Philips XENIUM 9@9w Service Manual page 22

Hide thumbs Also See for XENIUM 9@9w:
Table of Contents

Advertisement

8.2.8
PCN Specification (1800 Mhz)
Test parameter
ÉMISSION
Phase error RMS
Phase error Peak
Frequency Error
Power Ramping
Modulation
Switching Transients
Timing Advance
Power reading
Output Power
RECEPTION
Rx Level
Rx Qual
Rx Level
Rx Qual
Rx Level
Rx Qual
TCH LOOP
SENSITIVITY
BER
FER
BER
FER
If a phone is out of the specifications, it must be sent to the Repair Centre.
Channel
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
Level
Standard specifications
0,5,10
0 to 5 degree
0,5,10
-20 to +20 degree
0,5,10
-180 Hz to + 180 Hz
0,5,10
0,5,10
0,5,10
0,5,10
Level 0
30 +/- 2 dBm
Level 10
10 +/- 4.0 dBm
Level 15
0 +/- 5.0 dBm
-102dbm
-102dbm
-85dbm
-85dbm
-60dbm
-60dbm
-85dbm
-85dbm
-102dbm
-102dbm
Mask
Mask
Mask
+/- 1.00 bit
4 to 12
0 to 1
21 to 29
0
46 to 54
0
0%
0%
2.44%
0%

Advertisement

Table of Contents
loading

Table of Contents