Scanner Function - Sharp AL-2060 Operation Manual

Digital multifunctional system
Hide thumbs Also See for AL-2060:
Table of Contents

Advertisement

APPENDIX

Scanner Function

Type
Scanning method
Light source
Resolution
Original types
Effective scanning
area
Scanning speed
Input Data
Output Data
Scanning colors
Protocol
Interface
Drop out color
Supported
operating systems
Void area
Interface cables
Scanner utilities
Note
94
Flatbed scanner
Document glass /RSPF
Tri-color CCD light source
(CCD: 3 components; R, G, and B)
Basic: 600 dpi x 1200 dpi
Setting range: 50dpi - 9600dpi
Sheet media, books
216 mm (Lengthwise) x 356 mm (Width)
2.88 msec/line
1 bit or 12 bit
R.G.B 1 or 8 bits / pixel / A/D 16 bit
Black and white 2 value, Grayscale, Full color
TWAIN
WIA (Windows XP/Vista only)
STI
USB 2.0 (Full-Speed/Hi-Speed compatible interface)
Yes
Windows98/Me/2000 Professional/XP/Vista
(Detailed information can be found in "BEFORE
INSTALLATION" (p.41))
None
[USB cable]
USB cable that supports USB 2.0.
Please purchase a commercially available USB cable.
Button Manager / Sharpdesk
As a part of our policy of continuous improvement, SHARP reserves
the right to make design and specification changes for product
improvement without prior notice. The performance specification
figures indicated are nominal values of production units. There may
be some deviations from these values in individual units.