PHYSICAL DATA AND SPECIFICATIONS
U.S. AND CANADA MODELS (DOWNFLOW)
MODEL NUMBERS
RGLQ- SERIES
High Input–BTU–BTU/Hr [kW] ➁
Heating Capacity–BTU/Hr [kW] ➀
Low Input–BTU/Hr [kW]
Heating Capacity–BTU/Hr [kW]
Heating–Ext. Static Pressure [kPa]
Blower (D x W) [mm]
Motor H.P.–[W]
Speeds–Type
Motor Full Load Amps
Heating Speed–High Fire
Heating Speed–Low Fire
Cooling Speed
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
Max. E.S.P. (In. W.C.) [kPa]
Temperature Rise Range °F [°C]
High Input
Temperature Rise Range °F [°C]
Low Input
Max. Outlet Air Temp. °F
[°C]
Standard Filter–In.
[mm]
Approx. Shipping Weight (Lbs.)
[kg]
AFUE ➀
NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is
➀ In accordance with D.O.E. test procedures.
➁ See Conversion Kit Index for high altitude derate in U.S. applications. For Canadian applications, reference the furnace installation instructions.
MODEL IDENTIFICATION—DOWNFLOW MODELS
R
G
L
Rheem
Gas
Downflow
Design
Furnace
Series
[ ] Designates Metric Conversions
05EAUER
07EAMER
05NAUER
07NAMER
50,000 [15]
75,000 [22]
40,360 [12]
61,020 [18]
35,000 [10]
52,500 [15]
28,000 [8]
41,600 [12]
.10 [.025]
.12 [.029]
11 x 6
11 x 7
[279 x 152]
[279 x 178]
1
/
[373]
1
/
[373]
2
2
4-PSC
4-PSC
6.8
7.1
MED-LOW
MED-HIGH
LOW
MED-LOW
HIGH
HIGH
1200
1200
[566]
[566]
0.5 [.12]
0.5 [.12]
25-55
35-65
[13.9-30.6]
[19.4-36.1]
20-50
30-60
[11.1-27.8]
[16.7-33.0]
155
165
[68.3]
[78.3]
(1) 14 x 20
(2) 12 x 20
[356 x 508]
[306 x 508]
85
105
[39]
[48]
80.0%
80.0%
Q
07E
Heating Input Designation
Electric
Electric
Ignition–
Ignition
NO
Models
x
05E
05N
07E
07N
10E
10N
12E
12N
15E
15N
10EAMER
10NAMER
100,000 [29]
81,600 [24]
70,000 [20]
56,000 [16]
.15 [.037]
11 x 7
[279 x 178]
1
/
[373]
2
4-PSC
7.1
MED-HIGH
LOW
HIGH
1200
[566]
0.5 [.12]
45-75
[25.0-41.7]
20-50
[11.1-27.8]
180
[82.2]
(2) 12 x 20
[306 x 508]
115
[52]
80.0%
1
/
" [12.7 mm] N.P.T.
2
A
Variations
A = Std.
Cabinet
U = 11 x 6
Input
B = Wide
BTU/HR
Cabinet
M = 11 x 7
50,000 [15 kW]
75,000 [22 kW]
R = 11 x 10
100,000 [29 kW]
125,000 [37 kW]
150,000 [44 kW]
Rheem Heating, Cooling and Water Heating
10EBRJR
12EARJR
10NBRJR
12NARJR
100,000 [29]
125,000 [37]
81,040 [24]
101,750 [29]
70,000 [20]
87,500 [25]
56,000 [16]
70,000 [20]
.15 [.037]
.20 [.05]
11 x 10
11 x 10
[279 x 254]
[279 x 254]
3
/
[559]
3
/
[559]
4
4
4-PSC
4-PSC
9.5
9.5
MED-HIGH
MED-HIGH
LOW
LOW
HIGH
HIGH
2000
2000
[944]
[944]
0.5 [.12]
0.5 [.12]
30-60
35-65
[16.7-33.3]
[19.4-36.1]
35-65
25-55
[19.4-36.1]
[13.9-30.6]
180
180
[82.2]
[82.2]
(2) 14 x 20
(2) 14 x 20
[356 x 508]
[356 x 508]
120
140
[54]
[63]
80.0%
80.0%
M
E
Blower
Heating & Cooling
Designation
Designation
E = 1100-1330 CFM
[279 x 152 mm]
[519-628 L/s]
J = 1800-2075 CFM
[279 x 178 mm]
[850-979 L/s]
[279 x 254 mm]
15EARJR
15NARJR
150,000 [44]
121,550 [35]
105,000 [30]
84,000 [24]
.20 [.05]
11 x 10
[279 x 254]
3
/
[559]
4
4-PSC
9.5
MED-HIGH
LOW
HIGH
2000
[944]
0.5 [.12]
50-80
[27.8-44.4]
30-60
[16.7-33.3]
190
[87.7]
(2) 14 x 20
[356 x 508]
150
[68]
80.0%
R
Fuel Type
R = Natural Gas,
U.S. and
Canadian
Standard
Furnace
3

Advertisement

loading

This manual is also suitable for:

Classic plus 05nauerClassic plus 07eamerClassic plus 07namerClassic plus 10eamerClassic plus 10namerClassic plus 10ebrjr ... Show all