Important!
To ensure that you gain the most from your purchase, please
take a few minutes to read through this manual before lighting
the appliance for the first time.
Since April 2002 only registered competent installers can install solid
fuel appliances. Installations carried out by non-registered installers
must be inspected by local authority building control.
For more information please contact hetas at: www.hetas.co.uk or
telephone: 0845 6345626
• The installation of this appliance must
comply with current Building
Regulations and local regulations,
including those referring to national
and European standards need to be
complied with when installing the
appliance.
• Do not operate this appliance if it
becomes damaged.
• Improper use, maintenance or fitting
parts other than those approved by
the manufacturer could lead to the
appliance becoming damaged or
unsafe which in turn could lead to
personal injury or damage to the
property and will void the warranty.
• The appliance must not be modified in
anyway unless authorized by ACR
Heat Products Ltd.
Before installation, please ensure that the correct model has been supplied.
Please make a note of the serial number of your appliance in the space
provided on the front cover of this manual as this will be requested if you
require technical assistance in the future.
Please also ensure that the commissioning checklist at the rear of the manual
is completed in full.
• The appliance should be inspected
regularly to ensure the airways are
clean and free from obstruction and
the chimney swept at least once a
year.
• The external surfaces of this
appliance will be very hot to the touch
when in operation and due care will
need to be taken when operating the
appliance to ensure safety. A fire
guard should be fitted if it is likely that
the elderly, infirm or children may
come into contact with the appliance.
• This appliance must not be used as
an incinerator.
• This appliance has been designed for
intermittent operation.
Oakdale Specifications
Nominal heat output
Chimney draft required
Height
Width
Depth
Weight
Air Requirement
Flue Mass Gas Flow
2
CO @ 13% O
Mean Flue Gas Temperature
Efficiency
Log Length
*** Please note that Building Regulations Document J advises that additional permanent air supply is
required for appliances with an output of above 5Kw.
With modern properties additional air may be required as Document J suggests that adequate air
would be a benefit.
• If design air permeability ≥5.0m³/ (h.m²) then 550mm²/kW of appliance rated output above 5kW
Or
• If design air permeability ≤5.0m³/ (h.m²) then 550mm²/kW of appliance rated output
• If in doubt, please consult your registered installer for advice.
NOTE: DO NOT INSTALL IN A ROOM CONTAINING AN EXTRACTOR FAN
440
5 kW - Wood
5 kW – Smokeless Fuel
12Pa
550 mm
440 mm
370 mm
90 kg
N/A ***
3.4g/s - Wood
4.7g/s - Smokeless Fuel
0.08 vol %
274°C - Wood
273°C - Smokeless Fuel
78.3% - Wood
81.5% - Smokeless Fuel
Up To 300 mm
370