WatchStar APOLLO AUTOMATON Instruction Booklet page 19

Table of Contents

Advertisement

0S10 SUPER caliber
CHRONOGRAPH RESET (INCL. AFTER REPLACING BATTERY)
This procedure should be performed when the chronograph seconds hand does not
return to zero position after the chronograph has been reset, and including after the
battery has been replaced�
1� Pull the crown out to the 2nd position�
2� Press Button A to set the chronograph second hand to the zero position� The
chronograph hand can be advanced rapidly by continuously pressing Button A�
3� Once the hands have been zeroed, return the crown to the normal position�
NOTE: Do not push crown to normal position while the chronograph seconds hand
returns to zero position. It stops on the way when crown is returned to normal position,
and its position at that time is recognized as zero position.
35
Instructions and Specifications
0S10 SUPER caliber
Ligne
13-1/2
Diameter
ø30�80mm
Total Thickness
4�13mm
Hands
3 (H/M/S) at center
Vibration Frequency
32,768Hz
Accuracy
±20 seconds / month worn under normal circumstances
Battery Life
Approx� 3 years*
Battery
Silver oxide SR927W or equivalent
Chronograph
1/1 sec� basis
(Up to 11 hour 59 min� 59 sec�)
Additional Features
Powercell Saving Reset Mechanism (PSRM)
Over-loading Compensation Device (OLCD)
Digital Frequency Control (DFC) for time adjustment
Instructions and Specifications
(* 60 minutes chronograph operation per day)
36