8. REC L Level Adjustment (VC-195 board)
Set the recording levels of the REC AFM signal and REC ATF signal.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, or SP/LP will not be discriminated properly. If too
high, color beets will be produced on the self-recording/playback
image.
Mode
VTR recording (SP mode)
Signal
No signal
Pin !º of CN910 (REC RF)
Measurement Point
Measuring Instrument Oscilloscope
(20MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
5B to 64
Specified Value
A = 11.0±0.7mV
Note 1: Do not insert a plug into the AUDIO (R) terminal.
Connection:
1) Remove C085 (0.01µF, Pin !§ of IC202).
Note: After completing "REC L Level Adjustment" and "REC C
Current Adjustment", replace C085 with new parts (1-162-
970-11 CERAMIC CHIP 0.01µF 10% 25V).
Preparations:
1) Insert Hi8 ME tape.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to "1". (Refer to "3. Bit value discrimination"
of "3-1-8. Service mode").
4) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to "0".
5) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin 6 of CN935 of DD-105 board
and GND with 4.7kΩ resistor for a second.)
4.7kΩ resistor: 1-249-425-11
Adjusting method:
1) Insert Hi8 ME tape, set to recording mode. (Refer to
"Preparations".)
2) Select page: 0, address: 01, and set data: 01.
3) Select page: F, address: 5B, set data: FF, and press the PAUSE
button of the adjusting remote commander.
4) Select page: F, address: 65, set data: 00, and press the PAUSE
button of the adjusting remote commander.
5) Select page: F, address: 5C, change the data and set the REC
AFM signal level (A) to the specified value.
6) Press the PAUSE button of the adjusting remote commander.
7) Select page: F, address: 5C, read the data (D
8) Calculate the adjustment data (hexadecimal) from the following
equations (hexadecimal calculation), and input each adjustment
address. (Refer to Table 5-1-2. Hexadecimal-Decimal
conversion Table.)
Address: 5B
D
5B
Address: 5D
D
5D
Address: 5E
D
5E
Address: 5F
D
5F
Address: 60
D
60
Address: 61
D
61
Address: 62
D
62
Note: After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
).
5C
= D
5C
= D
5C
= D
5C
= D
+ 12
5C
= D
+ 12
5C
= D
+ 12
5C
= D
+ 12
5C
9) Write the following data in page: F, address: 63 to 64.
Address
Data
63
64
Note: After setting each data, be sure to press the PAUSE button
of the adjusting remote commander.
10) Select page: 0, address: 01, and set data: 00.
11) Perform "REC C Current Adjustment".
Processing after completed adjustment:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, and set the data memorized at step
3) of "Preparations".
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: D, address: 15, and set the data memorized at step
4) of "Preparations".
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
5-47
7A
7A
Fig. 5-3-13.