Setup; Plc Setting - Marantz ZC4001 User Manual

Audio client
Hide thumbs Also See for ZC4001:
Table of Contents

Advertisement

SETUP

PLC SETTING

RECALIBRATION
If audio is lost when the ZC4001 and ZR6001 are
connected over a PLC connection, recalibrate the
signal to the best carrier frequency.
The ZR6001 is set first.
<ZR6001>
Using the OSD menu system, set "MULTI PLC
SERVER" to "ON".
ZR6001 ON SCREEN DISPLAY MENU SYSTEM
9 MU L T I
P L C
MU L T I
P L C S E R V E R : ON
CONN E C T I ON MOD E :
AU T O
H I GH AUD I O QUA L I T Y
H I GH R E L I AB I L I T Y
GP
I D S E T T I NG : S T AR T
MA I N
E X I T
1.
Select "9. MULTI PLC" in the SETUP MAIN
MENU with the
or
cursor buttons, and
press the ENTER button.
2.
Select "MULTI PLC SERVER" with the
cursor buttons. And select "ON" with the
cursor buttons.
For details, see page 24 in the ZR6001 User's
Guide.
6
<ZC4001>
1. 2.
1
.
1.
Press and hold the ENTER button for 5 sec. or
more.
2.
Press the ENTER button.
3.
T h e b e l o w m e s s a g e a p p e a r s w h e n
or
recalibration is complete.
or
SET GROUP ID
To set a Group ID, connect the AC power cables of
the ZC4001 and ZR6001 to wall power outlets as
close to each other as possible.
Set the Group ID simultaneously for the ZC4001
and ZR6001.
<ZR6001>
Using the OSD menu system, set "GP-ID
SETTING" to "START".
ZR6001 ON SCREEN DISPLAY MENU SYSTEM
ZR6001 ON SCREEN DISPLAY MENU SYSTEM
ZR6001 ON SCREEN DISPLAY MENU SYSTEM
ZR6001 ON SCREEN DISPLAY MENU SYSTEM
ZR6001 ON SCREEN DISPLAY MENU SYSTEM
9 MU L T I
P L C
MU L T I
P L C S E R V E R : ON
CONN E C T I ON MOD E :
AU T O
H I GH AUD I O QUA L I T Y
H I GH R E L I AB I L I T Y
GP
I D S E T T I NG : S T AR T
MA I N
E X I T
1.
Select "9. MULTI PLC" in the SETUP MAIN
MENU with the
or
cursor buttons, and
press the ENTER button.
2.
Select "GP-ID SETTING" with the
cursor buttons.
<ZC4001>
1. 3. 2.
1
.
1.
Press and hold the ENTER button for 5 sec. or
more.
2.
Press the
button once.
3.
Simultaneously press the ENTER buttons of
the ZR6001 and ZC4001.
<ZR6001>
GP-ID SETTING : **
<ZC4001>
The below message appears when the Group ID
has been successfully set.
<ZC4001>
<ZR6001>
GP-ID SETTING : SUCCEED
The below message appears if the units fail to set
or
the Group ID.
<ZC4001>
<ZR6001>
GP-ID SETTING : MISSING
Notes:
One possible reason the Group ID cannot be set is
power line noise. In that case, unplug the power
cable of the device that is generating noise, then
plug it back in and try setting the Group ID again.

Advertisement