIN ACCORDANCEWITH
1\
\\
ALL THE INSTALLATIONREQUIREMENTS.
All literatureshouldbe removedfrom insidedryerand
-
savedfor future reference.
["
NOTE:DO NOTRAISEOR LOWER THE DRYERBY
THE BACKGUARD.
1. To removethe corrugatedcrate base,placeyour
_-
foot on the base close to a levelingfoot. Pushing
downfirmly with yourfoot, tilt the dryerawayfrom
you.
2. Repeatprocesswithall levelingfeet (4). Remove
_---. _. -_
,
excessbase by hand.
CORRUGATED
CRATE
PLACE FOOT
P/N 53-3442
BASE
FOR LEVERAGE
1

Advertisement

loading

Summary of Contents for Maytag 53-3442

  • Page 1 1. To removethe corrugatedcrate base,placeyour foot on the base close to a levelingfoot. Pushing downfirmly with yourfoot, tilt the dryerawayfrom you. 2. Repeatprocesswithall levelingfeet (4). Remove excessbase by hand. P/N 53-3442 ELECTRIC SCREWDRIVER PUTTY KNIFE (BLADE & TORX) BACKGUARD ["...
  • Page 2 NSTALLATION REC!UREMENTS PLEASE READ All Installation Instructions and Requirements Before Installing Power Cord. IT IS RECOMMENDED THAT A QUALIRED ELECTRk ClAN OR SERVICETECHNICIAN INSTALLYOUR DRYER. LOCATION This clothes dryer is designed so that installed in most locations in the home. The dryer may even be installed in an unheated indoor location, such as a utility room or building.
  • Page 3 3. Route the power cord (pigtail) or cable conductors through the strain relief clamp. CAUTION - The conductors should not extend into connections. the dryer more than necessary to make the electrical 4. Refer to the Typical Electrical connections listed below and make the electrical connections as instructed.
  • Page 4 1. LEVELING FOOT Set all leveling feet at same height. A minimum of Y2' c learance between the machine and the floor is recommend- ed. Adjust to match the height of your dryer, 3A. OUTSIDEWALL OUTSIDEWALL-- exhaust vent. Outside exhaust vent should fit over dryer vent pipe to avoid catching lint.Tape all joints with heat duct tape.
  • Page 5 EXHAUST VENTING RECUIREMENTS WARNINI FIRE HAZARD NEVER EXHAUST INTO A CHIMNEY, DUCT, GAS VENT, WALL, CEILING, ATTIC, CONFINED SPACE, BEDROOM, OR UNDER A BUILDING. DO NOT USE VINYL, PLASTIC, CLOTH OR OTHER NONMETALIC DUCT TO EXHAUST THE DRYER. MULTIPLE INSTALLATIONS REQUIRE INDIVIDUAL EXHAUST SYSTEMS.
  • Page 6 Saw a 4',_ " hole in floor and position dryer. 10. Secure the shortened pipe to the blower housing with a screw at the top and seal all joints with tape or silicone bathtub caulk. 11. Install a 4" 90 degree elbow as shown. FIG.