9. Flow Chart of Troubleshooting

9-1. Power On
' Power On ' does not work
Check the Battery Voltage
U400 pin J1(PONKY\)
(R713)= 0V? when END KEY
Check the Clock at
OSC400(TP402) = 32.768KHz
C423(VCORE_1.2V) = 1.24V?
C426(VMEM_1.8V) = 1.8V
C420(VBB_D_2.9V) = 2.9V?
C411(VDD_1.2V) = 1.2V?
C403(VCXOPWR_2.8V) = 2.8V?
TA400(V_BATT) > 3.3V?
Check for the clock at
TCX200(R209) = 26MHz
Check the initial operation
Yes
is more than 3.3V
Yes
is pushed.
Yes
Yes
Yes
Yes
Yes
Yes
END
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
No
Change the Battery
No
Check the U400 related to
PONKY\(ON_KEY)
No
Resolder OSC400
No
Check the U400
No
Check the U400 and BTC400
No
Check the TCX200 and U200