Technical Specifications - Maretron Run Indicator Module RIM100 User Manual

Run indicator module
Table of Contents

Advertisement

5 Technical Specifications

As Maretron is constantly improving its products, all specifications are subject to change
without notice. Maretron products are designed to be accurate and reliable; however, they
should be used only as aids to navigation and not as a replacement for traditional navigation
aids and techniques.
Specifications
Parameter
"ON" Voltage Range (DC)
"ON" Voltage Range (AC)
Certifications
®
NMEA 2000
Standard
Maritime Navigation and Radiocommunication Equipment & Systems
Maritime Navigation and Radiocommunication Equipment & Systems
FCC and CE Mark
®
NMEA 2000
Parameter Group Numbers (PGNs)
Description
Periodic Data PGNs
Response to Requested
PGNs
Protocol PGNs
Maretron Proprietary PGNs
Electrical
Parameter
Operating Voltage
Power Consumption
Load Equivalence Number (LEN)
Reverse Battery Protection
Load Dump Protection
Mechanical
Parameter
Size
Weight
Revision 1.0
Value
9VDC to 240VDC
9VAC to 240VAC
Parameter
PGN #
127501
Binary Switch Bank Status
126464
PGN List (Transmit and Receive)
126996
Product Information
126998
Configuration Information
059392
ISO Acknowledge
059904
ISO Request
060928
ISO Address Claim
065240
ISO Address Command
126208
NMEA Request/Command/Acknowledge
126720
Configuration
Value
9 to 32 Volts
50 mA
1
Yes
Yes
Value
3.50" x 4.20" x 2.03"
(88.9mm x 106.7mm x 51.6mm)
13 oz. (368.5 g)
RMS
Level A
IEC 61162-3
IEC 60945
Electromagnetic Compatibility
PGN Name
DC Voltage
®
NMEA 2000
®
NMEA 2000
Indefinitely
Energy Rated per SAE J1113
Including Flanges for Mounting
Comment
Comment
Default Rate
1 time/15 seconds and on
switch change
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Comment
Interface
Spec. (1LEN = 50 mA)
Comment
Page 9
® ®

Advertisement

Table of Contents