Schematic Diagram - Electrolux E30SO75FPSA Service Manual

Hide thumbs Also See for E30SO75FPSA:
Table of Contents

Advertisement

E30SO75FPSA
(REHEAT, POPCORN, COOK, DEFROST)
Microwave options of Automatic cooking will automatically
compute the microwave power, cooking time or defrosting
time. And the oven will cook according to the special cook-
ing sequence.
FIRE SENSING FEATURE (MICROWAVE MODE)
This model incorporates a sensing feature which will stop
the oven's operation if there is a fire in the oven cavity
during microwave cooking. This fire sensing feature will
operate when the microwave power level is set to 80% or
more. This is accomplished by the LSI repeatedly measur-
ing the voltage across the temperature measurement circuit
(thermistor) during it's 32-seconds time base comparing the
obtained voltage measurements. If the most recent volt-
age measured is 300 mV greater than the previous voltage
measured, the LSI judges it as a fire in the oven cavity and
switches off the relays to the power transformer, fan motor
and convection motor. The LSI also stops counting down
and closes the damper door so that no fresh air will enter
the oven cavity. Please refer to the following section for a
more detailed description.
Operation
Please refer to the timing diagrams below.
. The fire sensing will start after 30 minutes when the oven
is started.
2. The thermistor operates within a 32-seconds time
SCHEMATIC
NOTE: CONDITION OF OVEN
. DOOR CLOSED.
2. CLOCK APPEARS ON DISPLAY.
GRN
GND
NOTES:
1. Circuits / Wire Colors subject to change without notice.

SCHEMATIC DIAGRAM

NOTE: " " indicates components with potential above 250V.
RED
RED
MG.
LV TRANSFORMER
TEMP.
FUSE
BRN
TOP HEATER
THERMAL
CUT-OUT
D9
T6
T4
T1
A1
A3
T7
T3
T2
FUSE12.5A
CONTROL
UNIT
RY6
BLK
GRN
BRN
WHT
GRN
GRN
N.O.
GRY
SECONDARY
GRY
INTERLOCK
GRY
SWITCH
Figure O-1. Oven Schematic-OFF Condition
0
base and it is energized for three (3) seconds and off
for 29 seconds. Two (2) seconds after the thermistor
is energized, the voltage across the temperature
measurement circuit is sampled by the LSI and twenty
five (25) seconds after the thermistor is cut off the LSI
turns on the convection fan for three (3) seconds.
3. The above procedure is repeated. If the difference
between the first voltage measured (in step ) and the
voltage measured when the procedure is repeated (step
2) is greater than 300 mV the LSI makes the judgment
that there is a fire in the oven cavity and will switch
off the relays to the power transformer, fan motor and
convection motor. The LSI also stops counting down and
closes the damper door so that no fresh air will enter the
oven cavity.
0 2 3
CONVECTION
MOTOR
ON
OFF
3 sec.
THERMISTOR
ON
OFF
ON
Sensing
Voltage
OFF
Sensing the voltage across temperature measurement circuit.
SIDE HEATER
THERMAL
CUT-OUT
BLK
RED
BLK
SOLID-STATE RELAY
ORG
BRN
BLK
RED
SOLID-STATE RELAY
BLK
COM.
WHT
WHT
28
31 32 (sec.)
64 (sec.)
3 sec.
BLK
BLK
F10A
RED
BRN
BRN