Advertisement

Multifuel Cast Iron Stove • Model FB1MF
To be retained by the user for future reference
Thank you for purchasing an ACR Heat Products stove
MULTI
FUEL
DEFRA
APPROVED
AIRWASH
SYSTEM
5
5
YEAR
YEAR
WARRANTY
Serial Number:
Document FB1MF 0101 • Version 1 Date 03/03/14
Oakdale

Advertisement

Table of Contents
loading

Summary of Contents for ACR Heat Products Oakdale FB1MF

  • Page 1 Oakdale Multifuel Cast Iron Stove • Model FB1MF To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove MULTI FUEL DEFRA APPROVED AIRWASH SYSTEM YEAR YEAR WARRANTY Serial Number: Document FB1MF 0101 • Version 1 Date 03/03/14...
  • Page 2 Important! Oakdale Specifications Nominal heat output 5 kW - Wood 5 kW – Smokeless Fuel Chimney draft required 12Pa To ensure that you gain the most from your purchase, please Height 550 mm take a few minutes to read through this manual before lighting Width 440 mm the appliance for the first time.
  • Page 3: The Clean Air Act 1993 And Smoke Control Areas

    The Clean Air Act 1993 and Smoke Control Areas Installation Instructions Under the Clean Air Act local authorities that appliances used to burn solid fuel Location of the unit Hearth Requirements may declare the whole or part of the in those areas (other than "authorised" The appliance must stand on a level Clearances to non- fuels) have been exempted by an Order...
  • Page 4: Assembly Of The Unit

    Assembly of the unit Operating your stove Please note that during the first firing, Recommended Fuels This appliance is equipped with a pre-fitted manufacturers smoke exempt stop. Under no circumstances should it be tampered with or we recommend a small fire is lit and Wood: hardwood such as ash, oak and removed unless expressly authorized by a competent person and the that you slowly increase the...
  • Page 5: Instructions For Use With Smokeless Fuel

    Operating your stove Operating your stove Instructions for use with • The burning rate can be altered by • When the fire is burning fiercely, after a Operation with door left open couple of minutes add more moving the secondary air slider Operation with the door open can cause wood smokeless fuel and close the door.
  • Page 6: Troubleshooting

    Troubleshooting Problem Probable Cause Action Recommend Fire difficult to • Green wood / wet wood Use hardwood logs with a maximum start / goes out moisture content of 20% • Logs are too large Use kindling and small logs to start the fire and once established use split logs •...
  • Page 7: Parts Information

    Diagram No. Part No. Description Parts Information 03.09244.005 BOTTOM PLATE 03.05634.005 ASH LIP 03.00395.002 FLUE COLLAR 03.52269.005 03.37696.002 AIR TUNNEL 03.02476.005 BACK PLATE 03.15366.005 COVER TOP PLATE 03.07216.002 LOCKING PLATE 03.79287.005 SIDE LEFT 03.03198.005 COVER PLATE 03.79290.005 SIDE RIGHT 03.24473.005 FRONT 03.37105.002 AIR DEFLECTOR...
  • Page 8: Warranty Information

    (if not installed by a registered competent installer) Dealer Name and address: In the unlikely event of a warranty claim, please return the above claim form to: ACR Heat Products Limited, Unit 1, Weston Works, Weston Lane, Tyseley, Birmingham, B11 3RP, England. • Tel: 0121 706 8266 •...
  • Page 9 ACR Heat Products Limited, Unit 1, Weston Works, Weston Lane, Tyseley Birmingham B11 3RP, England. • Tel: 0121 706 8266 • Fax: 0121 706 9182 • E-mail: enquiries@acrheatproducts.co.uk • www.acrheatproducts.co.uk...