Toshiba FT-8930 Service Manual page 5

Table of Contents

Advertisement

Receiver Section
Connections
AC 120V
60Hz
Preset
Place the Base Unit in RX SENS mode (step 4) in accordance with the precedure on page 3.
Alignment Procedure
step
Preset to
Adjustment
SG: 1mV
1
(Discriminator
No modulation
SG: 1mV
2
1 kHz ±8kHz
deviation
SG: -113dBµ µ µ µ µ V
3
No modulation
(SQ Point)
Alignment Point Location on Base Main PCB and Base RF PCB
Base Main PCB
RF SG
RF
-
Test Point
+
J4
DC IN 9V Jack
AC
Adapter
Connect the RF Signal Generator to the RF test point on the Base MAIN
L4
PCB. Make sure that the frequency is 902.952467 MHz.
Connect the DC Voltmeter to the AF test point. Adjust L4 to indicate DC
Voltage)
1.00 V.
RT2
Connect the AC Voltmeter across a 600-ohm dummy to the Telephone Line
(RX AF
Jack. Adjust RT2 for a -11dBm reading on the AC voltmeter.
Voltage)
Press the "PAGE" key to enter the TEST Mode 5. Make sure that the
RT1
frequency of RF SG output is 902.952467 MHz. Adjust RT1 to turn to the
point where the LED indication is just vibrated.
RT1
RT2
L4
S4
S3
AF Test Point
BASE Unit
Dummy Load
(600-ohm)
J1
TEL Line
-
Jack
+
AF
DC Voltmeter
Test Point
Remarks
RF Test Point
4
AC Voltmeter
J1
TEL LINE Jack
J4
DC IN 9V Jack
TONE
S1
PULSE/TONE Switch
PULSE
ON
S2
RINGER OFF-ON Switch
OFF