4.2 LC72362N-9B39 (IC701) : Micon
• Pin layout
24 - 1
25
40
41 - 64
• Pin functions
Pin
Symbol
I/O
No.
1
XIN
I Crystal oscillator
2
GND
- To GND
3
J BUS SI
I Bus serial data input from CP751
4
J BUS SO
O Bus serial data output to CP751
5
J BUS SCK
O Bus serial clock output to CP751
6
J BUS I/O SEL
O BUS I/O switch signal output
7
NC
- Non connect
8
LCD SO
O Serial data output to IC651
9
LCD SCK
O Serial clock output to IC651
10
LCD CE
O Chip enable output to IC651
11
NC
- Non connect
12
E.VOL SO
O Serial data output
13
E.VOL SCK
O Serial clock output
14
CE
- Chip enable output
15
TUNER ILLUM
- Non connect
16
TAPE ILLUM
- Non connect
17
CD ILLUM
- Non connect
18
DIMMEROUT
- Non connect
19
NC
- Non connect
20
NC
- Non connect
21
NC
- Non connect
22
NC
- Non connect
23
NC
- Non connect
24
NC
- Non connect
25
KS1
- Non connect
26
KS0
O Initializing output port
27
K3
I Initializing input port
28
K2
I Initializing input port
29
K1
- Non connect
30
K0
I Initializing input port
31
Vdd
- Power supply
32
TEST
I Test iput
33
NC
- Non connect
34
SEEK/STOP
O Output the "If signal request"
35
MONO
O Monaural and stereo change over
36
R/T
- Non connect
37
NC
- Non connect
38
POWER CNT
O Power control output
39
NC
- Non connect
40
NC
- Non connect
41
IF CONT
- Non connect
42
NC
- Non connect
80
64
Function
output
Pin
Symbol
I/O
No.
43
NC
- Non connect
44
NC
- Non connect
45
NC
- Non connect
46
NC
- Non connect
47
NC
- Non connect
48
TAPE IN
I H:RADIO L:TAPE
49
F/R SENCE
I FORWARD/REVERSE switch de-
tector
50
TAPE MUTE
I DIR.FF/REW.MUTE
51
SD/ST
I Station detector and ST input
52
NC
- Non connect
53
DETACH
I Detection of Front Panel
54
NC
- Non connect
55
J BUS INT
I BUS interruption signal detection
communication
56
REMOCON
- TO GND
57
FM/AM
I Change over the FM/AM iuput
58
DOLBY
- Non connect
59
NC
- Non connect
60
MUTE
- The mute time is controlled by the
connected
61
MEMORY DET
I Memory detector input
62
LEVEL METER
I -----
63
SMETER
I Signal meter input
64
KEY 2
I Momentary key input
65
KEY 1
I Momentary key input
66
KEY 0
I Momentary key input
67
ACCDET
I ACC DET
68
SENS
- To GND
69
NC
I Non connect
70 FM/AM IF COUNT - AM/FM Frequency detection
71
NC
- Non connect
72
NC
- Non connect
73
Vdd
I Power supply
74
AM OSC
I Input the local oscillator signal of
AM
75
FM OSC
- Input the local oscillator signal of
FM
76
Vss
- Power supply
77
NC
- Non connect
78
EO
- PLL Error signal output
79
TEST 1
O To GND
80
XOUT
O Crystal oscillator
KS-FX222