RXD-402/452/502/552/572S/A41/A51
CD player adjustment
No.
ITEM
SETTING
Step 1,2 are in TEST MODE
TEST MODE : While pressing the [CD PALY] key, plug the AC power cord into the AC power wall outlet.
LASER
1
POWER
FOCUS
Test disc
2
ERROR
BIAS
Note:
Type 4disc :SONY YEDS-18 Test Disc or equivalent. (KTD-02)
LPF : Around 47k½ + 390pF or so.
(a) Laser Power
Pickup
(d)
RF signal F AC coupled
RF signal in test mode (PLAY).
Perform the tangential and focusing offset are focused
into one point on the display. The crossing points above
and below the center shall also be looked clearly.
12
ADJUSTMENT
INPUT
OUTPUT
SETTING
Set the senor section
of the optical power
meter on the pickup
lens.
Connect an oscillo-
scope as follows.
CH1 : RF
Type 4
CH2 : FE1
GND : VC
0.05~0.15 mW
Optical power meter
PLAYER
ALIGNMENT
SETTING
POINT
Press the"PLAY"key
to check that the dis-
play is "03".
Press the "PLAY"
FE
key. Confirm that the
BIAS VR1
display is"05"
(b) Test point
RF FE1 FE2
TE2 TE1 VC
VR1
FE. B
ALIGN FOR
On the power
from.0.05 to 0.15mw.
when the diffraction
grating is correctly
aligned with the RF
level of 0.8Vp-p or
more
Optimum eye pattern
(DC=±330mV)
X13 FOIL SIDE VIEW
FIG.
(a)
(b)
(d)