These instructions are of the utmost importance in
assuring that the McCall cabinet operates as
designed. Follow them closely.
Please call your local McCall dealer or the McCall
Service Department if you have any questions regarding
proper installation.

Locating the Cabinet

When selecting a permanent location for the unit,
observe the following guidelines. Failure to do so
may cause reduced performance and efficiency,
cause damage, and/or void your warranty.
Front View
PIZZA TABLES AND
REFRIGERATED BASES
Front View
Part Number 14514 2/08
Installation Instructions
Important
! Caution
CHEF STANDS
Side View
Cabinet Clearances (Typical Single Door Cabinet Shown)
Section 2

Pre-installation Checklist

Install the cabinet in an indoor environment
only.
The air temperature entering the refrigerator or
freezer condenser should be between 55°F
(13°C) and 100°F (38°C).
Allow space for air circulation in the refrigeration
condensing unit compartment on refrigerators
and freezers. The minimum space requirements
are shown below.
The floor must be strong enough to support the
weight of the cabinet and product load.
NOTE: A fully loaded cabinet can weigh more than
2,000 pounds.
6.00"
(15.2 cm)
(Load Height)
6.00"
(15.2 cm)
1.00"
(2.5 cm)
Note:
1" side clearance
is recommended
on 27" and 45"
freezers.
No side clearance
is needed on
refrigerators.
Front View
6.00"
(15.2 cm)
(Load Height)
Side View
COMPACT UNDERCOUNTERS
REFRIGERATOR AND FREEZERS
1.00"
(2.5 cm)
Side View
6.00"
(15.2 cm)
(Load Height)
3.00"
(7.6 cm)
1.00"
(2.5 cm)
Line
Cover
E-3045-B
2-1